These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

86 related articles for article (PubMed ID: 12556033)

  • 1. Effect of lipophylic salts on ise detection limit: application to calixarene-based highly efficient potassium-selective electrodes.
    Giannetto M; Mori G; Pappalardo S; Parisi MF
    Ann Chim; 2002; 92(11-12):1099-107. PubMed ID: 12556033
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of lipophilic ion-exchanger leaching on the detection limit of carrier-based ion-selective electrodes.
    Telting-Diaz M; Bakker E
    Anal Chem; 2001 Nov; 73(22):5582-9. PubMed ID: 11816591
    [TBL] [Abstract][Full Text] [Related]  

  • 3. A calixarene-based ion-selective electrode for thallium(I) detection.
    Chester R; Sohail M; Ogden MI; Mocerino M; Pretsch E; De Marco R
    Anal Chim Acta; 2014 Dec; 851():78-86. PubMed ID: 25440668
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Potentiometric evaluation of calix[4]arene anion receptors in membrane electrodes: phosphate detection.
    Kivlehan F; Mace WJ; Moynihan HA; Arrigan DW
    Anal Chim Acta; 2007 Feb; 585(1):154-60. PubMed ID: 17386660
    [TBL] [Abstract][Full Text] [Related]  

  • 5. An improved Na+-selective microelectrode for intracellular measurements in plant cells.
    Carden DE; Diamond D; Miller AJ
    J Exp Bot; 2001 Jun; 52(359):1353-9. PubMed ID: 11432954
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Calibration of potentiometric sensor arrays with a reduced number of standards.
    Kozyra A; Wiora J; Wiora A
    Talanta; 2012 Aug; 98():28-33. PubMed ID: 22939124
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Voltammetric ion-selective electrodes for the selective determination of cations and anions.
    Zhang J; Harris AR; Cattrall RW; Bond AM
    Anal Chem; 2010 Mar; 82(5):1624-33. PubMed ID: 20121252
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Rotating disk potentiometry for inner solution optimization of low-detection-limit ion-selective electrodes.
    Radu A; Telting-Diaz M; Bakker E
    Anal Chem; 2003 Dec; 75(24):6922-31. PubMed ID: 14670054
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Nanomolar detection limits of Cd²⁺, Ag⁺, and K⁺ using paper-strip ion-selective electrodes.
    Mensah ST; Gonzalez Y; Calvo-Marzal P; Chumbimuni-Torres KY
    Anal Chem; 2014 Aug; 86(15):7269-73. PubMed ID: 25023061
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Ion-pairing ability, chemical stability, and selectivity behavior of halogenated dodecacarborane cation exchangers in neutral carrier-based ion-selective electrodes.
    Peper S; Qin Y; Almond P; McKee M; Telting-Diaz M; Albrecht-Schmitt T; Bakker E
    Anal Chem; 2003 May; 75(9):2131-9. PubMed ID: 12720352
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Synthesis and characterization of monoazathiacrown ethers as ionophores for polymeric membrane silver-selective electrodes.
    Zhang J; Ding J; Yin T; Hu X; Yu S; Qin W
    Talanta; 2010 May; 81(3):1056-62. PubMed ID: 20298893
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ion selective electrode for cesium based on 5-(4'-nitrophenylazo)25,27-bis(2-propyloxy)26,28-dihydroxycalix[4]arene.
    Ramanjaneyulu PS; Singh P; Sayi YS; Chawla HM; Ramakumar KL
    J Hazard Mater; 2010 Mar; 175(1-3):1031-6. PubMed ID: 19942345
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Rational design of potentiometric trace level ion sensors. A Ag+-selective electrode with a 100 ppt detection limit.
    Ceresa A; Radu A; Peper S; Bakker E; Pretsch E
    Anal Chem; 2002 Aug; 74(16):4027-36. PubMed ID: 12199570
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Direct ion speciation analysis with ion-selective membranes operated in a sequential potentiometric/time resolved chronopotentiometric sensing mode.
    Ghahraman Afshar M; Crespo GA; Bakker E
    Anal Chem; 2012 Oct; 84(20):8813-21. PubMed ID: 22994137
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Application of nanostructured TCNQ to potentiometric ion-selective K(+) and Na(+) electrodes.
    Paczosa-Bator B; Pięk M; Piech R
    Anal Chem; 2015 Feb; 87(3):1718-25. PubMed ID: 25551547
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fabrication and characterization of a K⁺-selective nanoelectrode and simultaneous imaging of topography and local K⁺ flux using scanning electrochemical microscopy.
    Yamada H; Haraguchi D; Yasunaga K
    Anal Chem; 2014 Sep; 86(17):8547-52. PubMed ID: 25109344
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A new ion selective electrode for cesium (I) based on calix[4]arene-crown-6 compounds.
    Ramanjaneyulu PS; Kumar AN; Sayi YS; Ramakumar KL; Nayak SK; Chattopadhyay S
    J Hazard Mater; 2012 Feb; 205-206():81-8. PubMed ID: 22260754
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sophisticated design of PVC membrane ion-selective electrodes based on the mixed potential theory.
    Imoto M; Sakaki T; Osakai T
    Anal Chem; 2013 May; 85(9):4753-60. PubMed ID: 23594104
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Development and application of ion-selective electrodes in nonaqueous solutions.
    Nakamura T
    Anal Sci; 2009 Jan; 25(1):33-40. PubMed ID: 19139570
    [TBL] [Abstract][Full Text] [Related]  

  • 20. New selenite ion-selective electrodes based on 5,10,15,20-tetrakis-(4-methoxyphenyl)-21H,23H-porphyrin-Co(II).
    Ibrahim H; Issa YM; Shehab OR
    J Hazard Mater; 2010 Sep; 181(1-3):857-67. PubMed ID: 20561747
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.