166 related articles for article (PubMed ID: 12556262)
1. Evaluation of a prototypic inspiratory impedance threshold valve designed to enhance the efficiency of cardiopulmonary resuscitation.
Lurie KG; Barnes TA; Zielinski TM; McKnite SH
Respir Care; 2003 Jan; 48(1):52-7. PubMed ID: 12556262
[TBL] [Abstract][Full Text] [Related]
2. Optimizing standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve.
Lurie KG; Mulligan KA; McKnite S; Detloff B; Lindstrom P; Lindner KH
Chest; 1998 Apr; 113(4):1084-90. PubMed ID: 9554651
[TBL] [Abstract][Full Text] [Related]
3. Effects of active compression-decompression cardiopulmonary resuscitation with the inspiratory threshold valve in a young porcine model of cardiac arrest.
Voelckel WG; Lurie KG; Sweeney M; McKnite S; Zielinski T; Lindstrom P; Peterson C; Wenzel V; Lindner KH
Pediatr Res; 2002 Apr; 51(4):523-7. PubMed ID: 11919340
[TBL] [Abstract][Full Text] [Related]
4. Effects of incomplete chest wall decompression during cardiopulmonary resuscitation on coronary and cerebral perfusion pressures in a porcine model of cardiac arrest.
Yannopoulos D; McKnite S; Aufderheide TP; Sigurdsson G; Pirrallo RG; Benditt D; Lurie KG
Resuscitation; 2005 Mar; 64(3):363-72. PubMed ID: 15733767
[TBL] [Abstract][Full Text] [Related]
5. Effects of an impedance threshold valve upon hemodynamics in Standard CPR: studies in a refined computational model.
Babbs CF
Resuscitation; 2005 Sep; 66(3):335-45. PubMed ID: 16095795
[TBL] [Abstract][Full Text] [Related]
6. Incomplete chest wall decompression: a clinical evaluation of CPR performance by EMS personnel and assessment of alternative manual chest compression-decompression techniques.
Aufderheide TP; Pirrallo RG; Yannopoulos D; Klein JP; von Briesen C; Sparks CW; Deja KA; Conrad CJ; Kitscha DJ; Provo TA; Lurie KG
Resuscitation; 2005 Mar; 64(3):353-62. PubMed ID: 15733766
[TBL] [Abstract][Full Text] [Related]
7. Intrathoracic pressure regulator during continuous-chest-compression advanced cardiac resuscitation improves vital organ perfusion pressures in a porcine model of cardiac arrest.
Yannopoulos D; Nadkarni VM; McKnite SH; Rao A; Kruger K; Metzger A; Benditt DG; Lurie KG
Circulation; 2005 Aug; 112(6):803-11. PubMed ID: 16061732
[TBL] [Abstract][Full Text] [Related]
8. The effects of positive end-expiratory pressure during active compression decompression cardiopulmonary resuscitation with the inspiratory threshold valve.
Voelckel WG; Lurie KG; Zielinski T; McKnite S; Plaisance P; Wenzel V; Lindner KH
Anesth Analg; 2001 Apr; 92(4):967-74. PubMed ID: 11273935
[TBL] [Abstract][Full Text] [Related]
9. Reducing ventilation frequency combined with an inspiratory impedance device improves CPR efficiency in swine model of cardiac arrest.
Yannopoulos D; Sigurdsson G; McKnite S; Benditt D; Lurie KG
Resuscitation; 2004 Apr; 61(1):75-82. PubMed ID: 15081185
[TBL] [Abstract][Full Text] [Related]
10. Improving active compression-decompression cardiopulmonary resuscitation with an inspiratory impedance valve.
Lurie KG; Coffeen P; Shultz J; McKnite S; Detloff B; Mulligan K
Circulation; 1995 Mar; 91(6):1629-32. PubMed ID: 7882467
[TBL] [Abstract][Full Text] [Related]
11. The impedance threshold valve for adult cardiopulmonary resuscitation: a review of the literature.
Pirracchio R; Payen D; Plaisance P
Curr Opin Crit Care; 2007 Jun; 13(3):280-6. PubMed ID: 17468559
[TBL] [Abstract][Full Text] [Related]
12. Rapid induction of cerebral hypothermia is enhanced with active compression-decompression plus inspiratory impedance threshold device cardiopulmonary resusitation in a porcine model of cardiac arrest.
Srinivasan V; Nadkarni VM; Yannopoulos D; Marino BS; Sigurdsson G; McKnite SH; Zook M; Benditt DG; Lurie KG
J Am Coll Cardiol; 2006 Feb; 47(4):835-41. PubMed ID: 16487853
[TBL] [Abstract][Full Text] [Related]
13. Vasopressor response in a porcine model of hypothermic cardiac arrest is improved with active compression-decompression cardiopulmonary resuscitation using the inspiratory impedance threshold valve.
Raedler C; Voelckel WG; Wenzel V; Bahlmann L; Baumeier W; Schmittinger CA; Herff H; Krismer AC; Lindner KH; Lurie KG
Anesth Analg; 2002 Dec; 95(6):1496-502, table of contents. PubMed ID: 12456407
[TBL] [Abstract][Full Text] [Related]
14. Influence of an impedance threshold valve on ventilation with supraglottic airway devices during cardiopulmonary resuscitation in a manikin.
Genzwuerker HV; Gernoth C; Hinkelbein J; Schmidbauer W; Kerner T
Resuscitation; 2010 Aug; 81(8):1010-3. PubMed ID: 20471153
[TBL] [Abstract][Full Text] [Related]
15. Use of an inspiratory impedance threshold valve during chest compressions without assisted ventilation may result in hypoxaemia.
Herff H; Raedler C; Zander R; Wenzel V; Schmittinger CA; Brenner E; Rieger M; Lindner KH
Resuscitation; 2007 Mar; 72(3):466-76. PubMed ID: 17150297
[TBL] [Abstract][Full Text] [Related]
16. Improving the efficiency of cardiopulmonary resuscitation with an inspiratory impedance threshold valve.
Lurie K; Zielinski T; McKnite S; Sukhum P
Crit Care Med; 2000 Nov; 28(11 Suppl):N207-9. PubMed ID: 11098948
[TBL] [Abstract][Full Text] [Related]
17. Recent advances in mechanical methods of cardiopulmonary resuscitation.
Lurie KG
Acta Anaesthesiol Scand Suppl; 1997; 111():49-52. PubMed ID: 9420954
[TBL] [Abstract][Full Text] [Related]
18. Vital organ blood flow with the impedance threshold device.
Aufderheide TP; Lurie KG
Crit Care Med; 2006 Dec; 34(12 Suppl):S466-73. PubMed ID: 17114979
[TBL] [Abstract][Full Text] [Related]
19. Application of impedance threshold devices during cardiopulmonary cerebral resuscitation.
Seekins MB; Reiss AJ
J Vet Emerg Crit Care (San Antonio); 2011 Jun; 21(3):187-92. PubMed ID: 21631704
[TBL] [Abstract][Full Text] [Related]
20. Bringing back the nearly dead. The hope and the challenge.
Lurie K
Minn Med; 2002 Apr; 85(4):39-42. PubMed ID: 11975053
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]