These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
310 related articles for article (PubMed ID: 12557975)
1. Monte Carlo dose characterization of a new 90Sr/90Y source with balloon for intravascular brachytherapy. Wang R; Li XA; Lobdell J Med Phys; 2003 Jan; 30(1):27-33. PubMed ID: 12557975 [TBL] [Abstract][Full Text] [Related]
2. IVBTMC, a Monte Carlo dose calculation tool for intravascular brachytherapy. Chibani O; Li XA Med Phys; 2003 Jan; 30(1):44-51. PubMed ID: 12557978 [TBL] [Abstract][Full Text] [Related]
3. A Monte Carlo calculation of dosimetric parameters of 90Sr/90Y and 192Ir SS sources for intravascular brachytherapy. Wang R; Li XA Med Phys; 2000 Nov; 27(11):2528-35. PubMed ID: 11128305 [TBL] [Abstract][Full Text] [Related]
4. Dosimetric comparison of two 90Sr/90Y sources for intravascular brachytherapy: an EGSnrc Monte Carlo calculation. Wang R; Li XA Phys Med Biol; 2002 Dec; 47(23):4259-69. PubMed ID: 12502048 [TBL] [Abstract][Full Text] [Related]
5. Dosimetric characteristics of the Novoste Beta-Cath 90Sr/Y source trains at submillimeter distances. Roa DE; Song H; Yue N; d'Errico F; Nath R Med Phys; 2004 May; 31(5):1269-76. PubMed ID: 15191319 [TBL] [Abstract][Full Text] [Related]
6. Monte carlo parametric study of stent impact on dose for catheter-based intravascular brachytherapy with 90Sr/90Y. Ortego PM; Prieto C; Vano E Med Phys; 2004 Jul; 31(7):1964-71. PubMed ID: 15305447 [TBL] [Abstract][Full Text] [Related]
7. Dosimetric characteristics of a linear array of gamma or beta-emitting seeds in intravascular irradiation: Monte Carlo studies for the AAPM TG-43/60 formalism. Ye SJ; Parsai EI; Feldmeier JJ Med Phys; 2003 Mar; 30(3):403-14. PubMed ID: 12674241 [TBL] [Abstract][Full Text] [Related]
8. Dosimetric characterization of the M-15 high-dose-rate Iridium-192 brachytherapy source using the AAPM and ESTRO formalism. Ho Than MT; Munro Iii JJ; Medich DC J Appl Clin Med Phys; 2015 May; 16(3):5270. PubMed ID: 26103489 [TBL] [Abstract][Full Text] [Related]
9. Monte Carlo dose calculations of beta-emitting sources for intravascular brachytherapy: a comparison between EGS4, EGSnrc, and MCNP. Wang R; Li XA Med Phys; 2001 Feb; 28(2):134-41. PubMed ID: 11243335 [TBL] [Abstract][Full Text] [Related]
10. Absorbed dose assessment of cardiac and other tissues around the cardiovascular system in brachytherapy with 90Sr/90Y source by Monte Carlo simulation. Saghamanesh S; Karimian A; Abdi M Radiat Prot Dosimetry; 2011 Sep; 147(1-2):296-9. PubMed ID: 21831866 [TBL] [Abstract][Full Text] [Related]
11. Optimization of a 90Sr/90Y radiation source train stepping for intravascular brachytherapy. Miften MM; Das SK; Shafman TD; Marks LB Med Phys; 2002 Dec; 29(12):2891-6. PubMed ID: 12512724 [TBL] [Abstract][Full Text] [Related]
12. Investigation of a 90Sr/90Y source for intra-ocular treatment of wet age-related macular degeneration. Holmes SM; Micka JA; DeWerd LA Med Phys; 2009 Oct; 36(10):4370-8. PubMed ID: 19928067 [TBL] [Abstract][Full Text] [Related]
13. Monte Carlo dosimetry of a new 192Ir pulsed dose rate brachytherapy source. Karaiskos P; Angelopoulos A; Pantelis E; Papagiannis P; Sakelliou L; Kouwenhoven E; Baltas D Med Phys; 2003 Jan; 30(1):9-16. PubMed ID: 12557972 [TBL] [Abstract][Full Text] [Related]
14. Verification of absolute dose rates for intravascular brachytherapy beta sources. Piessens M; Reynaert N Phys Med Biol; 2000 Aug; 45(8):2219-31. PubMed ID: 10958190 [TBL] [Abstract][Full Text] [Related]
15. GAF film dosimetry of a tandem positioned beta-emitting intravascular brachytherapy source train. Iftimia I; Devlin PM; Chin LM; Baron JM; Cormack RA Med Phys; 2003 Jun; 30(6):1004-12. PubMed ID: 12852522 [TBL] [Abstract][Full Text] [Related]
16. Characterization of a high-dose-rate 90Sr-90Y source for intravascular brachytherapy by using the Monte Carlo code PENELOPE. Asenjo J; Fernández-Varea JM; Sánchez-Reyes A Phys Med Biol; 2002 Mar; 47(5):697-711. PubMed ID: 11931465 [TBL] [Abstract][Full Text] [Related]
17. Accuracy assessment of the superposition principle for evaluating dose distributions of elongated and curved 103Pd and 192Ir brachytherapy sources. Bannon EA; Yang Y; Rivard MJ Med Phys; 2011 Jun; 38(6):2957-63. PubMed ID: 21815369 [TBL] [Abstract][Full Text] [Related]
18. Dosimetric characterization of an 192Ir brachytherapy source with the Monte Carlo code PENELOPE. Casado FJ; García-Pareja S; Cenizo E; Mateo B; Bodineau C; Galán P Phys Med; 2010; 26(3):132-9. PubMed ID: 20034828 [TBL] [Abstract][Full Text] [Related]
19. Dose characterization in the near-source region for two high dose rate brachytherapy sources. Wang R; Li XA Med Phys; 2002 Aug; 29(8):1678-86. PubMed ID: 12201413 [TBL] [Abstract][Full Text] [Related]
20. Calibration and validation of a quality assurance system for 90Sr/90Y radiation source trains. Rosenthal P; Weber W; Förster A; Orth O; Köhler B; Seiler F Phys Med Biol; 2003 Mar; 48(5):573-85. PubMed ID: 12696796 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]