These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

109 related articles for article (PubMed ID: 12558305)

  • 1. Design of an artificial lung compliance chamber for pulmonary replacement.
    Haft JW; Bull JL; Rose R; Katsra J; Grotberg JB; Bartlett RH; Hirschl RB
    ASAIO J; 2003; 49(1):35-40. PubMed ID: 12558305
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Effect of artificial lung compliance on right ventricular load.
    Haft JW; Alnajjar O; Bull JL; Bartlett RH; Hirschl RB
    ASAIO J; 2005; 51(6):769-72. PubMed ID: 16340366
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro fluid mechanical effects of thoracic artificial lung compliance.
    McGillicuddy JW; Chambers SD; Galligan DT; Hirschl RB; Bartlett RH; Cook KE
    ASAIO J; 2005; 51(6):789-94. PubMed ID: 16340369
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pulsatile flow and oxygen transport past cylindrical fiber arrays for an artificial lung: computational and experimental studies.
    Zierenberg JR; Fujioka H; Cook KE; Grotberg JB
    J Biomech Eng; 2008 Jun; 130(3):031019. PubMed ID: 18532868
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The influence of ventricular input impedance on the hydrodynamic performance of bioprosthetic aortic roots in vitro.
    Jennings LM; Butterfield M; Walker PG; Watterson KG; Fisher J
    J Heart Valve Dis; 2001 Mar; 10(2):269-75. PubMed ID: 11297215
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Hemodynamic analysis and design of a paracorporeal artificial lung device.
    Ha RR; Wang D; Zwischenberger JB; Clark JW
    Cardiovasc Eng; 2006 Mar; 6(1):10-29. PubMed ID: 16900418
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Improved right heart function with a compliant inflow artificial lung in series with the pulmonary circulation.
    Lick SD; Zwischenberger JB; Wang D; Deyo DJ; Alpard SK; Chambers SD
    Ann Thorac Surg; 2001 Sep; 72(3):899-904. PubMed ID: 11570380
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effect of artificial lung compliance on in vivo pulmonary system hemodynamics.
    Sato H; McGillicuddy JW; Griffith GW; Cosnowski AM; Chambers SD; Hirschl RB; Bartlett RH; Cook KE
    ASAIO J; 2006; 52(3):248-56. PubMed ID: 16760712
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optional active compliance chamber performance in a pulmonary artery-pulmonary artery configured paracorporeal artificial lung.
    Alpard SK; Wang D; Deyo DJ; Smolarz CM; Chambers S; Zwischenberger JB
    Perfusion; 2007 Mar; 22(2):81-6. PubMed ID: 17708156
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Hemodynamic effects of attachment modes and device design of a thoracic artificial lung.
    Boschetti F; Perlman CE; Cook KE; Mockros LF
    ASAIO J; 2000; 46(1):42-8. PubMed ID: 10667715
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Blood flow pulsatility effects upon oxygen transfer in artificial lungs.
    Boschetti F; Cook KE; Perlman CE; Mockros LF
    ASAIO J; 2003; 49(6):678-86. PubMed ID: 14655734
    [TBL] [Abstract][Full Text] [Related]  

  • 12. An artificial lung reduces pulmonary impedance and improves right ventricular efficiency in pulmonary hypertension.
    Haft JW; Montoya P; Alnajjar O; Posner SR; Bull JL; Iannettoni MD; Bartlett RH; Hirschl RB
    J Thorac Cardiovasc Surg; 2001 Dec; 122(6):1094-100. PubMed ID: 11726884
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Design and in vitro assessment of an improved, low-resistance compliant thoracic artificial lung.
    Schewe RE; Khanafer KM; Arab A; Mitchell JA; Skoog DJ; Cook KE
    ASAIO J; 2012; 58(6):583-9. PubMed ID: 23103694
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Thoracic artificial lung impedance studies using computational fluid dynamics and in vitro models.
    Schewe RE; Khanafer KM; Orizondo RA; Cook KE
    Ann Biomed Eng; 2012 Mar; 40(3):628-36. PubMed ID: 22009316
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Vascular impedance analysis in dog lung with detailed morphometric and elasticity data.
    Gan RZ; Yen RT
    J Appl Physiol (1985); 1994 Aug; 77(2):706-17. PubMed ID: 8002518
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Extraction of pulmonary vascular compliance, pulmonary vascular resistance, and right ventricular work from single-pressure and Doppler flow measurements in children with pulmonary hypertension: a new method for evaluating reactivity: in vitro and clinical studies.
    Weinberg CE; Hertzberg JR; Ivy DD; Kirby KS; Chan KC; Valdes-Cruz L; Shandas R
    Circulation; 2004 Oct; 110(17):2609-17. PubMed ID: 15492299
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Hemodynamic design requirements for in-series thoracic artificial lung attachment in a model of pulmonary hypertension.
    Akay B; Foucher JA; Camboni D; Koch KL; Kawatra A; Cook KE
    ASAIO J; 2012; 58(4):426-31. PubMed ID: 22581034
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Computer simulation of respiratory impedance and flow transfer functions during high frequency oscillations.
    Peslin R
    Br J Anaesth; 1989; 63(7 Suppl 1):91S-94S. PubMed ID: 2611083
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Testing of an intrathoracic artificial lung in a pig model.
    Cook KE; Makarewicz AJ; Backer CL; Mockros LF; Przybylo HJ; Crawford SE; Hernandez JM; Leonard RJ; Mavroudis C
    ASAIO J; 1996; 42(5):M604-9. PubMed ID: 8944952
    [TBL] [Abstract][Full Text] [Related]  

  • 20. An intrapleural lung prosthesis: rationale, design, and testing.
    Fazzalari FL; Bartlett RH; Bonnell MR; Montoya JP
    Artif Organs; 1994 Nov; 18(11):801-5. PubMed ID: 7864727
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]