These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

125 related articles for article (PubMed ID: 12565076)

  • 1. Synthetic aperture focusing for defect reconstruction in anisotropic media.
    Spies M; Jager W
    Ultrasonics; 2003 Mar; 41(2):125-31. PubMed ID: 12565076
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Defect imaging with elastic waves in inhomogeneous-anisotropic materials with composite geometries.
    Shlivinski A; Langenberg KJ
    Ultrasonics; 2007 Mar; 46(1):89-104. PubMed ID: 17258256
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Fully Noncontact Hybrid NDT for 3D Defect Reconstruction Using SAFT Algorithm and 2D Apodization Window.
    Selim H; Trull J; Delgado Prieto M; Picó R; Romeral L; Cojocaru C
    Sensors (Basel); 2019 May; 19(9):. PubMed ID: 31072063
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved optoacoustic microscopy through three-dimensional spatial impulse response synthetic aperture focusing technique.
    Turner J; Estrada H; Kneipp M; Razansky D
    Opt Lett; 2014 Jun; 39(12):3390-3. PubMed ID: 24978493
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Three-dimensional SAFT imaging for anisotropic materials using photoacoustic microscopy.
    Nakahata K; Karakawa K; Ogi K; Mizukami K; Ohira K; Maruyama M; Wada S; Namita T; Shiina T
    Ultrasonics; 2019 Sep; 98():82-87. PubMed ID: 31207475
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Application of a matched filter approach for finite aperture transducers for the synthetic aperture imaging of defects.
    Satyanarayan L; Muralidharan A; Krishnamurthy C; Balasubramaniam K
    IEEE Trans Ultrason Ferroelectr Freq Control; 2010 Jun; 57(6):1368-82. PubMed ID: 20529712
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Simulation of ultrasonic array imaging of composite materials with defects.
    Humeida Y; Pinfield VJ; Challis RE; Wilcox PD; Li C
    IEEE Trans Ultrason Ferroelectr Freq Control; 2013 Sep; 60(9):1935-48. PubMed ID: 24658724
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A SAFT Method for the Detection of Void Defect inside a Ballastless Track Structure Using Ultrasonic Array Sensors.
    Zhu WF; Chen XJ; Li ZW; Meng XZ; Fan GP; Shao W; Zhang HY
    Sensors (Basel); 2019 Oct; 19(21):. PubMed ID: 31661867
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Virtual nondestructive evaluation for anisotropic plates using Symmetry Informed Sequential Mapping of Anisotropic Green's function (SISMAG).
    Shrestha S; Banerjee S
    Ultrasonics; 2018 Aug; 88():51-63. PubMed ID: 29573588
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Generalized frequency-domain synthetic aperture focusing technique for ultrasonic imaging of irregularly layered objects.
    Qin K; Yang C; Sun F
    IEEE Trans Ultrason Ferroelectr Freq Control; 2014 Jan; 61(1):133-46. PubMed ID: 24402900
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Defect detection in anisotropic plates based on the instantaneous phase of signals.
    Prado VT; Granja SC; Higuti RT; Kitano C; Martínez-Graullera Ó; Segura LE
    IEEE Trans Ultrason Ferroelectr Freq Control; 2015 Oct; 62(10):1888-94. PubMed ID: 26470050
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Ultrasonic Defect Characterization in Heavy Rotor Forgings by Means of the Synthetic Aperture Focusing Technique and Optimization Methods.
    Fendt KT; Mooshofer H; Rupitsch SJ; Ermert H
    IEEE Trans Ultrason Ferroelectr Freq Control; 2016 Jun; 63(6):874-85. PubMed ID: 27116736
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Non-destructive laser-ultrasonic Synthetic Aperture Focusing Technique (SAFT) for 3D visualization of defects.
    Ni CY; Chen C; Ying KN; Dai LN; Yuan L; Kan WW; Shen ZH
    Photoacoustics; 2021 Jun; 22():100248. PubMed ID: 33732616
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Multi-mode laser-ultrasound imaging using Time-domain Synthetic Aperture Focusing Technique (T-SAFT).
    Ying KN; Ni CY; Dai LN; Yuan L; Kan WW; Shen ZH
    Photoacoustics; 2022 Sep; 27():100370. PubMed ID: 35646591
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Off-axis propagation of ultrasonic guided waves in thin orthotropic layers: theoretical analysis and dynamic holographic imaging measurement.
    Mukdadi OM; Datta SK; Telschow KL; Deason VA
    IEEE Trans Ultrason Ferroelectr Freq Control; 2001 Nov; 48(6):1581-93. PubMed ID: 11800121
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Frequency domain synthetic aperture focusing technique for variable-diameter cylindrical components.
    Jin H; Wu E; Han Y; Yang K; Chen J
    J Acoust Soc Am; 2017 Sep; 142(3):1554. PubMed ID: 28964058
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Analytical methods for modeling of ultrasonic nondestructive testing of anisotropic media.
    Spies M
    Ultrasonics; 2004 Apr; 42(1-9):213-9. PubMed ID: 15047288
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Performance of laser-ultrasonic F-SAFT imaging.
    Lévesque D; Blouin A; Néron C; Monchalin JP
    Ultrasonics; 2002 Dec; 40(10):1057-63. PubMed ID: 12441182
    [TBL] [Abstract][Full Text] [Related]  

  • 19. An implementation of synthetic aperture focusing technique in frequency domain.
    Stepinski T
    IEEE Trans Ultrason Ferroelectr Freq Control; 2007 Jul; 54(7):1399-408. PubMed ID: 17718329
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Quantitative evaluation of ultrasonic C-scan image in acoustically homogeneous and layered anisotropic materials using three dimensional ray tracing method.
    Kolkoori S; Hoehne C; Prager J; Rethmeier M; Kreutzbruck M
    Ultrasonics; 2014 Feb; 54(2):551-62. PubMed ID: 24008174
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.