290 related articles for article (PubMed ID: 12569589)
1. Breast boost: are we missing the target?
Benda RK; Yasuda G; Sethi A; Gabram SG; Hinerman RW; Mendenhall NP
Cancer; 2003 Feb; 97(4):905-9. PubMed ID: 12569589
[TBL] [Abstract][Full Text] [Related]
2. A computed tomography-based protocol vs conventional clinical mark-up for breast electron boost.
Bates AT; Swift CL; Kwa W; Moravan V; Aquino-Parsons C
Clin Oncol (R Coll Radiol); 2007 Jun; 19(5):349-55. PubMed ID: 17379487
[TBL] [Abstract][Full Text] [Related]
3. A phase I/II trial to evaluate three-dimensional conformal radiation therapy confined to the region of the lumpectomy cavity for Stage I/II breast carcinoma: initial report of feasibility and reproducibility of Radiation Therapy Oncology Group (RTOG) Study 0319.
Vicini F; Winter K; Straube W; Wong J; Pass H; Rabinovitch R; Chafe S; Arthur D; Petersen I; McCormick B
Int J Radiat Oncol Biol Phys; 2005 Dec; 63(5):1531-7. PubMed ID: 16198508
[TBL] [Abstract][Full Text] [Related]
4. Dosimetric comparison of conventional and forward-planned intensity-modulated techniques for comprehensive locoregional irradiation of post-mastectomy left breast cancers.
Cavey ML; Bayouth JE; Endres EJ; Pena JM; Colman M; Hatch S
Med Dosim; 2005; 30(2):107-16. PubMed ID: 15922178
[TBL] [Abstract][Full Text] [Related]
5. Dose calculations accounting for breathing motion in stereotactic lung radiotherapy based on 4D-CT and the internal target volume.
Admiraal MA; Schuring D; Hurkmans CW
Radiother Oncol; 2008 Jan; 86(1):55-60. PubMed ID: 18082905
[TBL] [Abstract][Full Text] [Related]
6. Importance of protocol target definition on the ability to spare normal tissue: an IMRT and 3D-CRT planning comparison for intraorbital tumors.
Hein PA; Gladstone DJ; Bellerive MR; Hug EB
Int J Radiat Oncol Biol Phys; 2005 Aug; 62(5):1540-8. PubMed ID: 16029816
[TBL] [Abstract][Full Text] [Related]
7. [Dosimetric evaluation of intensity-modulated tangential beam versus conventional tangential irradiation for breast cancer].
Huang XB; Jiang GL; Chen JY; Chen LF; Hu WG
Ai Zheng; 2006 Jul; 25(7):855-60. PubMed ID: 16831277
[TBL] [Abstract][Full Text] [Related]
8. Intensity-modulated radiotherapy for soft tissue sarcoma of the thigh.
Hong L; Alektiar KM; Hunt M; Venkatraman E; Leibel SA
Int J Radiat Oncol Biol Phys; 2004 Jul; 59(3):752-9. PubMed ID: 15183478
[TBL] [Abstract][Full Text] [Related]
9. CT-guided multi-catheter insertion technique for partial breast brachytherapy: reliable target coverage and dose homogeneity.
Cuttino LW; Todor D; Arthur DW
Brachytherapy; 2005; 4(1):10-7. PubMed ID: 15737901
[TBL] [Abstract][Full Text] [Related]
10. Radiotherapy confined to the tumor bed following breast conserving surgery current status, controversies, and future projects.
Polgár C; Fodor J; Major T; Takácsi-Nagy Z; Kásler M; Hammer J; Van Limbergen E; Németh G
Strahlenther Onkol; 2002 Nov; 178(11):597-606. PubMed ID: 12426670
[TBL] [Abstract][Full Text] [Related]
11. Single fraction partial breast irradiation in prone position.
Iaccarino G; Pinnaro P; Landoni V; Marzi S; Soriani A; Giordano C; Arcangeli S; Benassi M; Arcangeli G
J Exp Clin Cancer Res; 2007 Dec; 26(4):543-52. PubMed ID: 18365551
[TBL] [Abstract][Full Text] [Related]
12. Intensity-modulated arc therapy for treatment of high-risk endometrial malignancies.
Wong E; D'Souza DP; Chen JZ; Lock M; Rodrigues G; Coad T; Trenka K; Mulligan M; Bauman GS
Int J Radiat Oncol Biol Phys; 2005 Mar; 61(3):830-41. PubMed ID: 15708263
[TBL] [Abstract][Full Text] [Related]
13. Simulation of dose to surrounding normal structures in tangential breast radiotherapy due to setup error.
Prabhakar R; Rath GK; Julka PK; Ganesh T; Haresh KP; Joshi RC; Senthamizhchelvan S; Thulkar S; Pant GS
Med Dosim; 2008; 33(1):81-5. PubMed ID: 18262128
[TBL] [Abstract][Full Text] [Related]
14. Multisegmented tangential breast fields: a rational way to treat breast cancer.
Gulybán A; Kovács P; Sebestyén Z; Farkas R; Csere T; Karácsonyi G; Dérczy K; Hideghéty K; Esik O
Strahlenther Onkol; 2008 May; 184(5):262-9. PubMed ID: 18427757
[TBL] [Abstract][Full Text] [Related]
15. Persistently better treatment planning results of intensity-modulated (IMRT) over conformal radiotherapy (3D-CRT) in prostate cancer patients with significant variation of clinical target volume and/or organs-at-risk.
Fenoglietto P; Laliberte B; Allaw A; Ailleres N; Idri K; Hay MH; Moscardo CL; Gourgou S; Dubois JB; Azria D
Radiother Oncol; 2008 Jul; 88(1):77-87. PubMed ID: 18215434
[TBL] [Abstract][Full Text] [Related]
16. Calculation and prediction of the effect of respiratory motion on whole breast radiation therapy dose distributions.
Cao J; Roeske JC; Chmura SJ; Salama JK; Shoushtari AN; Boyer AL; Martel MK
Med Dosim; 2009; 34(2):126-32. PubMed ID: 19410141
[TBL] [Abstract][Full Text] [Related]
17. Impact of increasing margin around the lumpectomy cavity to define the planning target volume for 3D conformal external beam accelerated partial breast irradiation.
Cox BW; Horst KC; Thornton S; Dirbas FM
Med Dosim; 2007; 32(4):254-62. PubMed ID: 17980825
[TBL] [Abstract][Full Text] [Related]
18. An imrt technique to increase therapeutic ratio of breast irradiation in patients with early-stage left breast cancer: limiting second malignancies.
Ahmed RS; De Los Santos JF; Fiveash JB; Keene KS; Popple RA
Med Dosim; 2008; 33(1):71-7. PubMed ID: 18262126
[TBL] [Abstract][Full Text] [Related]
19. A technique of partial breast irradiation utilizing proton beam radiotherapy: comparison with conformal x-ray therapy.
Bush DA; Slater JD; Garberoglio C; Yuh G; Hocko JM; Slater JM
Cancer J; 2007; 13(2):114-8. PubMed ID: 17476139
[TBL] [Abstract][Full Text] [Related]
20. Postprostatectomy target-normal structure overlap volume differences using computed tomography and radioimmunoscintigraphy images for radiotherapy treatment planning.
Su A; Blend MJ; Spelbring D; Hamilton RJ; Jani AB
Clin Nucl Med; 2006 Mar; 31(3):139-44. PubMed ID: 16495731
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]