These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

136 related articles for article (PubMed ID: 12570081)

  • 1. Monitoring for N,N-dimethylformamide and N,N-dimethylacetamide with a diffusive sampler using distilled water as an absorbent.
    Tanaka S; Nomiyama T; Miyauchi H; Nakazawa M; Yamauchi T; Yamada K; Seki Y
    AIHA J (Fairfax, Va); 2002; 63(6):726-31. PubMed ID: 12570081
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Environmental monitoring of occupational exposure to N,N-dimethylformamide: comparison between active and diffusive sampling.
    Baglioni S; Cassinelli C; Bongini G; Cenni I; Graziani N; Landini M; Tanturli G; Brabec M; Bavazzano P
    Int Arch Occup Environ Health; 2007 Jan; 80(3):228-33. PubMed ID: 16799822
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Occupational dimethylformamide exposure. 1. Diffusive sampling of dimethylformamide vapor for determination of time-weighted average concentration in air.
    Yasugi T; Kawai T; Mizunuma K; Horiguchi S; Iguchi H; Ikeda M
    Int Arch Occup Environ Health; 1992; 63(7):449-53. PubMed ID: 1577523
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Seasonal difference in percutaneous absorption of N,N-dimethylformamide as determined using two urinary metabolites.
    Tsuda Y; Miyauchi H; Minozoe A; Tanaka S; Arito H; Tsukahara T; Nomiyama T
    J Occup Health; 2014; 56(4):252-9. PubMed ID: 24826962
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A simple method for carbon disulfide monitoring using a diffusive sampler, thermal desorption and a stain tube.
    Tanaka S; Yamauchi T; Takebayashi T; Omae K; Seki Y
    Ind Health; 1997 Oct; 35(4):474-9. PubMed ID: 9348719
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Validity of different biomonitoring parameters for the assessment of occupational exposure to N,N-dimethylformamide (DMF).
    Seitz M; Kilo S; Eckert E; Müller J; Drexler H; Göen T
    Arch Toxicol; 2018 Jul; 92(7):2183-2193. PubMed ID: 29748790
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Investigation on dermal contamination among workers occupationally exposed to dimethylformamide].
    Liu DH; Tang HF; Xu CM; Cai JR; Wu H; Li WC; Qian YL
    Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2010 Jun; 28(6):433-5. PubMed ID: 21033156
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Occupational exposure to N,N-dimethylformamide in the summer and winter.
    Miyauchi H; Tsuda Y; Minozoe A; Tanaka S; Arito H; Tsukahara T; Nomiyama T
    Ind Health; 2014; 52(6):512-20. PubMed ID: 25224331
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Occupational dimethylformamide exposure. 2. Monomethylformamide excretion in urine after occupational dimethylformamide exposure.
    Kawai T; Yasugi T; Mizunuma K; Watanabe T; Cai SX; Huang MY; Xi LQ; Qu JB; Yao BZ; Ikeda M
    Int Arch Occup Environ Health; 1992; 63(7):455-60. PubMed ID: 1577524
    [TBL] [Abstract][Full Text] [Related]  

  • 10. [Influencing factors that affect the biological monitoring of workers exposed to N,N-dimethylformamide in textile coating factories].
    Chung IS; Kim JG; Choi SK; Bae JY; Lee MY
    J Prev Med Public Health; 2006 Mar; 39(2):171-6. PubMed ID: 16615273
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biological monitoring of workers exposed to N,N-dimethylformamide in the synthetic fibre industry.
    Käfferlein HU; Göen T; Müller J; Wrbitzky R; Angerer J
    Int Arch Occup Environ Health; 2000 Mar; 73(2):113-20. PubMed ID: 10741509
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A new approach for diffusive sampling based on SPME for occupational exposure assessment.
    Marín P; Periago JF; Prado C
    J Occup Environ Hyg; 2013; 10(3):132-42. PubMed ID: 23356408
    [TBL] [Abstract][Full Text] [Related]  

  • 13. N,N-dimethylformamide--influence of working conditions and skin penetration on the internal exposure of workers in synthetic textile production.
    Wrbitzky R; Angerer J
    Int Arch Occup Environ Health; 1998 Jul; 71(5):309-16. PubMed ID: 9749969
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Validation of a radial diffusive sampler for measuring occupational exposure to 1,3-butadiene.
    Carrieri M; Bartolucci GB; Paci E; Sacco P; Pigini D; Zaratin L; Cottica D; Scapellato ML; Tranfo G
    J Chromatogr A; 2014 Aug; 1353():114-20. PubMed ID: 24602307
    [TBL] [Abstract][Full Text] [Related]  

  • 15. The effects of simultaneous exposure to methyl ethyl ketone and toluene on urinary biomarkers of occupational N,N-dimethylformamide exposure.
    Chang HY; Yun YD; Yu YC; Shih TS; Lin MS; Kuo HW; Chen KM
    Toxicol Lett; 2005 Mar; 155(3):385-95. PubMed ID: 15649622
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biological monitoring of occupational exposure to N,N-dimethylformamide--the effects of co-exposure to toluene or dermal exposure.
    Yang JS; Kim EA; Lee MY; Park IJ; Kang SK
    Int Arch Occup Environ Health; 2000 Sep; 73(7):463-70. PubMed ID: 11057415
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biological monitoring of workers exposed to N-N-dimethylformamide. II. Dimethylformamide and its metabolites in urine of exposed workers.
    Lareo AC; Perbellini L
    Int Arch Occup Environ Health; 1995; 67(1):47-52. PubMed ID: 7622279
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Prioritizing Type of Industry through Health Risk Assessment of Occupational Exposure to Dimethylformamide in the Workplace.
    Lee J; Hahm M; Huh DA; Byeon SH
    Int J Environ Res Public Health; 2018 Mar; 15(3):. PubMed ID: 29533984
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [Biological limit value for occupational exposure to N, N-dimethylacetamide].
    Qian YL; Xu CM; Lu YY; Tang HF; Ruan Z; Wang H; Zhu HB; Liu DH; Zhang X
    Zhonghua Lao Dong Wei Sheng Zhi Ye Bing Za Zhi; 2012 Sep; 30(9):709-11. PubMed ID: 23257108
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Exposure to solvents in a synthetic leather manufacturing plant.
    Kuo HW; Huang YS; Lo JC; Cheng TJ; Wu MJ
    Int Arch Occup Environ Health; 2000 May; 73(4):275-80. PubMed ID: 10877034
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.