These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

194 related articles for article (PubMed ID: 12570948)

  • 1. Detection and management of an implantable cardioverter defibrillator lead failure: incidence and clinical implications.
    Ellenbogen KA; Wood MA; Shepard RK; Clemo HF; Vaughn T; Holloman K; Dow M; Leffler J; Abeyratne A; Verness D
    J Am Coll Cardiol; 2003 Jan; 41(1):73-80. PubMed ID: 12570948
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transvenous defibrillation leads: high incidence of failure during long-term follow-up.
    Dorwarth U; Frey B; Dugas M; Matis T; Fiek M; Schmoeckel M; Remp T; Durchlaub I; Gerth A; Steinbeck G; Hoffmann E
    J Cardiovasc Electrophysiol; 2003 Jan; 14(1):38-43. PubMed ID: 12625608
    [TBL] [Abstract][Full Text] [Related]  

  • 3. An algorithm to predict implantable cardioverter-defibrillator lead failure.
    Gunderson BD; Patel AS; Bounds CA; Shepard RK; Wood MA; Ellenbogen KA
    J Am Coll Cardiol; 2004 Nov; 44(9):1898-902. PubMed ID: 15519026
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Causes of ventricular oversensing in implantable cardioverter-defibrillators: implications for diagnosis of lead fracture.
    Gunderson BD; Swerdlow CD; Wilcox JM; Hayman JE; Ousdigian KT; Ellenbogen KA
    Heart Rhythm; 2010 May; 7(5):626-33. PubMed ID: 20184977
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Long-term structural failure of coaxial polyurethane implantable cardioverter defibrillator leads.
    Hauser RG; Cannom D; Hayes DL; Parsonnet V; Hayes J; Ratliff N; Tyers GF; Epstein AE; Vlay SC; Furman S; Gross J
    Pacing Clin Electrophysiol; 2002 Jun; 25(6):879-82. PubMed ID: 12137338
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Potential role of home monitoring to reduce inappropriate shocks in implantable cardioverter-defibrillator patients due to lead failure.
    Spencker S; Coban N; Koch L; Schirdewan A; Müller D
    Europace; 2009 Apr; 11(4):483-8. PubMed ID: 19103654
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Development and testing of an algorithm to detect implantable cardioverter-defibrillator lead failure.
    Gunderson BD; Gillberg JM; Wood MA; Vijayaraman P; Shepard RK; Ellenbogen KA
    Heart Rhythm; 2006 Feb; 3(2):155-62. PubMed ID: 16443529
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Inappropriate discharges of intravenous implantable cardioverter defibrillators owing to lead failure.
    Washizuka T; Chinushi M; Kazama R; Hirono T; Watanabe H; Komura S; Sugiura H; Tanabe Y; Furushima H; Fujita S; Okura Y; Aizawa Y
    Int Heart J; 2005 Sep; 46(5):909-13. PubMed ID: 16272782
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multicenter investigation of an implantable cardioverter-defibrillator algorithm to detect oversensing.
    Welte N; Strik M; Eschalier R; Mondoly P; Defaye P; Frontera A; Ritter P; Haïssaguerre M; Ploux S; Koneru J; Ellenbogen KA; Bordachar P
    Heart Rhythm; 2017 Jul; 14(7):1008-1015. PubMed ID: 28323174
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term follow-up of transvenous defibrillation leads: high incidence of fracture in coaxial polyurethane lead.
    Kitamura S; Satomi K; Kurita T; Shimizu W; Suyama K; Aihara N; Niwaya K; Kobayashi J; Kamakura S
    Circ J; 2006 Mar; 70(3):273-7. PubMed ID: 16501292
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Insulation defects in Riata implantable cardioverter-defibrillator leads.
    Sato A; Chinushi M; Iijima K; Izumi D; Furushima H
    Intern Med; 2012; 51(19):2689-94. PubMed ID: 23037457
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Inappropriate shocks in the subcutaneous ICD: Incidence, predictors and management.
    Olde Nordkamp LR; Brouwer TF; Barr C; Theuns DA; Boersma LV; Johansen JB; Neuzil P; Wilde AA; Carter N; Husby M; Lambiase PD; Knops RE
    Int J Cardiol; 2015 Sep; 195():126-33. PubMed ID: 26026928
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Downloadable software algorithm reduces inappropriate shocks caused by implantable cardioverter-defibrillator lead fractures: a prospective study.
    Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Sachanandani H; Ellenbogen KA
    Circulation; 2010 Oct; 122(15):1449-55. PubMed ID: 20876433
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Subcutaneous Implantable Cardioverter Defibrillator in Patients With Hypertrophic Cardiomyopathy: An Initial Experience.
    Weinstock J; Bader YH; Maron MS; Rowin EJ; Link MS
    J Am Heart Assoc; 2016 Feb; 5(2):. PubMed ID: 26873684
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Implantable cardioverter-defibrillator lead failure in children and young adults: a matter of lead diameter or lead design?
    Janson CM; Patel AR; Bonney WJ; Smoots K; Shah MJ
    J Am Coll Cardiol; 2014 Jan; 63(2):133-40. PubMed ID: 24140671
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Lead Integrity Alert Is Useful for Assessment of Performance of Biotronik Linox Leads.
    Steinberg C; Padfield GJ; Hahn E; Flavelle S; McILROY C; VAN Bremen O; Yeung-Lai-Wah JA; Kerr CR; Deyell MW; Tung SK; Andrade JG; Bennett MT; Bashir JG; Krahn AD; Chakrabarti S
    J Cardiovasc Electrophysiol; 2015 Dec; 26(12):1340-5. PubMed ID: 26471861
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Spectrum of issues detected by an ICD diagnostic alert that utilizes far-field electrograms: Clinical implications.
    Koneru JN; Kaszala K; Bordachar P; Shehata M; Swerdlow C; Ellenbogen KA
    Heart Rhythm; 2015 May; 12(5):957-67. PubMed ID: 25640632
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sensing lead failure in implantable defibrillators: a comparison of two commonly used leads.
    Degeratu FT; Khalighi K; Peters RW; Shorofsky SR; Gold MR
    J Cardiovasc Electrophysiol; 2000 Jan; 11(1):21-4. PubMed ID: 10695456
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Downloadable algorithm to reduce inappropriate shocks caused by fractures of implantable cardioverter-defibrillator leads.
    Swerdlow CD; Gunderson BD; Ousdigian KT; Abeyratne A; Stadler RW; Gillberg JM; Patel AS; Ellenbogen KA
    Circulation; 2008 Nov; 118(21):2122-9. PubMed ID: 18981299
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Remote implantable cardioverter defibrillator monitoring in a Brugada syndrome population.
    Sacher F; Probst V; Bessouet M; Wright M; Maluski A; Abbey S; Bordachar P; Deplagne A; Ploux S; Lande G; Jaïs P; Hocini M; Haïssaguerre M; Le Marec H; Clémenty J
    Europace; 2009 Apr; 11(4):489-94. PubMed ID: 19218576
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.