146 related articles for article (PubMed ID: 1257302)

  • 1. A thermoluminescence system for the intercomparison of absorbed dose and radiation quality of X-rays with a HVL of 0-1 to 3-0 mm Cu.
    Puite KJ
    Phys Med Biol; 1976 Mar; 21(2):216-25. PubMed ID: 1257302
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The use of precision thermoluminescence dosimetry for intercomparison of absorbed dose.
    Rossiter MJ
    Phys Med Biol; 1975 Sep; 20(3):735-46. PubMed ID: 1187775
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Absorbed dose measurements of a handheld 50 kVP X-ray source in water with thermoluminescence dosemeters.
    Soares C; Drupieski C; Wingert B; Pritchett G; Pagonis V; O'Brien M; Sliski A; Bilski P; Olko P
    Radiat Prot Dosimetry; 2006; 120(1-4):78-82. PubMed ID: 16735571
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Postal intercomparison of absorbed dose for high energy x rays with thermoluminescence dosimeters.
    Bjärngard BE; Kase KR; Rudén BI; Biggs PJ; Boyer AL; Johansson KA
    Med Phys; 1980; 7(5):560-5. PubMed ID: 6775180
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Whole-body dose and energy measurements in radiotherapy by a combination of LiF:Mg,Cu,P and LiF:Mg,Ti.
    Hauri P; Schneider U
    Z Med Phys; 2018 Apr; 28(2):96-109. PubMed ID: 28807441
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of the mean glandular dose using LiF:Mg,Ti, LiF:Mg,Cu,P, Li2B4O7:Mn and Li2B4O7:Cu TL detectors in mammography radiation fields.
    Fartaria MJ; Reis C; Pereira J; Pereira MF; Cardoso JV; Santos LM; Oliveira C; Holovey V; Pascoal A; Alves JG
    Phys Med Biol; 2016 Sep; 61(17):6384-99. PubMed ID: 27499104
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Using LiF:Mg,Cu,P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source.
    Lucas PA; Aubineau-Lanièce I; Lourenço V; Vermesse D; Cutarella D
    Med Phys; 2014 Jan; 41(1):011711. PubMed ID: 24387503
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Quality control of X-ray orthovoltage therapy units with a dual TL system.
    Zaránd P; Polgár I; Katona E
    Acta Biochim Biophys Hung; 1989; 24(4):383-92. PubMed ID: 2487013
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Verification of surface dose on patients undergoing low to medium energy X-ray therapy.
    Ferguson S; Ostwald P; Kron T; Denham J
    Med Dosim; 1995; 20(3):161-5. PubMed ID: 7576088
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Materials for thermoluminescent dose detectors and photon radiation energy detectors intended for intercomparison procedures of radiation therapy units.
    Kalmykov LZ
    Med Phys; 1994 Nov; 21(11):1715-9. PubMed ID: 7891631
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Energy response of LiF:Mg, Ti dosemeters to ISO 4037 and typical diagnostic x-ray beams in Tanzania.
    Muhogora WE; Ngoye WN; Lema US; Mwalongo D
    J Radiol Prot; 2002 Jun; 22(2):175-84. PubMed ID: 12148792
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Uncertainty analysis of absorbed dose calculations from thermoluminescence dosimeters.
    Kirby TH; Hanson WF; Johnston DA
    Med Phys; 1992; 19(6):1427-33. PubMed ID: 1461205
    [TBL] [Abstract][Full Text] [Related]  

  • 13. X-ray surface dose measurements using TLD extrapolation.
    Kron T; Elliot A; Wong T; Showell G; Clubb B; Metcalfe P
    Med Phys; 1993; 20(3):703-11. PubMed ID: 8350822
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The low energy X-ray response of the LiF:Mg:Cu:P thermoluminescent dosemeter: a comparison with LiF:Mg:Ti.
    Edwards CR; Mountford PJ; Green S; Palethorpe JE; Moloney AJ
    Br J Radiol; 2005 Jun; 78(930):543-7. PubMed ID: 15900061
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Variations in dose response with x-ray energy of LiF:Mg,Cu,P thermoluminescence dosimeters: implications for clinical dosimetry.
    Duggan L; Hood C; Warren-Forward H; Haque M; Kron T
    Phys Med Biol; 2004 Sep; 49(17):3831-45. PubMed ID: 15470908
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Experimental determination of the photon-energy dependent dose-to-water response of TLD600 and TLD700 (LiF:Mg,Ti) thermoluminescence detectors.
    Schwahofer A; Feist H; Georg H; Häring P; Schlegel W
    Z Med Phys; 2017 Mar; 27(1):13-20. PubMed ID: 26972816
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Response of LiF:Mg,Ti thermoluminescent dosimeters at photon energies relevant to the dosimetry of brachytherapy (<1 MeV).
    Tedgren AC; Hedman A; Grindborg JE; Carlsson GA
    Med Phys; 2011 Oct; 38(10):5539-50. PubMed ID: 21992372
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Determination of absorbed dose to water around a clinical HDR (192)Ir source using LiF:Mg,Ti TLDs demonstrates an LET dependence of detector response.
    Carlsson Tedgren A; Elia R; Hedtjarn H; Olsson S; Alm Carlsson G
    Med Phys; 2012 Feb; 39(2):1133-40. PubMed ID: 22320824
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dosimetric intercomparison at the Scandinavian radiation therapy centres. I. Absorbed dose intercomparison.
    Johansson KA; Mattsson LO; Svensson H
    Acta Radiol Oncol; 1982; 21(1):1-10. PubMed ID: 6283791
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Addendum to the IPEMB code of practice for the determination of absorbed dose for x-rays below 300 kV generating potential (0.035 mm Al-4 mm Cu HVL).
    Aukett RJ; Burns JE; Greener AG; Harrison RM; Moretti C; Nahum AE; Rosser KE;
    Phys Med Biol; 2005 Jun; 50(12):2739-48. PubMed ID: 15930599
    [TBL] [Abstract][Full Text] [Related]  