These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
194 related articles for article (PubMed ID: 12575597)
21. Relief of primary dysmenorrhea by transcutaneous electrical nerve stimulation. Lundeberg T; Bondesson L; Lundström V Acta Obstet Gynecol Scand; 1985; 64(6):491-7. PubMed ID: 3904321 [TBL] [Abstract][Full Text] [Related]
22. Release of endogenous opioids following transcutaneous electric nerve stimulation in an experimental model of acute inflammatory pain. Sabino GS; Santos CM; Francischi JN; de Resende MA J Pain; 2008 Feb; 9(2):157-63. PubMed ID: 17988952 [TBL] [Abstract][Full Text] [Related]
23. Transcutaneous electrical nerve stimulation at both high and low frequencies reduces primary hyperalgesia in rats with joint inflammation in a time-dependent manner. Vance CG; Radhakrishnan R; Skyba DA; Sluka KA Phys Ther; 2007 Jan; 87(1):44-51. PubMed ID: 17142641 [TBL] [Abstract][Full Text] [Related]
24. Optimal stimulation frequency of transcutaneous electrical nerve stimulation on people with knee osteoarthritis. Law PP; Cheing GL J Rehabil Med; 2004 Sep; 36(5):220-5. PubMed ID: 15626162 [TBL] [Abstract][Full Text] [Related]
25. Effects of intensity of Transcutaneous Electrical Nerve Stimulation (TENS) on pressure pain threshold and blood pressure in healthy humans: A randomized, double-blind, placebo-controlled trial. Lazarou L; Kitsios A; Lazarou I; Sikaras E; Trampas A Clin J Pain; 2009; 25(9):773-80. PubMed ID: 19851157 [TBL] [Abstract][Full Text] [Related]
26. Transcutaneous electrical nerve stimulator of 5000 Hz frequency provides better analgesia than that of 100 Hz frequency in mice muscle pain model. Hsiao HT; Chien HJ; Lin YC; Liu YC Kaohsiung J Med Sci; 2017 Apr; 33(4):165-170. PubMed ID: 28359403 [TBL] [Abstract][Full Text] [Related]
27. Comparison of post-treatment effects of conventional and acupuncture-like transcutaneous electrical nerve stimulation (TENS): A randomised placebo-controlled study using cold-induced pain and healthy human participants. Francis RP; Marchant PR; Johnson MI Physiother Theory Pract; 2011 Nov; 27(8):578-85. PubMed ID: 22007892 [TBL] [Abstract][Full Text] [Related]
30. Transcutaneous electrical nerve stimulation for the control of pain in musculoskeletal disorders. Robinson AJ J Orthop Sports Phys Ther; 1996 Oct; 24(4):208-26. PubMed ID: 8892136 [TBL] [Abstract][Full Text] [Related]
31. Effects of noninvasive electroacupuncture at Hegu (LI4) and Sanyinjiao (SP6) acupoints on dysmenorrhea: a randomized controlled trial. Wu LL; Su CH; Liu CF J Altern Complement Med; 2012 Feb; 18(2):137-42. PubMed ID: 22339102 [TBL] [Abstract][Full Text] [Related]
32. Deep tissue afferents, but not cutaneous afferents, mediate transcutaneous electrical nerve stimulation-Induced antihyperalgesia. Radhakrishnan R; Sluka KA J Pain; 2005 Oct; 6(10):673-80. PubMed ID: 16202960 [TBL] [Abstract][Full Text] [Related]
33. An investigation into the hypoalgesic effects of high- and low-frequency transcutaneous electrical nerve stimulation (TENS) on experimentally-induced blunt pressure pain in healthy human participants. Chen CC; Johnson MI J Pain; 2010 Jan; 11(1):53-61. PubMed ID: 19665936 [TBL] [Abstract][Full Text] [Related]
34. High-frequency transcutaneous electrical nerve stimulation reduces pain and cardio-respiratory parameters in an animal model of acute pain: participation of peripheral serotonin. Santuzzi CH; Neto Hde A; Pires JG; Gonçalves WL; Gouvea SA; Abreu GR Physiother Theory Pract; 2013 Nov; 29(8):630-8. PubMed ID: 23477354 [TBL] [Abstract][Full Text] [Related]
35. Low frequency TENS is less effective than high frequency TENS at reducing inflammation-induced hyperalgesia in morphine-tolerant rats. Sluka KA; Judge MA; McColley MM; Reveiz PM; Taylor BM Eur J Pain; 2000; 4(2):185-93. PubMed ID: 10957699 [TBL] [Abstract][Full Text] [Related]
36. Effects of transcutaneous electrical nerve stimulation on rats with the third lumbar vertebrae transverse process syndrome. Li H; Shang XJ; Dong QR Acupunct Med; 2015 Oct; 33(5):400-5. PubMed ID: 26104377 [TBL] [Abstract][Full Text] [Related]
37. Associating high intensity and modulated frequency of TENS delays analgesic tolerance in rats. Lima LV; Cruz KM; Abner TS; Mota CM; Agripino ME; Santana-Filho VJ; DeSantana JM Eur J Pain; 2015 Mar; 19(3):369-76. PubMed ID: 24995612 [TBL] [Abstract][Full Text] [Related]
38. High and low frequency transcutaneous electrical nerve stimulation inhibits nociceptive responses induced by CO2 laser stimulation in humans. de Tommaso M; Fiore P; Camporeale A; Guido M; Libro G; Losito L; Megna M; Puca F; Megna G Neurosci Lett; 2003 May; 342(1-2):17-20. PubMed ID: 12727307 [TBL] [Abstract][Full Text] [Related]
39. An investigation into the effects of frequency-modulated transcutaneous electrical nerve stimulation (TENS) on experimentally-induced pressure pain in healthy human participants. Chen CC; Johnson MI J Pain; 2009 Oct; 10(10):1029-37. PubMed ID: 19800566 [TBL] [Abstract][Full Text] [Related]
40. Blood flow changes in the trapezius muscle and overlying skin following transcutaneous electrical nerve stimulation. Sandberg ML; Sandberg MK; Dahl J Phys Ther; 2007 Aug; 87(8):1047-55. PubMed ID: 17578938 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]