These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

120 related articles for article (PubMed ID: 12578040)

  • 21. Radial Artery Applanation Tonometry for Continuous Noninvasive Cardiac Output Measurement: A Comparison With Intermittent Pulmonary Artery Thermodilution in Patients After Cardiothoracic Surgery.
    Wagner JY; Sarwari H; Schön G; Kubik M; Kluge S; Reichenspurner H; Reuter DA; Saugel B
    Crit Care Med; 2015 Jul; 43(7):1423-8. PubMed ID: 25844700
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Cardiac output measurement during cardiac surgery: esophageal Doppler versus pulmonary artery catheter.
    Su NY; Huang CJ; Tsai P; Hsu YW; Hung YC; Cheng CR
    Acta Anaesthesiol Sin; 2002 Sep; 40(3):127-33. PubMed ID: 12434609
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Continuous versus bolus cardiac output monitoring during orthotopic liver transplantation.
    Bao FP; Wu J
    Hepatobiliary Pancreat Dis Int; 2008 Apr; 7(2):138-44. PubMed ID: 18397847
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Instantaneous and continuous cardiac output obtained with a Doppler pulmonary artery catheter.
    Segal J; Pearl RG; Ford AJ; Stern RA; Gehlbach SM
    J Am Coll Cardiol; 1989 May; 13(6):1382-92. PubMed ID: 2703619
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Testing the safety of Baxter continuous cardiac output monitoring system.
    Lichtenthal PR; Gordan D
    J Clin Monit; 1996 May; 12(3):243-9. PubMed ID: 8823649
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of cardiac output measurement by continuous thermodilution with electromagnetometry in adult cardiac surgical patients.
    Hogue CW; Rosenbloom M; McCawley C; Lappas DG
    J Cardiothorac Vasc Anesth; 1994 Dec; 8(6):631-5. PubMed ID: 7880990
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Arterial pulse cardiac output agreement with thermodilution in patients in hyperdynamic conditions.
    Della Rocca G; Costa MG; Chiarandini P; Bertossi G; Lugano M; Pompei L; Coccia C; Sainz-Barriga M; Pietropaoli P
    J Cardiothorac Vasc Anesth; 2008 Oct; 22(5):681-7. PubMed ID: 18922423
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Analysis of the accuracy of continuous thermodilution cardiac output measurement. Comparison with intermittent thermodilution and Fick cardiac output measurement.
    Jacquet L; Hanique G; Glorieux D; Matte P; Goenen M
    Intensive Care Med; 1996 Oct; 22(10):1125-9. PubMed ID: 8923082
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Continuous thermodilution cardiac output: agreement with Fick and bolus thermodilution methods.
    Thrush D; Downs JB; Smith RA
    J Cardiothorac Vasc Anesth; 1995 Aug; 9(4):399-404. PubMed ID: 7579109
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Validation of continuous thermodilution cardiac output in critically ill patients with analysis of systematic errors.
    Medin DL; Brown DT; Wesley R; Cunnion RE; Ognibene FP
    J Crit Care; 1998 Dec; 13(4):184-9. PubMed ID: 9869545
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Validation of a continuous, arterial pressure-based cardiac output measurement: a multicenter, prospective clinical trial.
    McGee WT; Horswell JL; Calderon J; Janvier G; Van Severen T; Van den Berghe G; Kozikowski L
    Crit Care; 2007; 11(5):R105. PubMed ID: 17880692
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Flow dependency of error in thermodilution measurement of cardiac output during acute tricuspid regurgitation.
    Heerdt PM; Blessios GA; Beach ML; Hogue CW
    J Cardiothorac Vasc Anesth; 2001 Apr; 15(2):183-7. PubMed ID: 11312476
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Arterial pulse wave analysis: An accurate means of determining cardiac output in children.
    Kim JJ; Dreyer WJ; Chang AC; Breinholt JP; Grifka RG
    Pediatr Crit Care Med; 2006 Nov; 7(6):532-5. PubMed ID: 17006382
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Continuous cardiac output monitoring during adult liver transplantation: thermal filament technique versus bolus thermodilution.
    Greim CA; Roewer N; Thiel H; Laux G; Schulte am Esch J
    Anesth Analg; 1997 Sep; 85(3):483-8. PubMed ID: 9296398
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Comparison of continuous, stat, and intermittent cardiac output measurements in patients undergoing minimally invasive direct coronary artery bypass surgery.
    Singh A; Juneja R; Mehta Y; Trehan N
    J Cardiothorac Vasc Anesth; 2002 Apr; 16(2):186-90. PubMed ID: 11957168
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Lithium dilution cardiac output measurement: a clinical assessment of central venous and peripheral venous indicator injection.
    Garcia-Rodriguez C; Pittman J; Cassell CH; Sum-Ping J; El-Moalem H; Young C; Mark JB
    Crit Care Med; 2002 Oct; 30(10):2199-204. PubMed ID: 12394944
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Pulmonary artery thermodilution cardiac output vs. transpulmonary thermodilution cardiac output in two patients with intrathoracic pathology.
    Breukers RB; Jansen JR
    Acta Anaesthesiol Scand; 2004 May; 48(5):658-61. PubMed ID: 15101866
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Instantaneous and continuous cardiac output in humans obtained with a Doppler pulmonary artery catheter.
    Segal J; Nassi M; Ford AJ; Schuenemeyer TD
    J Am Coll Cardiol; 1990 Nov; 16(6):1398-407. PubMed ID: 2229792
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Comparison of two semicontinuous cardiac output pulmonary artery catheters after valvular surgery.
    Neto EP; Piriou V; Durand PG; Du Gres B; Lehot JJ
    Crit Care Med; 1999 Dec; 27(12):2694-7. PubMed ID: 10628612
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Comparison of cardiac output measured continuously by thermodilution and calculated according to Fick's principle].
    Bizouarn P; Blanloeil Y; Pinaud M
    Ann Fr Anesth Reanim; 1994; 13(5):685-9. PubMed ID: 7733518
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.