185 related articles for article (PubMed ID: 12580777)
1. Development of an implantable high-energy and compact battery system for artificial heart.
Okamoto E; Inoue T; Watanabe K; Hashimoto T; Iwazawa E; Abe Y; Chinzei T; Isoyama T; Kobayashi S; Saito I; Sato F; Matsuki H; Imachi K; Mitamura Y
Artif Organs; 2003 Feb; 27(2):184-8. PubMed ID: 12580777
[TBL] [Abstract][Full Text] [Related]
2. Numerical estimation of heat distribution from the implantable battery system of an undulation pump LVAD.
Okamoto E; Makino T; Nakamura M; Tanaka S; Chinzei T; Abe Y; Isoyama T; Saito I; Mochizuki S; Imachi K; Inoue Y; Mitamura Y
J Artif Organs; 2006; 9(2):77-83. PubMed ID: 16807809
[TBL] [Abstract][Full Text] [Related]
3. Optimum selection of an implantable secondary battery for an artificial heart by examination of the cycle life test.
Okamoto E; Watanabe K; Hashiba K; Inoue T; Iwazawa E; Momoi M; Hashimoto T; Mitamura Y
ASAIO J; 2002; 48(5):495-502. PubMed ID: 12296569
[TBL] [Abstract][Full Text] [Related]
4. Development of the undulation pump total artificial heart.
Abe Y; Chinzei T; Isoyama T; Ono T; Mochizuki S; Mabuchi K; Baba K; Matsuura H; Sun YP; Kouno A; Atsumi K; Fujimasa I; Imachi K
Artif Organs; 1997 Jul; 21(7):665-9. PubMed ID: 9212936
[TBL] [Abstract][Full Text] [Related]
5. Analysis of heat generation of lithium ion rechargeable batteries used in implantable battery systems for driving undulation pump ventricular assist device.
Okamoto E; Nakamura M; Akasaka Y; Inoue Y; Abe Y; Chinzei T; Saito I; Isoyama T; Mochizuki S; Imachi K; Mitamura Y
Artif Organs; 2007 Jul; 31(7):538-41. PubMed ID: 17584478
[TBL] [Abstract][Full Text] [Related]
6. Progress in the control system of the undulation pump total artificial heart.
Saito I; Chinzei T; Abe Y; Ishimaru M; Mochizuki S; Ono T; Isoyama T; Iwasaki K; Kouno A; Baba A; Ozeki T; Takiura K; Tohyama T; Nakagawa H; Imachi K
Artif Organs; 2003 Jan; 27(1):27-33. PubMed ID: 12534710
[TBL] [Abstract][Full Text] [Related]
7. Development of integrated electronics unit for drive and control of undulation pump-left ventricular assist device.
Okamoto E; Makino T; Inoue Y; Tanaka S; Yasuda T; Nakamura M; Saito I; Abe Y; Chinzei T; Isoyama T; Mochiizuki S; Imachi K; Mitamura Y
Artif Organs; 2006 May; 30(5):403-5. PubMed ID: 16683960
[TBL] [Abstract][Full Text] [Related]
8. Life testing of implantable batteries for a total artificial heart.
Powers RA; Wolga AE; Ochs BD; Yu LS; Kung RT
ASAIO J; 1993; 39(3):M663-7. PubMed ID: 8268621
[TBL] [Abstract][Full Text] [Related]
9. Third model of the undulation pump total artificial heart.
Abe Y; Chinzei T; Isoyama T; Ono T; Mochizuki S; Saito I; Iwasaki K; Ishimaru M; Baba A; Kouno A; Ozeki T; Tohyama T; Imachi K
ASAIO J; 2003; 49(1):123-7. PubMed ID: 12558319
[TBL] [Abstract][Full Text] [Related]
10. Progress of an electrohydraulic total artificial heart system with a separate energy converter.
Masuzawa T; Tatsumi E; Taenaka Y; Nakamura M; Endo S; Takano H; Koshiji K; Fukui Y; Murai T; Tsukahara K
ASAIO J; 1999; 45(5):471-7. PubMed ID: 10503628
[TBL] [Abstract][Full Text] [Related]
11. An implantable power supply with an optically rechargeable lithium battery.
Goto K; Nakagawa T; Nakamura O; Kawata S
IEEE Trans Biomed Eng; 2001 Jul; 48(7):830-3. PubMed ID: 11442295
[TBL] [Abstract][Full Text] [Related]
12. A transcutaneous energy transmission system with rechargeable internal back-up battery for a totally implantable total artificial heart.
Shiba K; Shu E; Koshiji K; Tsukahara K; Nakamura T; Masuzawa T; Tatsumi E; Taenaka Y; Takano H
ASAIO J; 1999; 45(5):466-70. PubMed ID: 10503627
[TBL] [Abstract][Full Text] [Related]
13. [Advances in Implantable Medical Device Battery].
Fang Y; Hou W; Zhou W; Zhang H
Zhongguo Yi Liao Qi Xie Za Zhi; 2018 Jul; 42(4):272-275. PubMed ID: 30112893
[TBL] [Abstract][Full Text] [Related]
14. Totally implantable total artificial heart and ventricular assist device with multipurpose miniature electromechanical energy system.
Takatani S; Orime Y; Tasai K; Ohara Y; Naito K; Mizuguchi K; Makinouchi K; Damm G; Glueck J; Ling J
Artif Organs; 1994 Jan; 18(1):80-92. PubMed ID: 8141662
[TBL] [Abstract][Full Text] [Related]
15. The re-design at the transformer portion of transcutaneous energy transmission system for all implantable devices.
Watada M; Saisho R; Kim YJ; Ohuchi K; Takatani S; Um YS
Annu Int Conf IEEE Eng Med Biol Soc; 2007; 2007():1035-8. PubMed ID: 18002137
[TBL] [Abstract][Full Text] [Related]
16. Selection of a rechargeable internal back-up battery for a totally implantable artificial heart.
Honda H; Shiba K; Shu E; Koshiji K; Murai T; Nakamura T; Masuzawa T; Tatsumi E; Taenaka Y; Takano H
ASAIO J; 1999; 45(4):339-43. PubMed ID: 10445742
[TBL] [Abstract][Full Text] [Related]
17. A high-performance transcutaneous battery charger for medical implants.
Artan N; Vanjani H; Vashist G; Fu Z; Bhakthavatsala S; Ludvig N; Medveczky G; Chao H
Annu Int Conf IEEE Eng Med Biol Soc; 2010; 2010():1581-4. PubMed ID: 21096386
[TBL] [Abstract][Full Text] [Related]
18. Implantable cardiac rhythm device batteries.
Root MJ
J Cardiovasc Transl Res; 2008 Dec; 1(4):254-7. PubMed ID: 20559932
[TBL] [Abstract][Full Text] [Related]
19. A new transcutaneous energy transmission system with hybrid energy coils for driving an implantable biventricular assist device.
Okamoto E; Yamamoto Y; Akasaka Y; Motomura T; Mitamura Y; Nosé Y
Artif Organs; 2009 Aug; 33(8):622-6. PubMed ID: 19769776
[TBL] [Abstract][Full Text] [Related]
20. Intelligent Li ion battery management based on a digital signal processor for a moving actuator total artificial heart.
Kim WE; Ahn JM; Choi SW; Min BG
ASAIO J; 1997; 43(5):M588-92. PubMed ID: 9360113
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]