These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

530 related articles for article (PubMed ID: 12583095)

  • 1. [A new generation of pulmonary function measuring system].
    Zeng BX; Chen SS; Huang M
    Zhongguo Yi Liao Qi Xie Za Zhi; 2000 Feb; 24(2):86-8. PubMed ID: 12583095
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Measurements of ventilation in freely ranging subjects.
    McCool FD; Paek D
    Res Rep Health Eff Inst; 1993 May; (59):1-17; discussion 57-69. PubMed ID: 8216969
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Effects of mechanical load on flow, volume and pressure delivered by high-frequency percussive ventilation.
    Lucangelo U; Antonaglia V; Zin WA; Fontanesi L; Peratoner A; Bird FM; Gullo A
    Respir Physiol Neurobiol; 2004 Aug; 142(1):81-91. PubMed ID: 15351306
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Measuring tidal breathing parameters using a volumetric vest in neonates with and without lung disease.
    Olden C; Symes E; Seddon P
    Pediatr Pulmonol; 2010 Nov; 45(11):1070-5. PubMed ID: 20872815
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [The Pulma-01 automated microprocessor system for testing external respiratory function].
    Georgiev G; Bol'shov VM; Eskin VIa; Kol'tsun SS; Valevski G
    Med Tekh; 1987; (2):18-22. PubMed ID: 3586958
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Technics for measuring pressure, flow and volume in respiratory function tests].
    Duvivier C; Peslin R; Hannhart B
    Rev Mal Respir; 1986; 3(6):449-56. PubMed ID: 3575865
    [No Abstract]   [Full Text] [Related]  

  • 7. Non-invasive measurement of total respiratory compliance and resistance in cats.
    Epstein A; Godfrey S; Bar-Yishay E; Putilov A; Bark H
    Respir Physiol Neurobiol; 2007 May; 156(2):179-86. PubMed ID: 17113363
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Daily pattern of breathing in healthy young men.
    Adamczyk W; Tafil-Klawe M; Siekierka M; Zlomanczuk P; Weber P; Klawe JJ
    J Physiol Pharmacol; 2008 Dec; 59 Suppl 6():115-22. PubMed ID: 19218635
    [TBL] [Abstract][Full Text] [Related]  

  • 9. How much lung ventilation is obtained with only chest-compression CPR?
    Geddes LA; Rundell A; Otlewski M; Pargett M
    Cardiovasc Eng; 2008 Sep; 8(3):145-8. PubMed ID: 18581233
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Instability of spontaneous breathing patterns in patients with persistent vegetative state.
    Bien MY; Yien HW; Hseu SS; Wang JH; Kou YR
    Respir Physiol Neurobiol; 2005 Feb; 145(2-3):163-75. PubMed ID: 15705532
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanical loads modulate tidal volume and lung washout during high-frequency percussive ventilation.
    Lucangelo U; Antonaglia V; Zin WA; Berlot G; Fontanesi L; Peratoner A; Bernabè F; Gullo A
    Respir Physiol Neurobiol; 2006 Jan; 150(1):44-51. PubMed ID: 16448933
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Measuring breathing pattern in patients with chronic obstructive pulmonary disease by electrical impedance tomography].
    Balleza M; Calaf N; Feixas T; González M; Antón D; Riu PJ; Casan P
    Arch Bronconeumol; 2009 Jul; 45(7):320-4. PubMed ID: 19497652
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Inert gas washout in preschool children.
    Gustafsson PM
    Paediatr Respir Rev; 2005 Dec; 6(4):239-45. PubMed ID: 16298306
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Lung volumes during +Gz acceleration and the effects of positive pressure breathing and chest counter-pressure.
    Green ND
    J Gravit Physiol; 1994 May; 1(1):P41-4. PubMed ID: 11538757
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Do new anesthesia ventilators deliver small tidal volumes accurately during volume-controlled ventilation?
    Bachiller PR; McDonough JM; Feldman JM
    Anesth Analg; 2008 May; 106(5):1392-400, table of contents. PubMed ID: 18420850
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Effect of ventilatory variables on gas exchange and hemodynamics during total liquid ventilation in a rat model.
    Matsuda K; Sawada S; Bartlett RH; Hirschl RB
    Crit Care Med; 2003 Jul; 31(7):2034-40. PubMed ID: 12847401
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Regional distribution of acoustic-based lung vibration as a function of mechanical ventilation mode.
    Dellinger RP; Jean S; Cinel I; Tay C; Rajanala S; Glickman YA; Parrillo JE
    Crit Care; 2007; 11(1):R26. PubMed ID: 17316449
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Respiratory system model for quasistatic pulmonary pressure-volume (P-V) curve: generalized P-V curve analyses.
    Amini R; Barnes TA; Savran A; Narusawa U
    J Biomech Eng; 2008 Aug; 130(4):044501. PubMed ID: 18601463
    [TBL] [Abstract][Full Text] [Related]  

  • 19. [The breathing pattern, an old friend full of information--but how do we get that information?].
    Gea J; Orozco-Levi M; Martínez-Llorens J
    Arch Bronconeumol; 2009 Jul; 45(7):317-9. PubMed ID: 19523731
    [No Abstract]   [Full Text] [Related]  

  • 20. Combining "open-lung" ventilation and arteriovenous extracorporeal lung assist: influence of different tidal volumes on gas exchange in experimental lung failure.
    Muellenbach RM; Kredel M; Kuestermann J; Klingelhoefer M; Schuster F; Wunder C; Kranke P; Roewer N; Brederlau J
    Med Sci Monit; 2009 Aug; 15(8):BR213-20. PubMed ID: 19644409
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 27.