146 related articles for article (PubMed ID: 12585592)
1. Microvascular response of striated muscle to metal debris. A comparative in vivo study with titanium and stainless steel.
Kraft CN; Diedrich O; Burian B; Schmitt O; Wimmer MA
J Bone Joint Surg Br; 2003 Jan; 85(1):133-41. PubMed ID: 12585592
[TBL] [Abstract][Full Text] [Related]
2. Impact of a nickel-reduced stainless steel implant on striated muscle microcirculation: a comparative in vivo study.
Kraft CN; Burian B; Perlick L; Wimmer MA; Wallny T; Schmitt O; Diedrich O
J Biomed Mater Res; 2001 Dec; 57(3):404-12. PubMed ID: 11523035
[TBL] [Abstract][Full Text] [Related]
3. Striated muscle microvascular response to silver implants: A comparative in vivo study with titanium and stainless steel.
Kraft CN; Hansis M; Arens S; Menger MD; Vollmar B
J Biomed Mater Res; 2000 Feb; 49(2):192-9. PubMed ID: 10571905
[TBL] [Abstract][Full Text] [Related]
4. Implications of orthopedic fretting corrosion particles on skeletal muscle microcirculation.
Kraft CN; Burian B; Diedrich O; Wimmer MA
J Mater Sci Mater Med; 2001; 12(10-12):1057-62. PubMed ID: 15348365
[TBL] [Abstract][Full Text] [Related]
5. [Systemic spread of wear debris--an in-vivo study].
Burian B; Wimmer MA; Kunze J; Sprecher CM; Pennekamp PH; von Engelhardt LV; Diedrich O; Kraft CN
Z Orthop Ihre Grenzgeb; 2006; 144(5):539-44. PubMed ID: 16991074
[TBL] [Abstract][Full Text] [Related]
6. Short-term microvascular response of striated muscle to cp-Ti, Ti-6Al-4V, and Ti-6Al-7Nb.
Pennekamp PH; Gessmann J; Diedrich O; Burian B; Wimmer MA; Frauchiger VM; Kraft CN
J Orthop Res; 2006 Mar; 24(3):531-40. PubMed ID: 16463365
[TBL] [Abstract][Full Text] [Related]
7. [Striated muscle microvascular response to implants with sol-gel calcium phosphate coating. A comparative in vivo study].
Kraft CN; Weber W; Burian B; Zander D; Wallny T; Schmitt O; Diedrich O
Z Orthop Ihre Grenzgeb; 2002; 140(6):672-80. PubMed ID: 12476392
[TBL] [Abstract][Full Text] [Related]
8. Microvascular response of striated muscle to common arthroplasty-alloys: A comparative in vivo study with CoCrMo, Ti-6Al-4V, and Ti-6Al-7Nb.
Kraft CN; Burian B; Diedrich O; Gessmann J; Wimmer MA; Pennekamp PH
J Biomed Mater Res A; 2005 Oct; 75(1):31-40. PubMed ID: 16078208
[TBL] [Abstract][Full Text] [Related]
9. Spinal implant debris-induced osteolysis.
Hallab NJ; Cunningham BW; Jacobs JJ
Spine (Phila Pa 1976); 2003 Oct; 28(20):S125-38. PubMed ID: 14560184
[TBL] [Abstract][Full Text] [Related]
10. Microvasculatory reaction of skeletal muscle to Ti-15Mo in comparison to well-established titanium alloys.
Pennekamp PH; Wimmer MA; Eschbach L; Burian B; Koch P; Kraft CN
J Mater Sci Mater Med; 2007 Oct; 18(10):2053-60. PubMed ID: 17558479
[TBL] [Abstract][Full Text] [Related]
11. Difference in metallic wear distribution released from commercially pure titanium compared with stainless steel plates.
Krischak GD; Gebhard F; Mohr W; Krivan V; Ignatius A; Beck A; Wachter NJ; Reuter P; Arand M; Kinzl L; Claes LE
Arch Orthop Trauma Surg; 2004 Mar; 124(2):104-13. PubMed ID: 14727127
[TBL] [Abstract][Full Text] [Related]
12. Comparative Analysis of NF-κB in the MyD88-Mediated Pathway After Implantation of Titanium Alloy and Stainless Steel and the Role of Regulatory T Cells.
Akyol S; Akgun MY; Yetmez M; Hanci M; Oktar FN; Ben-Nissan B
World Neurosurg; 2020 Dec; 144():e138-e148. PubMed ID: 32781150
[TBL] [Abstract][Full Text] [Related]
13. Stainless steel wear debris of a scoliotic growth guidance system has little local and systemic effect in an animal model.
Singh V; Rawlinson J; Hallab N
J Orthop Res; 2018 Jul; 36(7):1980-1990. PubMed ID: 29323741
[TBL] [Abstract][Full Text] [Related]
14. Widespread dissemination of metal debris from implants.
Case CP; Langkamer VG; James C; Palmer MR; Kemp AJ; Heap PF; Solomon L
J Bone Joint Surg Br; 1994 Sep; 76(5):701-12. PubMed ID: 8083255
[TBL] [Abstract][Full Text] [Related]
15. Biomaterial optimization in total disc arthroplasty.
Hallab N; Link HD; McAfee PC
Spine (Phila Pa 1976); 2003 Oct; 28(20):S139-52. PubMed ID: 14560185
[TBL] [Abstract][Full Text] [Related]
16. Effects of local cooling on microvascular hemodynamics and leukocyte adhesion in the striated muscle of hamsters.
Thorlacius H; Vollmar B; Westermann S; Törkvist L; Menger MD
J Trauma; 1998 Oct; 45(4):715-9. PubMed ID: 9783610
[TBL] [Abstract][Full Text] [Related]
17. The potential role of human osteoblasts for periprosthetic osteolysis following exposure to wear particles.
Lochner K; Fritsche A; Jonitz A; Hansmann D; Mueller P; Mueller-Hilke B; Bader R
Int J Mol Med; 2011 Dec; 28(6):1055-63. PubMed ID: 21850366
[TBL] [Abstract][Full Text] [Related]
18. A histologic analysis of the effects of stainless steel and titanium implants adjacent to tendons: an experimental rabbit study.
Nazzal A; Lozano-Calderón S; Jupiter JB; Rosenzweig JS; Randolph MA; Lee SG
J Hand Surg Am; 2006 Sep; 31(7):1123-30. PubMed ID: 16945714
[TBL] [Abstract][Full Text] [Related]
19. Inhibitory effects of melatonin on titanium particle-induced inflammatory bone resorption and osteoclastogenesis via suppression of NF-κB signaling.
Ping Z; Wang Z; Shi J; Wang L; Guo X; Zhou W; Hu X; Wu X; Liu Y; Zhang W; Yang H; Xu Y; Gu Y; Geng D
Acta Biomater; 2017 Oct; 62():362-371. PubMed ID: 28867647
[TBL] [Abstract][Full Text] [Related]
20. Epidural application of spinal instrumentation particulate wear debris: a comprehensive evaluation of neurotoxicity using an in vivo animal model.
Cunningham BW; Hallab NJ; Hu N; McAfee PC
J Neurosurg Spine; 2013 Sep; 19(3):336-50. PubMed ID: 23808583
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]