These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Choice of ventilation system for operating-theatres. Comparison of turbulent versus laminar-linear flow systems in operating-rooms and industrial clean rooms. Scott CC; Sanderson JT; Guthrie TD Lancet; 1971 Jun; 1(7712):1288-91. PubMed ID: 4104732 [No Abstract] [Full Text] [Related]
3. Do we really need laminar flow ventilation in the operating room to prevent surgical site infections? Lipsett PA Ann Surg; 2008 Nov; 248(5):701-3. PubMed ID: 18948794 [No Abstract] [Full Text] [Related]
4. Ventilation performance in operating theatres against airborne infection: review of research activities and practical guidance. Chow TT; Yang XY J Hosp Infect; 2004 Feb; 56(2):85-92. PubMed ID: 15019218 [TBL] [Abstract][Full Text] [Related]
5. Wound ventilation with ultraclean air for prevention of direct airborne contamination during surgery. Persson M; van der Linden J Infect Control Hosp Epidemiol; 2004 Apr; 25(4):297-301. PubMed ID: 15108726 [TBL] [Abstract][Full Text] [Related]
6. The effectiveness of ultra-clean air operating theatres in the prevention of deep infection in joint arthroplasty surgery. Thomas AM; Simmons MJ Bone Joint J; 2018 Oct; 100-B(10):1264-1269. PubMed ID: 30295523 [TBL] [Abstract][Full Text] [Related]
7. Survey of operating theatre ventilation facilities for minimally invasive surgery in Great Britain and Northern Ireland: current practice and considerations for the future. Smyth ET; Humphreys H; Stacey A; Taylor EW; Hoffman P; Bannister G J Hosp Infect; 2005 Oct; 61(2):112-22. PubMed ID: 16240467 [TBL] [Abstract][Full Text] [Related]
8. Impact of laminar air flow on operating room contamination, and surgical wound infection rates in clean and contaminated surgery. Barbadoro P; Bruschi R; Martini E; Savini S; Gioia MG; Stoico R; Di Tondo E; D'Errico MM; Prospero E Eur J Surg Oncol; 2016 Nov; 42(11):1756-1758. PubMed ID: 27554249 [No Abstract] [Full Text] [Related]
9. Surgical site infection, ultraclean ventilated operating theatres and prosthetic joint surgery: where now? Humphreys H J Hosp Infect; 2012 Jun; 81(2):71-2. PubMed ID: 22579078 [No Abstract] [Full Text] [Related]
10. Laminar-linear flow system of ventilation. Its application to medicine and surgery. Scott CC Lancet; 1970 May; 1(7654):989-93. PubMed ID: 4191945 [No Abstract] [Full Text] [Related]
11. The application value of operating room ventilation with laminar airflow for surgical site infection: A protocol for a systematic review and meta-analysis. Liu YY; Shi LY; Duan YM; Li XM Medicine (Baltimore); 2021 Aug; 100(32):e26814. PubMed ID: 34397883 [TBL] [Abstract][Full Text] [Related]
12. Protective effect of HEPA filtered operating room air ventilation with or without laminar airflow on surgical site infections. Assadian O; Kuelpmann R; Zhumadilova A; Kobayashi H; Heidecke CD; Kramer A Ann Surg; 2009 Oct; 250(4):659-60; author reply 660. PubMed ID: 19710603 [No Abstract] [Full Text] [Related]
13. Assessment of horizontal laminar air flow instrument table for additional ultraclean space during surgery. Nilsson KG; Lundholm R; Friberg S J Hosp Infect; 2010 Nov; 76(3):243-6. PubMed ID: 20846746 [TBL] [Abstract][Full Text] [Related]
14. Comparison between mixed and laminar airflow systems in operating rooms and the influence of human factors: experiences from a Swedish orthopedic center. Erichsen Andersson A; Petzold M; Bergh I; Karlsson J; Eriksson BI; Nilsson K Am J Infect Control; 2014 Jun; 42(6):665-9. PubMed ID: 24713595 [TBL] [Abstract][Full Text] [Related]
15. Laminar airflow and the prevention of surgical site infection. More harm than good? McHugh SM; Hill AD; Humphreys H Surgeon; 2015 Feb; 13(1):52-8. PubMed ID: 25453272 [TBL] [Abstract][Full Text] [Related]
16. Operating room ventilation with laminar airflow shows no protective effect on the surgical site infection rate in orthopedic and abdominal surgery. Brandt C; Hott U; Sohr D; Daschner F; Gastmeier P; RĂ¼den H Ann Surg; 2008 Nov; 248(5):695-700. PubMed ID: 18948793 [TBL] [Abstract][Full Text] [Related]
17. [Tilting at WIP windmills in the OR: laminar flow might be harmful]. de Brauw LM Ned Tijdschr Geneeskd; 2017; 161():D1745. PubMed ID: 28984214 [TBL] [Abstract][Full Text] [Related]
18. A UK historical perspective on operating theatre ventilation. Stacey A; Humphreys H; J Hosp Infect; 2002 Oct; 52(2):77-80. PubMed ID: 12392897 [TBL] [Abstract][Full Text] [Related]
19. A study of the application of laminar flow ventilation to operating rooms. Fox DG Public Health Monogr; 1969; 78():1-50. PubMed ID: 5358020 [No Abstract] [Full Text] [Related]
20. Impact of different-sized laminar air flow versus no laminar air flow on bacterial counts in the operating room during orthopedic surgery. Diab-Elschahawi M; Berger J; Blacky A; Kimberger O; Oguz R; Kuelpmann R; Kramer A; Assadian O Am J Infect Control; 2011 Sep; 39(7):e25-9. PubMed ID: 21496953 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]