These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

170 related articles for article (PubMed ID: 12594705)

  • 1. Successful treatment of distal coronary guidewire-induced perforation with balloon catheter delivery of intracoronary thrombin.
    Fischell TA; Korban EH; Lauer MA
    Catheter Cardiovasc Interv; 2003 Mar; 58(3):370-4. PubMed ID: 12594705
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Intracoronary thrombin injection using a microcatheter to treat guidewire-induced coronary artery perforation.
    Fischell TA; Moualla SK; Mannem SR
    Cardiovasc Revasc Med; 2011; 12(5):329-33. PubMed ID: 21367674
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Closure of guide wire-induced coronary artery perforation with a two-component fibrin glue.
    Störger H; Ruef J
    Catheter Cardiovasc Interv; 2007 Aug; 70(2):237-40. PubMed ID: 17420994
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Coronary artery rupture during balloon angioplasty, rescued with localized thrombin injection and coil embolization.
    Fischell TA; Carter AJ; Ashraf K; Birdsall J; Smoker S
    Catheter Cardiovasc Interv; 2006 Aug; 68(2):254-7. PubMed ID: 16819769
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Coronary perforation after percutaneous coronary intervention successfully treated with local thrombin injection.
    Jamali AH; Lee MS; Makkar RR
    J Invasive Cardiol; 2006 Apr; 18(4):E143-5. PubMed ID: 16723750
    [No Abstract]   [Full Text] [Related]  

  • 6. Successful closure of guidewire-induced coronary perforation with intracoronary thrombin injection.
    Merkel M; Riexinger T; Schmitt C
    Clin Res Cardiol; 2011 Sep; 100(9):807-8. PubMed ID: 21533582
    [No Abstract]   [Full Text] [Related]  

  • 7. Coronary vessel perforation during balloon angioplasty: a case report.
    Hadjimiltiades S; Paraskevaides S; Kazinakis G; Louridas G
    Cathet Cardiovasc Diagn; 1998 Dec; 45(4):417-20. PubMed ID: 9863750
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Guidewire-induced coronary artery perforation treated with transcatheter delivery of subcutaneous tissue.
    Oda H; Oda M; Makiyama Y; Kashimura T; Takahashi K; Miida T; Higuma N
    Catheter Cardiovasc Interv; 2005 Nov; 66(3):369-74. PubMed ID: 16208712
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Successful collapse vessel treatment with a syringe for thrombus-aspiration after the guidewire-induced coronary artery perforation.
    Yasuoka Y; Sasaki T
    Cardiovasc Revasc Med; 2010; 11(4):263.e1-3. PubMed ID: 20934662
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Gelfoam embolization of a distal coronary artery guidewire perforation.
    Dixon SR; Webster MW; Ormiston JA; Wattie WJ; Hammett CJ
    Catheter Cardiovasc Interv; 2000 Feb; 49(2):214-7. PubMed ID: 10642778
    [TBL] [Abstract][Full Text] [Related]  

  • 11. How should I treat guidewire-induced distal coronary perforation?
    Senguttuvan NB; Ramakrishnan S; Gulati GS; Seth S; Bhargava B
    EuroIntervention; 2012 May; 8(1):155-63. PubMed ID: 22580259
    [No Abstract]   [Full Text] [Related]  

  • 12. Repair of coronary artery perforation following angioplasty using TachoSil patches.
    Celiento M; Scioti G; Pratali S; Bortolotti U
    Interact Cardiovasc Thorac Surg; 2010 Feb; 10(2):328-30. PubMed ID: 19933239
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Management of guidewire-induced distal coronary perforation using autologous fat particles versus coil embolization.
    Shemisa K; Karatasakis A; Brilakis ES
    Catheter Cardiovasc Interv; 2017 Feb; 89(2):253-258. PubMed ID: 27143506
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [A case of guidewire-induced distal coronary perforation treated with microcatheter delivery of intracoronary thrombin].
    Dai S; Xu Z; Zhang J; Wang B; Liu Y; Li Y; Geng T; Yuan Y; Ma Z; Song Z; Peng W
    Zhonghua Xin Xue Guan Bing Za Zhi; 2015 Jan; 43(1):76-7. PubMed ID: 25876729
    [No Abstract]   [Full Text] [Related]  

  • 15. Successful management of a distal vessel perforation through a single 8-French guide catheter: Combining balloon inflation for bleeding control with coil embolization.
    Tarar MN; Christakopoulos GE; Brilakis ES
    Catheter Cardiovasc Interv; 2015 Sep; 86(3):412-6. PubMed ID: 25854795
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Covered stent implantation through a single 8-french guide catheter for the management of a distal coronary perforation.
    Sandoval Y; Lobo AS; Brilakis ES
    Catheter Cardiovasc Interv; 2017 Oct; 90(4):584-588. PubMed ID: 28303639
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Guidewire-induced coronary perforation successfully treated with subcutaneous fat embolisation: A simple technique available to all.
    George S; Cotton J; Wrigley B
    Catheter Cardiovasc Interv; 2015 Dec; 86(7):1186-8. PubMed ID: 26010175
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Thrombin injection for sealing epicardial collateral perforation during chronic total occlusion percutaneous coronary interventions.
    Kotsia AP; Brilakis ES; Karmpaliotis D
    J Invasive Cardiol; 2014 Sep; 26(9):E124-6. PubMed ID: 25198496
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Novel use of the Mguard mesh-covered stent to treat coronary arterial perforations.
    Romaguera R; Gomez-Hospital JA; Cequier A
    Catheter Cardiovasc Interv; 2012 Jul; 80(1):75-8. PubMed ID: 22511569
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Treatment and outcome of coronary artery perforations using a dual guiding catheter technique.
    Röther J; Tröbs M; Ludwig J; Achenbach S; Schlundt C
    Int J Cardiol; 2015 Dec; 201():479-83. PubMed ID: 26313871
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.