These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
162 related articles for article (PubMed ID: 12595980)
1. Measurement of functional residual capacity by nitrogen washout during partial ventilatory support. Zinserling J; Wrigge H; Varelmann D; Hering R; Putensen C Intensive Care Med; 2003 May; 29(5):720-6. PubMed ID: 12595980 [TBL] [Abstract][Full Text] [Related]
2. Determination of functional residual capacity (FRC) by multibreath nitrogen washout in a lung model and in mechanically ventilated patients. Accuracy depends on continuous dynamic compensation for changes of gas sampling delay time. Wrigge H; Sydow M; Zinserling J; Neumann P; Hinz J; Burchardi H Intensive Care Med; 1998 May; 24(5):487-93. PubMed ID: 9660266 [TBL] [Abstract][Full Text] [Related]
3. Measurement of functional residual capacity by modified multiple breath nitrogen washout for spontaneously breathing and mechanically ventilated patients. Brewer LM; Orr JA; Sherman MR; Fulcher EH; Markewitz BA Br J Anaesth; 2011 Nov; 107(5):796-805. PubMed ID: 21752798 [TBL] [Abstract][Full Text] [Related]
4. Evaluation of a CO2 partial rebreathing functional residual capacity measurement method for use during mechanical ventilation. Brewer L; Orr J; Fulcher E; Markewitz B J Clin Monit Comput; 2011 Dec; 25(6):397-404. PubMed ID: 22057246 [TBL] [Abstract][Full Text] [Related]
5. Comparison of pressure- and flow-triggered pressure-support ventilation on weaning parameters in patients recovering from acute respiratory failure. Tütüncü AS; Cakar N; Camci E; Esen F; Telci L; Akpir K Crit Care Med; 1997 May; 25(5):756-60. PubMed ID: 9187592 [TBL] [Abstract][Full Text] [Related]
6. Monitoring of functional residual capacity by an oxygen washin/washout; technical description and evaluation. Weismann D; Reissmann H; Maisch S; Füllekrug B; Schulte J J Clin Monit Comput; 2006 Aug; 20(4):251-60. PubMed ID: 16832581 [TBL] [Abstract][Full Text] [Related]
7. Measurement of functional residual capacity of the lung by partial CO2 rebreathing method during acute lung injury in animals. Brewer LM; Haryadi DG; Orr JA Respir Care; 2007 Nov; 52(11):1480-9. PubMed ID: 17971251 [TBL] [Abstract][Full Text] [Related]
8. A system to measure functional residual capacity in critically ill patients. Paloski WH; Newell JC; Gisser DG; Stratton HH; Annest SJ; Gottlieb ME; Shah DM Crit Care Med; 1981 Apr; 9(4):342-6. PubMed ID: 7011678 [TBL] [Abstract][Full Text] [Related]
9. Validation and clinical feasibility of nitrogen washin/washout functional residual capacity measurements in children. Olegård C; Søndergaard S; Pålsson J; Lundin S; Stenqvist O Acta Anaesthesiol Scand; 2010 Mar; 54(3):370-6. PubMed ID: 19839952 [TBL] [Abstract][Full Text] [Related]
10. Measurement of functional residual capacity by helium dilution during partial support ventilation: in vitro accuracy and in vivo precision of the method. Di Marco F; Rota Sperti L; Milan B; Stucchi R; Centanni S; Brochard L; Fumagalli R Intensive Care Med; 2007 Dec; 33(12):2109-15. PubMed ID: 17703280 [TBL] [Abstract][Full Text] [Related]
11. Modification of the open circuit N2 washout technique for measurement of functional residual capacity in premature infants. Hentschel R; Suska A; Volbracht A; Brune T; Jorch G Pediatr Pulmonol; 1997 Jun; 23(6):434-41. PubMed ID: 9220526 [TBL] [Abstract][Full Text] [Related]
12. Estimation of functional residual capacity at the bedside using standard monitoring equipment: a modified nitrogen washout/washin technique requiring a small change of the inspired oxygen fraction. Olegård C; Söndergaard S; Houltz E; Lundin S; Stenqvist O Anesth Analg; 2005 Jul; 101(1):206-12, table of contents. PubMed ID: 15976233 [TBL] [Abstract][Full Text] [Related]
13. Measurement of lung volume in mechanically ventilated monkeys with an ultrasonic flow meter and the nitrogen washout method. Schibler A; Hammer J; Isler R; Buess C; Newth CJ Intensive Care Med; 2004 Jan; 30(1):127-32. PubMed ID: 14530860 [TBL] [Abstract][Full Text] [Related]
14. An experimental randomized study of five different ventilatory modes in a piglet model of severe respiratory distress. Lichtwarck-Aschoff M; Nielsen JB; Sjöstrand UH; Edgren EL Intensive Care Med; 1992; 18(6):339-47. PubMed ID: 1469161 [TBL] [Abstract][Full Text] [Related]
15. Predictive value of FRC and respiratory compliance on pulmonary gas exchange induced by high frequency jet ventilation in humans. Pittet JF; Morel DR; Bachmann M; Forster A; Suter PM Br J Anaesth; 1990 Apr; 64(4):460-8. PubMed ID: 2185815 [TBL] [Abstract][Full Text] [Related]
16. Validation and clinical application of a first order step response equation for nitrogen clearance during FRC measurement. Choncholas G; Sondergaard S; Heinonen E J Clin Monit Comput; 2008 Feb; 22(1):1-9. PubMed ID: 18004668 [TBL] [Abstract][Full Text] [Related]
17. Validation of a nitrogen washout system to measure functional residual capacity in premature infants with hyaline membrane disease. Miller J; Law AB; Parker RA; Sundell HW; Lindstrom DP; Cotton RB Pediatr Pulmonol; 1995 Dec; 20(6):403-9. PubMed ID: 8649921 [TBL] [Abstract][Full Text] [Related]
18. A simple method to estimate functional residual capacity in mechanically ventilated patients. Fretschner R; Deusch H; Weitnauer A; Brunner JX Intensive Care Med; 1993; 19(7):372-6. PubMed ID: 8270715 [TBL] [Abstract][Full Text] [Related]
19. Determination of functional residual capacity by oxygen washin-washout: a validation study. Maisch S; Boehm SH; Weismann D; Reissmann H; Beckmann M; Fuellekrug B; Meyer A; Schulte Am Esch J Intensive Care Med; 2007 May; 33(5):912-916. PubMed ID: 17361389 [TBL] [Abstract][Full Text] [Related]
20. An evaluation of the multiple-breath nitrogen washout as a pulmonary function test in dairy cattle. Gallivan GJ; McDonell WN Can J Vet Res; 1989 Apr; 53(2):133-42. PubMed ID: 2713778 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]