BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

275 related articles for article (PubMed ID: 12596613)

  • 1. The tracheal detecting-bulb: a new device to distinguish tracheal from esophageal intubation.
    Tong YL; Sun M; Tang WH; Xia JY
    Acta Anaesthesiol Sin; 2002 Dec; 40(4):159-63. PubMed ID: 12596613
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The esophageal detector device. Does it work?
    Zaleski L; Abello D; Gold MI
    Anesthesiology; 1993 Aug; 79(2):244-7. PubMed ID: 8342836
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Aspirated air capnography with esophageal detector device to confirm tracheal intubation in rapid sequence induction.
    Ghabash M; Choueiry P; Matta M
    Middle East J Anaesthesiol; 1998 Jun; 14(5):381-6. PubMed ID: 9785341
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [A clinical study of impedance graph in verifying tracheal intubation].
    Yao YX; Jiang Z; Lu XH; He JH; Ma XX; Zhu JH
    Zhonghua Yi Xue Za Zhi; 2007 Apr; 87(13):898-901. PubMed ID: 17650400
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation.
    Li J
    J Emerg Med; 2001 Apr; 20(3):223-9. PubMed ID: 11267809
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Efficacy of the self-inflating bulb in detecting esophageal intubation. Does the presence of a nasogastric tube or cuff deflation make a difference?
    Salem MR; Wafai Y; Joseph NJ; Baraka A; Czinn EA
    Anesthesiology; 1994 Jan; 80(1):42-8. PubMed ID: 8291728
    [TBL] [Abstract][Full Text] [Related]  

  • 7. [Blocking the spray of contaminants from patients' exhalent using a tracheal detecting bulb during endotracheal intubation].
    Tong YL; Sun M; Wang Z; Li B; Xie J; Ye H
    Zhongguo Wei Zhong Bing Ji Jiu Yi Xue; 2011 Nov; 23(11):650-2. PubMed ID: 22093308
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Comparison of three different methods to confirm tracheal tube placement in emergency intubation.
    Grmec S
    Intensive Care Med; 2002 Jun; 28(6):701-4. PubMed ID: 12107674
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Airway management in children: ultrasonography assessment of tracheal intubation in real time?
    Marciniak B; Fayoux P; Hébrard A; Krivosic-Horber R; Engelhardt T; Bissonnette B
    Anesth Analg; 2009 Feb; 108(2):461-5. PubMed ID: 19151273
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation study of two-microphone acoustic reflectometry for determination of breathing tube placement in 200 adult patients.
    Raphael DT; Benbassat M; Arnaudov D; Bohorquez A; Nasseri B
    Anesthesiology; 2002 Dec; 97(6):1371-7. PubMed ID: 12459661
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Use of the self-inflating bulb for detecting esophageal intubation after "esophageal ventilation".
    Salem MR; Wafai Y; Baraka A; Taimorrazy B; Joseph NJ; Nimmagadda U
    Anesth Analg; 1993 Dec; 77(6):1227-31. PubMed ID: 8250317
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The esophageal detector bulb in the aeromedical setting.
    Hendey GW; Shubert GS; Shalit M; Hogue B
    J Emerg Med; 2002 Jul; 23(1):51-5. PubMed ID: 12217472
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A novel method to detect accidental oesophageal intubation based on ventilation pressure waveforms.
    Kalmar AF; Absalom A; Monsieurs KG
    Resuscitation; 2012 Feb; 83(2):177-82. PubMed ID: 22044726
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Endotracheal tube placement confirmation: 100% sensitivity and specificity with sustained four-phase capnographic waveforms in a cadaveric experimental model.
    Silvestri S; Ladde JG; Brown JF; Roa JV; Hunter C; Ralls GA; Papa L
    Resuscitation; 2017 Jun; 115():192-198. PubMed ID: 28111195
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A comparative study of methods of detection of esophageal intubation.
    Sum-Ping ST; Mehta MP; Anderton JM
    Anesth Analg; 1989 Nov; 69(5):627-32. PubMed ID: 2508509
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The oesophageal detector device. Assessment of a new method to distinguish oesophageal from tracheal intubation.
    Wee MY
    Anaesthesia; 1988 Jan; 43(1):27-9. PubMed ID: 3344944
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The use of capnography for recognition of esophageal intubation in the neonatal intensive care unit.
    Roberts WA; Maniscalco WM; Cohen AR; Litman RS; Chhibber A
    Pediatr Pulmonol; 1995 May; 19(5):262-8. PubMed ID: 7567200
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Detection of tracheal malpositioning of nasogastric tubes using endotracheal cuff pressure measurement.
    Fuchs J; Schummer C; Giesser J; Bayer O; Schummer W
    Acta Anaesthesiol Scand; 2007 Oct; 51(9):1245-9. PubMed ID: 17850566
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prehospital determination of tracheal tube placement in severe head injury.
    Grmec S; Mally S
    Emerg Med J; 2004 Jul; 21(4):518-20. PubMed ID: 15208251
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of the SCOTI device for confirming blind nasal intubation.
    Trikha A; Singh C; Rewari V; Arora MK
    Anaesthesia; 1999 Apr; 54(4):347-9. PubMed ID: 10455832
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 14.