These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

118 related articles for article (PubMed ID: 12596991)

  • 1. Evaluation of systematic errors in thyroid monitoring.
    Venturini L
    Radiat Prot Dosimetry; 2003; 103(1):63-8. PubMed ID: 12596991
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte-Carlo simulation of uncertainty in the estimation of 125I in the thyroid.
    Bhati S; Patni HK
    Radiat Prot Dosimetry; 2009 Aug; 136(1):23-9. PubMed ID: 19689965
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Performance assessment and uncertainty evaluation of a portable NaI-based detection system used for thyroid monitoring.
    Bento J; Martins B; Teles P; Neves M; Colarinha P; Alves F; Teixeira N; Vaz P; Zankl M
    Radiat Prot Dosimetry; 2012 Aug; 151(2):252-61. PubMed ID: 22345216
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Estimation of counting efficiencies of a portable NaI detector using Monte Carlo simulation for thyroid measurement following nuclear accidents.
    Ha WH; Kim JK; Jin YW
    J Radiol Prot; 2017 Sep; 37(3):635-641. PubMed ID: 28474600
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Counting efficiency of whole-body monitoring system using BOMAB and ANSI/IAEA thyroid phantom due to internal contamination of 131I.
    Ghare VP; Patni HK; Akar DK; Rao DD
    Radiat Prot Dosimetry; 2014 Dec; 162(3):230-5. PubMed ID: 24179144
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The assessment of the effect of thyroid size and shape on the activity estimate using Monte Carlo simulation.
    Kramer GH; Crowley P
    Health Phys; 2000 Jun; 78(6):727-38. PubMed ID: 10832935
    [TBL] [Abstract][Full Text] [Related]  

  • 7. MCNP SIMULATIONS WITH A PERSONALISED VOXEL PHANTOM TO VERIFY 131I CONTENT IN THYROID ESTIMATED BASED ON MEASUREMENTS WITH AN NaI(Tl) SPECTROMETER.
    Tani K; Kunishima N; Igarashi Y; Kim E; Iimoto T; Kurihara O
    Radiat Prot Dosimetry; 2019 Dec; 185(3):402-408. PubMed ID: 30806469
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Examination of the effect of counting geometry on 125I monitoring using MCNP.
    Kramer GH; Yiu S
    Health Phys; 1997 Mar; 72(3):465-70. PubMed ID: 9030849
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Monte Carlo calculation of response functions to gamma-ray point sources for a spherical NaI(Tl) detector.
    Yi CY; Hah SH
    Appl Radiat Isot; 2012 Sep; 70(9):2133-6. PubMed ID: 22424837
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Counting Efficiencies Determined by Monte Carlo Methods for In Vivo Measurement of 131I Activity in Thyroid.
    Park M; Kwon TE; Ha WH; Kim CH; Park S; Jin YW
    Health Phys; 2019 Oct; 117(4):388-395. PubMed ID: 30913058
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monte Carlo simulation of NaI(TL) detector in a shadow-shield scanning bed whole-body monitor for uniform and axial cavity activity distribution in a BOMAB phantom.
    Akar DK; Patni HK; Nadar MY; Ghare VP; Rao DD
    Radiat Prot Dosimetry; 2013 Jul; 155(3):292-9. PubMed ID: 23390143
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A study of thyroid radioiodine monitoring by Monte Carlo simulations: implications for equipment design.
    Kramer GH; Chamberlain MJ; Yiu S
    Phys Med Biol; 1997 Nov; 42(11):2175-82. PubMed ID: 9394405
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Absorbed fractions for photons of 125I and 129I in the thyroid.
    Widman JC; Powsner ER; Plato PA
    Int J Appl Radiat Isot; 1980 Jul; 31(7):421-3. PubMed ID: 7429657
    [No Abstract]   [Full Text] [Related]  

  • 14. Longitudinal monitoring of whole body counter NaI(Tl) detector efficiency.
    Shypailo RJ
    Appl Radiat Isot; 2017 Jul; 125():74-79. PubMed ID: 28411537
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparison of the ANSI, RSD, KKH, and BRMD thyroid-neck phantoms for 125I thyroid monitoring.
    Kramer GH; Olender G; Vlahovich S; Hauck BM; Meyerhof DP
    Health Phys; 1996 Mar; 70(3):425-9. PubMed ID: 8609037
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Application of the Monte Carlo method for the efficiency calibration of CsI and NaI detectors for gamma-ray measurements from terrestrial samples.
    Baccouche S; Al-Azmi D; Karunakara N; Trabelsi A
    Appl Radiat Isot; 2012 Jan; 70(1):227-32. PubMed ID: 21852143
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Determination of uncertainties associated to the in vivo measurement of iodine-131 in the thyroid.
    Dantas BM; Lima FF; Dantas AL; Lucena EA; Gontijo RM; Carvalho CB; Hazin C
    Appl Radiat Isot; 2016 Jul; 113():1-4. PubMed ID: 27108067
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Temporal Fluctuations in Indoor Background Gamma Radiation Using NaI(Tl).
    Smith T; Cao S; Kearfott KJ
    Health Phys; 2018 Mar; 114(3):360-372. PubMed ID: 29360714
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Age-specific calibration for in vivo monitoring of thyroid: is it necessary?
    Sohrabi R; Miri-Hakimabad H; Hoseinian-Azghadi E; Vega-Carrillo HR
    Radiat Environ Biophys; 2022 Aug; 61(3):399-406. PubMed ID: 35842886
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Monte Carlo Simulation Used to Calculate Energy Correction Factor for Thermoluminescent Dosimeters Used by Occupational Workers on Pediatric Exams.
    Hoff G; Filipov D; Paschuk S; Schelin HR; Denyak V
    Radiat Prot Dosimetry; 2017 Dec; 177(3):223-242. PubMed ID: 28419323
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.