133 related articles for article (PubMed ID: 12600967)
21. Reference ranges for serum total and monomeric prolactin for the current generation Abbott Architect assay.
Whitehead SJ; Cornes MP; Ford C; Gama R
Ann Clin Biochem; 2015 Jan; 52(Pt 1):61-6. PubMed ID: 25074991
[TBL] [Abstract][Full Text] [Related]
22. Macroprolactinaemia: contribution to hyperprolactinaemia in a district general hospital and evaluation of a screening test based on precipitation with polyethylene glycol.
Fahie-Wilson MN; Soule SG
Ann Clin Biochem; 1997 May; 34 ( Pt 3)():252-8. PubMed ID: 9158821
[TBL] [Abstract][Full Text] [Related]
23. The Beckman DxI 800 prolactin assay demonstrates superior specificity for monomeric prolactin.
Byrne B; O'Shea P; Barrett P; Tormey W
Clin Chem Lab Med; 2010 Feb; 48(2):205-8. PubMed ID: 19943807
[TBL] [Abstract][Full Text] [Related]
24. Is polyethylene glycol precipitation of hyperprolactinaemic samples required when using the Beckman Coulter DxI-800 prolactin assay?
Hawkins RC
Clin Chem Lab Med; 2012 Feb; 50(4):757-9. PubMed ID: 22505565
[No Abstract] [Full Text] [Related]
25. The detection of macroprolactin by precipitation and ultrafiltration methods.
Beda-Maluga K; Pisarek H; Komorowski J; Pawlikowski M; Świętosławski J; Winczyk K
Endokrynol Pol; 2011; 62(6):529-36. PubMed ID: 22144220
[TBL] [Abstract][Full Text] [Related]
26. Importance of screening for macroprolactin in all hyperprolactinaemic sera.
Jamaluddin FA; Sthaneshwar P; Hussein Z; Othman N; Chan SP
Malays J Pathol; 2013 Jun; 35(1):59-63. PubMed ID: 23817395
[TBL] [Abstract][Full Text] [Related]
27. Polyethylene glycol precipitation as a screening method for macroprolactinemia.
Fahie-Wilson MN
Clin Chem; 1999 Mar; 45(3):436-7. PubMed ID: 10053056
[No Abstract] [Full Text] [Related]
28. Gross variability in the detection of prolactin in sera containing big big prolactin (macroprolactin) by commercial immunoassays.
Smith TP; Suliman AM; Fahie-Wilson MN; McKenna TJ
J Clin Endocrinol Metab; 2002 Dec; 87(12):5410-5. PubMed ID: 12466327
[TBL] [Abstract][Full Text] [Related]
29. Screening for macroprolactinaemia.
Olukoga AO; Kane J
Ann Clin Biochem; 1997 Nov; 34 ( Pt 6)():701-3; author reply 703-4. PubMed ID: 9367016
[No Abstract] [Full Text] [Related]
30. Extensive experience and validation of polyethylene glycol precipitation as a screening method for macroprolactinemia.
Vieira JG; Tachibana TT; Obara LH; Maciel RM
Clin Chem; 1998 Aug; 44(8 Pt 1):1758-9. PubMed ID: 9702971
[No Abstract] [Full Text] [Related]
31. Rapid detection of macroprolactin in the form of prolactin-immunoglobulin G complexes by immunoprecipitation with anti-human IgG-agarose.
Schiettecatte J; De Schepper J; Velkeniers B; Smitz J; Van Steirteghem A
Clin Chem Lab Med; 2001 Dec; 39(12):1244-8. PubMed ID: 11798085
[TBL] [Abstract][Full Text] [Related]
32. Free prolactin determinations in hyperprolactinemic men with suspicion of macroprolactinemia.
Sapin R; Gasser F; Grucker D
Clin Chim Acta; 2002 Feb; 316(1-2):33-41. PubMed ID: 11750272
[TBL] [Abstract][Full Text] [Related]
33. Serum total prolactin and monomeric prolactin reference intervals determined by precipitation with polyethylene glycol: evaluation and validation on common immunoassay platforms.
Beltran L; Fahie-Wilson MN; McKenna TJ; Kavanagh L; Smith TP
Clin Chem; 2008 Oct; 54(10):1673-81. PubMed ID: 18719199
[TBL] [Abstract][Full Text] [Related]
34. Hyperprolactinaemia does not always mean 'hyperprolactinaemia'!
Gezer A; Atasü T; Hekim C; Stenman UH; Hekim N
Eur J Obstet Gynecol Reprod Biol; 2005 Feb; 118(2):206-8. PubMed ID: 15653204
[TBL] [Abstract][Full Text] [Related]
35. Evaluation of hyperprolactinaemia with the use of the intervals for prolactin after macroforms separation.
Beda-Maluga K; Pisarek H; Komorowski J; Swietoslawski J; Fuss-Chmielewska J; Winczyk K
J Physiol Pharmacol; 2014 Jun; 65(3):359-64. PubMed ID: 24930507
[TBL] [Abstract][Full Text] [Related]
36. [Prolactin and the laboratory].
Veloza A; Prazeres S
Acta Med Port; 2011 Dec; 24 Suppl 4():1029-34. PubMed ID: 22863514
[TBL] [Abstract][Full Text] [Related]
37. Detection of macroprolactin causing hyperprolactinemia in commercial assays for prolactin.
Fahie-Wilson MN
Clin Chem; 2000 Dec; 46(12):2022-3. PubMed ID: 11106347
[No Abstract] [Full Text] [Related]
38. Optimization of a Screening Method for Macroprolactinemia.
Yang W; Guo Z; Zhou Y; Du J; Liu H; Jia J; Shen Y; Chen Y
J Chromatogr B Analyt Technol Biomed Life Sci; 2021 Jun; 1175():122723. PubMed ID: 33989987
[TBL] [Abstract][Full Text] [Related]
39. Evaluation of monomeric prolactin level by TRACE method and precipitation with polyethylene glycol.
Vorotnikova SY; Dzeranova LK; Fedorova NS; Pigarova EA; Vershinina MG; Il'in AV
Klin Lab Diagn; 2021 Mar; 66(2):69-74. PubMed ID: 33734638
[TBL] [Abstract][Full Text] [Related]
40. Macroprolactinaemia: validation and application of the polyethylene glycol precipitation test and clinical characterization of the condition.
Olukoga AO; Kane JW
Clin Endocrinol (Oxf); 1999 Jul; 51(1):119-26. PubMed ID: 10468974
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]