BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

415 related articles for article (PubMed ID: 12604931)

  • 1. Demise of the mercury sphygmomanometer and the dawning of a new era in blood pressure measurement.
    O'Brien E
    Blood Press Monit; 2003 Feb; 8(1):19-21. PubMed ID: 12604931
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of sphygmomanometers at pharmacies.
    Erdem DG; Erdem E; Dilek M; Aydogdu T; Selim N; Demiray F; Sari A; Akpolat T
    Kidney Blood Press Res; 2009; 32(4):231-4. PubMed ID: 19622898
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Validation of the Samsung SBM-100A and Microlife BP 3BU1-5 wrist blood pressure measuring devices in adults according to the International Protocol.
    Altunkan S; Ilman N; Altunkan E
    Blood Press Monit; 2007 Apr; 12(2):119-25. PubMed ID: 17353656
    [TBL] [Abstract][Full Text] [Related]  

  • 4. A new audiovisual technique for recording blood pressure in research: the Sphygmocorder.
    O'Brien E; Atkins N; Mee F; Coyle D; Syed S
    J Hypertens; 1995 Dec; 13(12 Pt 2):1734-7. PubMed ID: 8903642
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validation of two automatic devices for self-measurement of blood pressure according to the International Protocol of the European Society of Hypertension: the Omron M6 (HEM-7001-E) and the Omron R7 (HEM 637-IT).
    Topouchian JA; El Assaad MA; Orobinskaia LV; El Feghali RN; Asmar RG
    Blood Press Monit; 2006 Jun; 11(3):165-71. PubMed ID: 16702826
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automated blood pressure measurement: state of the market in 1998 and the need for an international validation protocol for blood pressure measuring devices.
    O'Brien E
    Blood Press Monit; 1998 Jun; 3(3):205-211. PubMed ID: 10212355
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Validation of three oscillometric blood pressure devices against auscultatory mercury sphygmomanometer in children.
    Wong SN; Tz Sung RY; Leung LC
    Blood Press Monit; 2006 Oct; 11(5):281-91. PubMed ID: 16932037
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Validation of the Omron M5-I, R5-I and HEM-907 automated blood pressure monitors in elderly individuals according to the International Protocol of the European Society of Hypertension.
    Omboni S; Riva I; Giglio A; Caldara G; Groppelli A; Parati G
    Blood Press Monit; 2007 Aug; 12(4):233-42. PubMed ID: 17625396
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Validation of TM-2655 oscillometric device for blood pressure measurement.
    Kobalava ZD; Kotovskaya YV; Babaeva LA; Moiseev VS
    Blood Press Monit; 2006 Apr; 11(2):87-90. PubMed ID: 16534410
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of the Omron M6 (HEM-7001-E) upper-arm blood pressure measuring device according to the International Protocol in adults and obese adults.
    Altunkan S; Ilman N; Kayatürk N; Altunkan E
    Blood Press Monit; 2007 Aug; 12(4):219-25. PubMed ID: 17625394
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Alternatives to the mercury sphygmomanometer.
    Buchanan S; Orris P; Karliner J
    J Public Health Policy; 2011 Feb; 32(1):107-20. PubMed ID: 21109765
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A comparison of two sphygmomanometers that may replace the traditional mercury column in the healthcare workplace.
    Elliott WJ; Young PE; DeVivo L; Feldstein J; Black HR
    Blood Press Monit; 2007 Feb; 12(1):23-8. PubMed ID: 17303984
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Arterial blood pressure measurement with mercury sphygmomanometer--more than a technique].
    Jelaković B; Laganović M
    Lijec Vjesn; 2006; 128(11-12):398-401. PubMed ID: 17212207
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Measuring blood pressure using the mercury sphygmomanometer.
    Valler-Jones T; Wedgbury K
    Br J Nurs; 2005 Feb 10-23; 14(3):145-50. PubMed ID: 15788933
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A new technique for simultaneous validation of two manual nonmercury auscultatory sphygmomanometers (A&D UM-101 and Accoson Greenlight 300) based on the International protocol.
    Pruijm MT; Wuerzner G; Glatz N; Alwan H; Ponte B; Ackermann D; Burnier M; Bochud M
    Blood Press Monit; 2010 Dec; 15(6):322-5. PubMed ID: 20827175
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Arterial pressure waveforms in hypertension.
    O'Rourke MF
    Minerva Med; 2003 Aug; 94(4):229-50. PubMed ID: 14605588
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Validation of the OMRON M7 (HEM-780-E) blood pressure measuring device in a population requiring large cuff use according to the International Protocol of the European Society of Hypertension.
    El Feghali RN; Topouchian JA; Pannier BM; El Assaad HA; Asmar RG;
    Blood Press Monit; 2007 Jun; 12(3):173-8. PubMed ID: 17496467
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Validation of the HEM-780REL with easy wrap cuff for self-measurement of blood pressure according to the European Society of Hypertension International Protocol.
    Viera AJ; Hinderliter AL
    Blood Press Monit; 2007 Oct; 12(5):335-8. PubMed ID: 17890973
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Has conventional sphygmomanometry ended with the banning of mercury?
    O'Brien E
    Blood Press Monit; 2002 Feb; 7(1):37-40. PubMed ID: 12040241
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Validation of the Artsana CS 410 automated blood pressure monitor in adults according to the International Protocol of the European Society of Hypertension.
    Pini C; Natalizi A; Gerosa PF; Frigerio M; Omboni S; Parati G
    Blood Press Monit; 2008 Jun; 13(3):177-82. PubMed ID: 18496297
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 21.