These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 12607959)

  • 1. [The influence of medial implant location in three-unit posterior cantilever fixed partial dentures on stress distribution in surrounding mandibular bone].
    Yokoyama S; Wakabayashi N; Shiota M; Ohyama T
    Kokubyo Gakkai Zasshi; 2002 Dec; 69(4):263-8. PubMed ID: 12607959
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Three-dimensional finite element analysis of the effect of the location and diameter of implants on the stress distribution in three-unit implant-supported posterior cantilever fixed partial dentures under dynamic loads].
    Lü J; Liu C; Lan J; Gao X
    Hua Xi Kou Qiang Yi Xue Za Zhi; 2013 Dec; 31(6):552-6. PubMed ID: 24437284
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The influence of implant location and length on stress distribution for three-unit implant-supported posterior cantilever fixed partial dentures.
    Yokoyama S; Wakabayashi N; Shiota M; Ohyama T
    J Prosthet Dent; 2004 Mar; 91(3):234-40. PubMed ID: 15060492
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Three-dimensional finite element analysis of cantilever fixed bridge supported by implants with mandibular central incisor].
    He YT; Ma CL; Qiao G; Liu JY; Wang Y; Song J; Liu Y; Wang ZH
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2019 Jul; 54(7):463-468. PubMed ID: 31288326
    [No Abstract]   [Full Text] [Related]  

  • 5. [Analysis of the effect of mesial implant position on surrounding bone stress of mandibular edentulous jaw under dynamic loads].
    Li Y; Sun C; Jia H; Luo XJ
    Zhonghua Kou Qiang Yi Xue Za Zhi; 2017 Nov; 52(11):672-677. PubMed ID: 29972946
    [No Abstract]   [Full Text] [Related]  

  • 6. The influence of occlusal loading location on stresses transferred to implant-supported prostheses and supporting bone: A three-dimensional finite element study.
    Eskitascioglu G; Usumez A; Sevimay M; Soykan E; Unsal E
    J Prosthet Dent; 2004 Feb; 91(2):144-50. PubMed ID: 14970760
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Role of implant configurations supporting three-unit fixed partial denture on mandibular bone response: biological-data-based finite element study.
    Yoda N; Liao Z; Chen J; Sasaki K; Swain M; Li Q
    J Oral Rehabil; 2016 Sep; 43(9):692-701. PubMed ID: 27224022
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The effect of implant design on the stress distribution in a three-unit implant-supported distal cantilever fixed partial denture: a three-dimensional finite-element analysis.
    Koka P; Mohapatra A; Anandapandian PA; Murugesan K; Vasanthakumar M
    Indian J Dent Res; 2012; 23(2):129-34. PubMed ID: 22945697
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Stress Analysis for Different Designs of Implant-borne and Tooth-implant Fixed Partial Dentures in Mandibular Posterior Region.
    Hamed MT; Mously HA
    J Contemp Dent Pract; 2019 Dec; 20(12):1375-1379. PubMed ID: 32381835
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical evaluation of tooth- and implant-supported fixed dental prostheses with various nonrigid connector positions: a finite element analysis.
    Burak Özcelik T; Ersoy E; Yilmaz B
    J Prosthodont; 2011 Jan; 20(1):16-28. PubMed ID: 21251117
    [TBL] [Abstract][Full Text] [Related]  

  • 11. An In Vivo Study on Load Distribution in Different Implant Configurations for Supporting Fixed Partial Dentures.
    Kobari H; Yoda N; Chen J; Kawata T; Sasaki K
    Int J Oral Maxillofac Implants; 2016; 31(5):1049-57. PubMed ID: 27632259
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Influence of implant framework and mandibular flexure on the strain distribution on a Kennedy class II mandible restored with a long-span implant fixed restoration: a pilot study.
    Law C; Bennani V; Lyons K; Swain M
    J Prosthet Dent; 2014 Jul; 112(1):31-7. PubMed ID: 24388719
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Is Anterior Guidance a Key Factor on Planning Implant Treatment for Free-End Missing in the Posterior Mandible?
    Nagao M; Masaki C; Nakao M; Ito Y; Tsuka S; Mukaibo T; Kondo Y; Hosokawa R
    J Oral Implantol; 2019 Apr; 45(2):100-105. PubMed ID: 30540538
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Comparative evaluation of the effect of diameter, length and number of implants supporting three-unit fixed partial prostheses on stress distribution in the bone.
    Iplikçioğlu H; Akça K
    J Dent; 2002 Jan; 30(1):41-6. PubMed ID: 11741734
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Comparative Finite Element Analysis of Short Implants with Different Treatment Approaches in the Atrophic Mandible.
    Doganay O; Kilic E
    Int J Oral Maxillofac Implants; 2020; 35(4):e69-e76. PubMed ID: 32724926
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Three-dimensional finite element analysis of the influence of implant location on the stress distribution for implant-supported fixed partial dentures].
    Huang QF; Zhang FQ; Hu Y; Wang DM
    Shanghai Kou Qiang Yi Xue; 2008 Aug; 17(4):400-4. PubMed ID: 18784882
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Biomechanical effects of two different collar implant structures on stress distribution under cantilever fixed partial dentures.
    Merıç G; Erkmen E; Kurt A; Eser A; özden AU
    Acta Odontol Scand; 2011 Nov; 69(6):374-84. PubMed ID: 21449688
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Biomechanical comparison of axial and tilted implants for mandibular full-arch fixed prostheses.
    Kim KS; Kim YL; Bae JM; Cho HW
    Int J Oral Maxillofac Implants; 2011; 26(5):976-84. PubMed ID: 22010079
    [TBL] [Abstract][Full Text] [Related]  

  • 19. On occlusal forces in dentitions with implant-supported fixed cantilever prostheses.
    Falk H
    Swed Dent J Suppl; 1990; 69():1-40. PubMed ID: 2196708
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Evaluation of Effect of Connector Designs in Implant Tooth-supported Fixed Partial Denture: A Two-dimensional Finite Element Analysis.
    Gowda S; Quadras DD; Sesappa RS; Katapadi V; Kumar L; Kulkarni D; Mishra N
    J Contemp Dent Pract; 2018 Jun; 19(6):669-674. PubMed ID: 29959294
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.