These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Measurements of intraocular pressure by Goldmann tonometry, Tonopen XL, and the transpalpebral tonometer, TGDc-01, after penetrating keratoplasty: a comparativye study. Shemesh G; Waisbourd M; Varssano D; Michaeli A; Lazar M; Kurtz S Cornea; 2009 Aug; 28(7):724-7. PubMed ID: 19574919 [TBL] [Abstract][Full Text] [Related]
3. The validity of a digital eyelid tonometer (TGDc-01) and its comparison with Goldmann applanation tonometry - a pilot study. Lam AK; Lam CH; Chan R Ophthalmic Physiol Opt; 2005 May; 25(3):205-10. PubMed ID: 15854065 [TBL] [Abstract][Full Text] [Related]
4. [Intraocular pressure difference in Goldmann applanation tonometry versus a transpalpebral tonometer TGDc-01"PRA" in glaucoma patients]. Schlote T; Landenberger H Klin Monbl Augenheilkd; 2005 Feb; 222(2):123-31. PubMed ID: 15719316 [TBL] [Abstract][Full Text] [Related]
5. Evaluation of the pressure phosphene tonometer as a self-tonometer. Naruse S; Mori K; Kinoshita S Ophthalmic Physiol Opt; 2005 Sep; 25(5):421-8. PubMed ID: 16101948 [TBL] [Abstract][Full Text] [Related]
6. Three portable tonometers, the TGDc-01, the ICARE and the Tonopen XL, compared with each other and with Goldmann applanation tonometry*. van der Jagt LH; Jansonius NM Ophthalmic Physiol Opt; 2005 Sep; 25(5):429-35. PubMed ID: 16101949 [TBL] [Abstract][Full Text] [Related]
7. Assessment of true intraocular pressure: the gap between theory and practical data. Chihara E Surv Ophthalmol; 2008; 53(3):203-18. PubMed ID: 18501267 [TBL] [Abstract][Full Text] [Related]
9. Noninvasive measurement of rodent intraocular pressure with a rebound tonometer. Wang WH; Millar JC; Pang IH; Wax MB; Clark AF Invest Ophthalmol Vis Sci; 2005 Dec; 46(12):4617-21. PubMed ID: 16303957 [TBL] [Abstract][Full Text] [Related]
10. [Intraocular pressure measurements with the Proview self-tonometer in comparison of Goldmann applanation tonometry in healthy and glaucomatous eyes]. Meyer MW; Yevelenko V; Hoy L; Meyer A; Erb C Klin Monbl Augenheilkd; 2006 Nov; 223(11):899-903. PubMed ID: 17131250 [TBL] [Abstract][Full Text] [Related]
11. The Proview phosphene tonometer fails to measure ocular pressure accurately in clinical practice. Alvarez TL; Gollance SA; Thomas GA; Greene RJ; Marchetto PM; Moore EJ; Realini T; Liebmann JM; Ritch R; Lama P; Fechtner RD Ophthalmology; 2004 Jun; 111(6):1077-85. PubMed ID: 15177956 [TBL] [Abstract][Full Text] [Related]
15. Comparison of the ICare rebound tonometer with the Goldmann tonometer in a normal population. Fernandes P; Díaz-Rey JA; Queirós A; Gonzalez-Meijome JM; Jorge J Ophthalmic Physiol Opt; 2005 Sep; 25(5):436-40. PubMed ID: 16101950 [TBL] [Abstract][Full Text] [Related]
16. [Indicator tonometer for measuring intraocular pressure on the operating table]. Vurgaft IaM Oftalmol Zh; 1979; 34(6):373-4. PubMed ID: 537730 [No Abstract] [Full Text] [Related]
17. [Results of clinical trials of the OTM-01A ophthalmic tonometer]. Buromskaia LM Med Tekh; 1991; (3):31-3. PubMed ID: 1895900 [TBL] [Abstract][Full Text] [Related]
18. Disposable devices for measuring intraocular pressure: a clinical study to assess their accuracy. Bhatnagar A; Gupta AK Eye (Lond); 2005 Jul; 19(7):752-4. PubMed ID: 15359247 [TBL] [Abstract][Full Text] [Related]
19. The Proview Eye Pressure Monitor: influence of clinical factors on accuracy and agreement with the Goldmann tonometer. Herse P; Hans A; Hall J; Langejans J; Markoulli M Ophthalmic Physiol Opt; 2005 Sep; 25(5):416-20. PubMed ID: 16101947 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of the Perkins handheld applanation tonometer in the measurement of intraocular pressure in dogs and cats. Andrade SF; Cremonezi T; Zachi CA; Lonchiati CF; Amatuzzi JD; Sakamoto KP; Mello PA Vet Ophthalmol; 2009; 12(5):277-84. PubMed ID: 19751486 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]