These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

202 related articles for article (PubMed ID: 1261311)

  • 21. Longitudinal validity of spirometers--a challenge in longitudinal studies.
    Künzli N; Kuna-Dibbert B; Keidel D; Keller R; Brändli O; Schindler C; Schweinzer KM; Leuenberger P; Ackermann-Liebrich U;
    Swiss Med Wkly; 2005 Aug; 135(33-34):503-8. PubMed ID: 16208589
    [TBL] [Abstract][Full Text] [Related]  

  • 22. A comparison of a new transtelephonic portable spirometer with a laboratory spirometer.
    Izbicki G; Abboud S; Jordan P; Perruchoud AP; Bolliger CT
    Eur Respir J; 1999 Jul; 14(1):209-13. PubMed ID: 10489853
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Clinical evaluation of five spirometers. Monaghan M403, Pneumoscreen, Spirotron, Vicatest and Vitalograph.
    Wever AM; Britton MG; Hughes DT; Van der Plas KH; Wever-Hess J
    Eur J Respir Dis; 1981; 62(2):127-37. PubMed ID: 7238663
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Evaluating commercially available spirometers.
    Gardner RM; Hankinson JL; West BJ
    Am Rev Respir Dis; 1980 Jan; 121(1):73-82. PubMed ID: 7352715
    [TBL] [Abstract][Full Text] [Related]  

  • 25. [Evaluation of the reliability of 2 portable electronic spirometers].
    Tschopp JM; Roulin JP; Juilland A; Erné R
    Schweiz Med Wochenschr; 1988 Sep; 118(38):1382-5. PubMed ID: 3187474
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Comparison of a portable, pneumotach flow-sensor-based spirometer (Spirofy™) with the vitalograph alpha Touch™ spirometer in evaluating lung function in healthy individuals, asthmatics, and COPD patients-a randomized, crossover study.
    Talwar D; Balamurugan S; Modi M; Salvi S; Lopez M; Shah R; Vaidya A; Barne M; Madas S; Kulkarni N; Sawant S; Gogtay J
    BMC Pulm Med; 2024 May; 24(1):230. PubMed ID: 38730359
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Calibration of time derivatives of forced vital capacity by explosive decompression.
    Petusevsky ML; Lyons LD; Smith AA; Epler GR; Gaensler EA
    Am Rev Respir Dis; 1980 Feb; 121(2):343-50. PubMed ID: 7362141
    [TBL] [Abstract][Full Text] [Related]  

  • 28. An Interrater Reliability Study of Pulmonary Function Assessment With a Portable Spirometer.
    Zhang H; Li L; Jiao D; Yang Y; Pan C; Ye L; Wei S; Jin M
    Respir Care; 2020 May; 65(5):665-672. PubMed ID: 32019850
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Clinical validation of the Welch-Allyn Pneumocheck hand held spirometer.
    Barkley B; Lichtenstein MJ; Garza C; Hazuda HP
    Am J Med Sci; 1994 Dec; 308(6):357-9. PubMed ID: 7985725
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Volume spirometers need automated internal temperature sensors.
    Johnson LR; Enright PL; Voelker HT; Tashkin DP
    Am J Respir Crit Care Med; 1994 Dec; 150(6 Pt 1):1575-80. PubMed ID: 7952617
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Evaluation of a hand-held spirometer, the Respiradyne, for the measurement of forced expiratory volume in the first second (FEV1), forced vital capacity (FVC) and peak expiratory flow rate (PEFR) (1).
    Respir Med; 1989 Mar; 83(2):167-9. PubMed ID: 2602603
    [No Abstract]   [Full Text] [Related]  

  • 32. Comparison of a handheld turbine spirometer to conventional spirometry in children with cystic fibrosis.
    Avdimiretz N; Wilson D; Grasemann H
    Pediatr Pulmonol; 2020 Jun; 55(6):1394-1399. PubMed ID: 32203645
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Measurement of FEV1 and FVC. Comparison of a pocket spirometer with the Vitalograph.
    Hosie HE; Nimmo WS
    Anaesthesia; 1988 Mar; 43(3):233-8. PubMed ID: 3364644
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A comparison of spirometric values with subjects in standing and sitting positions.
    Pierson DJ; Dick NP; Petty TL
    Chest; 1976 Jul; 70(1):17-20. PubMed ID: 1277923
    [TBL] [Abstract][Full Text] [Related]  

  • 35. The Spirostat: comparison with water-sealed spirometer.
    Gold MI; Feldman I; Hebel JR
    Crit Care Med; 1975; 3(4):155-8. PubMed ID: 1192752
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Reproducibility and validity of a handheld spirometer.
    Barr RG; Stemple KJ; Mesia-Vela S; Basner RC; Derk SJ; Henneberger PK; Milton DK; Taveras B
    Respir Care; 2008 Apr; 53(4):433-41. PubMed ID: 18364054
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of breathing circuit resistance on the measurement of ventilatory function.
    Johns DP; Ingram CM; Khov S; Rochford PD; Walters EH
    Thorax; 1998 Nov; 53(11):944-8. PubMed ID: 10193392
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Effects of temperature on Vitalograph spirometer readings.
    Perks WH; Sopwith T; Brown D; Jones CH; Green M
    Thorax; 1983 Aug; 38(8):592-4. PubMed ID: 6612650
    [TBL] [Abstract][Full Text] [Related]  

  • 39. An evaluation of the P.K. Morgan pocket spirometer.
    Hess D; Lehman E; Troup J; Smoker J
    Respir Care; 1986 Sep; 31(9):786-91. PubMed ID: 10315706
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of a new desktop spirometer (Spirospec) with a laboratory spirometer in a respiratory out-patient clinic.
    Swart F; Schuurmans MM; Heydenreich JC; Pieper CH; Bolliger CT
    Respir Care; 2003 Jun; 48(6):591-5. PubMed ID: 12780945
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.