These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

91 related articles for article (PubMed ID: 12616416)

  • 1. Intense inflammatory reaction to heparin polymer coated intravascular Palmaz stents in porcine arteries compared to uncoated Palmaz stents.
    Goodwin SC; Yoon HC; Chen G; Abdel-Sayed P; Costantino MM; Bonilla SM; Nishimura E
    Cardiovasc Intervent Radiol; 2003; 26(2):158-67. PubMed ID: 12616416
    [TBL] [Abstract][Full Text] [Related]  

  • 2. In vivo model of intracranial stent implantation: a pilot study to examine the histological response of cerebral vessels after randomized implantation of heparin-coated and uncoated endoluminal stents in a blinded fashion.
    Levy EI; Boulos AS; Hanel RA; Tio FO; Alberico RA; Fronckowiak MD; Nemes B; Paciorek AM; Guterman LR; Hopkins LN
    J Neurosurg; 2003 Mar; 98(3):544-53. PubMed ID: 12650426
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Heparin-coated versus uncoated Palmaz-Schatz stent in native coronary circulation. A randomized study with blind angioscopic assessment.
    Kedev S; Guagliumi G; Valsechi O; Tespili M
    Int J Artif Organs; 2002 May; 25(5):461-9. PubMed ID: 12074345
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Preventive effects of the heparin-coated stent on restenosis in the porcine model.
    Ahn YK; Jeong MH; Kim JW; Kim SH; Cho JH; Cho JG; Park CS; Juhng SW; Park JC; Kang JC
    Catheter Cardiovasc Interv; 1999 Nov; 48(3):324-30. PubMed ID: 10525239
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Advanced c-myc antisense (AVI-4126)-eluting phosphorylcholine-coated stent implantation is associated with complete vascular healing and reduced neointimal formation in the porcine coronary restenosis model.
    Kipshidze NN; Iversen P; Kim HS; Yiazdi H; Dangas G; Seaborn R; New G; Tio F; Waksman R; Mehran R; Tsapenko M; Stone GW; Roubin GS; Iyer S; Leon MB; Moses JW
    Catheter Cardiovasc Interv; 2004 Apr; 61(4):518-27. PubMed ID: 15065150
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Sustained increased risk of adverse cardiac events over 5 years after implantation of gold-coated coronary stents.
    Pache J; Dibra A; Schaut C; Schühlen H; Dirschinger J; Mehilli J; Kastrati A; Schömig A
    Catheter Cardiovasc Interv; 2006 Nov; 68(5):690-5. PubMed ID: 17039510
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Restenosis following placement of an intracoronary heparin treated tantulum stent in the hyperlipidemic miniature swine model.
    Jenkins JS; Webel R; Laughlin MH; Rowland SM; Yoklavich MF; Amann JF; Branson K; Myers PR
    J Invasive Cardiol; 1995; 7(6):173-82. PubMed ID: 10155102
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the biocompatibility of two new diamond-like stent coatings (Dylyn) in a porcine coronary stent model.
    De Scheerder I; Szilard M; Yanming H; Ping XB; Verbeken E; Neerinck D; Demeyere E; Coppens W; Van de Werf F
    J Invasive Cardiol; 2000 Aug; 12(8):389-94. PubMed ID: 10953100
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Local methylprednisolone delivery using a BiodivYsio phosphorylcholine-coated drug-delivery stent reduces inflammation and neointimal hyperplasia in a porcine coronary stent model.
    Huang Y; Liu X; Wang L; Verbeken E; Li S; De Scheerder I
    Int J Cardiovasc Intervent; 2003; 5(3):166-71. PubMed ID: 12959735
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Optimization of local methylprednisolone delivery to inhibit inflammatory reaction and neointimal hyperplasia of coated coronary stents.
    Huang Y; Wang L; Verweire I; Qiang B; Liu X; Verbeken E; Schacht E; De Scheerder I
    J Invasive Cardiol; 2002 Sep; 14(9):505-13. PubMed ID: 12205348
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Phosphorylcholine-coated stents in porcine coronary arteries: in vivo assessment of biocompatibility.
    Malik N; Gunn J; Shepherd L; Crossman DC; Cumberland DC; Holt CM
    J Invasive Cardiol; 2001 Mar; 13(3):193-201. PubMed ID: 11231644
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Phosphorylcholine-coated metallic stents in rabbit iliac and porcine coronary arteries.
    Kuiper KK; Robinson KA; Chronos NA; Cui J; Palmer SJ; Nordrehaug JE
    Scand Cardiovasc J; 1998; 32(5):261-8. PubMed ID: 9834999
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Comparison of the heparin coated vs the uncoated Jostent--no influence on restenosis or clinical outcome.
    Wöhrle J; Al-Khayer E; Grötzinger U; Schindler C; Kochs M; Hombach V; Höher M
    Eur Heart J; 2001 Oct; 22(19):1808-16. PubMed ID: 11549303
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biocompatibility of polymer-coated oversized metallic stents implanted in normal porcine coronary arteries.
    De Scheerder IK; Wilczek KL; Verbeken EV; Vandorpe J; Lan PN; Schacht E; De Geest H; Piessens J
    Atherosclerosis; 1995 Apr; 114(1):105-14. PubMed ID: 7605369
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Permanent and biodegradable polymer coatings in the absence of antiproliferative drugs in a porcine model of coronary artery stenting.
    Koppara T; Wittchow E; Byrne RA; Bayer G; Diener T; Joner M
    EuroIntervention; 2016 Jan; 11(9):1020-6. PubMed ID: 25317851
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Novel biodegradable polymer-coated, paclitaxel-eluting stent inhibits neointimal formation in porcine coronary arteries.
    Buszman P; Milewski K; Zurakowski A; Pajak J; Liszka Ł; Buszman P; Musioł E; AbuSamra M; Trznadel S; Kałuza G
    Kardiol Pol; 2010 May; 68(5):503-9. PubMed ID: 20491008
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Iliac anastomotic stenting with a sirolimus-eluting biodegradable poly-L-lactide stent: a preliminary study after 6 weeks.
    Bünger CM; Grabow N; Kröger C; Lorenzen B; Hauenstein K; Goosmann M; Schmitz KP; Kreutzer HJ; Lootz D; Ince H; Nienaber CA; Klar E; Schareck W; Sternberg K
    J Endovasc Ther; 2006 Oct; 13(5):630-9. PubMed ID: 17042669
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Catheter-based 32P beta-radiation after stent implantation in porcine coronary arteries: role of source-centering and geographical miss.
    Maeng M; Busk M; Tanderup K; Mertz H; Andersen HR; Thuesen L
    Catheter Cardiovasc Interv; 2003 Oct; 60(2):247-57. PubMed ID: 14517934
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A novel paclitaxel-eluting porous carbon-carbon nanoparticle coated, nonpolymeric cobalt-chromium stent: evaluation in a porcine model.
    Bhargava B; Reddy NK; Karthikeyan G; Raju R; Mishra S; Singh S; Waksman R; Virmani R; Somaraju B
    Catheter Cardiovasc Interv; 2006 May; 67(5):698-702. PubMed ID: 16575925
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fibrin sealant coated stents compared with non-coated stents in a porcine carotid artery model. Preliminary study report.
    Byer A; Peters S; Settepani F; Pagliaro M; Galletti G
    J Cardiovasc Surg (Torino); 2001 Aug; 42(4):543-9. PubMed ID: 11455294
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 5.