These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

218 related articles for article (PubMed ID: 12620786)

  • 41. TKA design-integrated trochlea groove rotation reduces patellofemoral pressure.
    Woiczinski M; Kistler M; Schröder C; Braun C; Weber P; Müller PE; Jansson V; Steinbrück A
    Knee Surg Sports Traumatol Arthrosc; 2019 May; 27(5):1680-1692. PubMed ID: 30564858
    [TBL] [Abstract][Full Text] [Related]  

  • 42. International comparative evaluation of knee replacement with fixed or mobile-bearing posterior-stabilized prostheses.
    Graves S; Sedrakyan A; Baste V; Gioe TJ; Namba R; Martínez Cruz O; Stea S; Paxton E; Banerjee S; Isaacs AJ; Robertsson O
    J Bone Joint Surg Am; 2014 Dec; 96 Suppl 1(Suppl 1):59-64. PubMed ID: 25520420
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Influence of mediolateral tibial baseplate position in TKA on knee kinematics and retropatellar pressure.
    Steinbrück A; Fottner A; Schröder C; Woiczinski M; Schmitt-Sody M; Müller T; Müller PE; Jansson V
    Knee Surg Sports Traumatol Arthrosc; 2017 Aug; 25(8):2602-2608. PubMed ID: 26531185
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Mobile-bearing total knee arthroplasty improves patellar tracking and patellofemoral contact stress: in vivo measurements in the same patients.
    Sawaguchi N; Majima T; Ishigaki T; Mori N; Terashima T; Minami A
    J Arthroplasty; 2010 Sep; 25(6):920-5. PubMed ID: 19775856
    [TBL] [Abstract][Full Text] [Related]  

  • 45. Mobile-bearing insert reduced patellar contact force at knee flexion during posterior stabilized total knee arthroplasty.
    Kuroda Y; Takayama K; Hayashi S; Hashimoto S; Tsubosaka M; Kamenaga T; Matsushita T; Niikura T; Kuroda R; Matsumoto T
    Clin Biomech (Bristol, Avon); 2020 Jun; 76():105022. PubMed ID: 32388495
    [TBL] [Abstract][Full Text] [Related]  

  • 46. The effect of surgical alignment and soft tissue conditions on the kinematics and wear of a fixed bearing total knee replacement.
    Johnston H; Abdelgaied A; Pandit H; Fisher J; Jennings LM
    J Mech Behav Biomed Mater; 2019 Dec; 100():103386. PubMed ID: 31408775
    [TBL] [Abstract][Full Text] [Related]  

  • 47. LCS mobile-bearing total knee replacement. A 10-year's follow-up study.
    Vogt JC; Saarbach C
    Orthop Traumatol Surg Res; 2009 May; 95(3):177-82. PubMed ID: 19328763
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Spherical center axial hinge knee prosthesis causes lower contact stress on tibial insert and bushing compared with biaxial hinge knee prosthesis.
    Zhang JY; Zhang HR; Tian DM; Wang F; Zhang H; Hu YC
    Knee; 2021 Mar; 29():1-8. PubMed ID: 33524657
    [TBL] [Abstract][Full Text] [Related]  

  • 49. International comparative evaluation of knee replacement with fixed or mobile non-posterior-stabilized implants.
    Namba R; Graves S; Robertsson O; Furnes O; Stea S; Puig-Verdié L; Hoeffel D; Cafri G; Paxton E; Sedrakyan A
    J Bone Joint Surg Am; 2014 Dec; 96 Suppl 1(Suppl 1):52-8. PubMed ID: 25520419
    [TBL] [Abstract][Full Text] [Related]  

  • 50. In vivo anterior tibial post contact after posterior stabilizing total knee arthroplasty.
    Hanson GR; Suggs JF; Kwon YM; Freiberg AA; Li G
    J Orthop Res; 2007 Nov; 25(11):1447-53. PubMed ID: 17557322
    [TBL] [Abstract][Full Text] [Related]  

  • 51. In vivo kinematics of a low contact stress rotating platform total knee arthroplasty system under weight bearing and non-weight bearing condition.
    Matsumoto K; Iwamoto K; Mori N; Yamasaki T; Ito Y; Takigami I; Terabayashi N; Ogawa H; Tomita T; Akiyama H
    J Orthop Sci; 2014 Sep; 19(5):750-5. PubMed ID: 24996622
    [TBL] [Abstract][Full Text] [Related]  

  • 52. The kinematics of fixed- and mobile-bearing total knee arthroplasty.
    Most E; Li G; Schule S; Sultan P; Park SE; Zayontz S; Rubash HE
    Clin Orthop Relat Res; 2003 Nov; (416):197-207. PubMed ID: 14646762
    [TBL] [Abstract][Full Text] [Related]  

  • 53. A kinematic comparison of fixed- and mobile-bearing knee replacements.
    Delport HP; Banks SA; De Schepper J; Bellemans J
    J Bone Joint Surg Br; 2006 Aug; 88(8):1016-21. PubMed ID: 16877599
    [TBL] [Abstract][Full Text] [Related]  

  • 54. An optimization method for implantation parameters of individualized TKA tibial prosthesis based on finite element analysis and orthogonal experimental design.
    Dong Y; Zhang Z; Dong W; Hu G; Wang B; Mou Z
    BMC Musculoskelet Disord; 2020 Mar; 21(1):165. PubMed ID: 32164625
    [TBL] [Abstract][Full Text] [Related]  

  • 55. Fixed and mobile-bearing total ankle prostheses: Effect on tibial bone strain.
    Terrier A; Fernandes CS; Guillemin M; Crevoisier X
    Clin Biomech (Bristol, Avon); 2017 Oct; 48():57-62. PubMed ID: 28755611
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Mobile-bearing total knee arthroplasty: a full traumatic rotation of 180°.
    Sudanese A; Castiello E; Affatato S
    Int J Artif Organs; 2013 Jun; 36(6):421-5. PubMed ID: 23653296
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Impact of tibial baseplate malposition on kinematics, contact forces and ligament tensions in TKA: A numerical analysis.
    Fottner A; Woiczinski M; Schröder C; Schmidutz F; Weber P; Müller PE; Jansson V; Steinbrück A
    J Mech Behav Biomed Mater; 2020 Mar; 103():103564. PubMed ID: 32090954
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Mobile bearings in primary knee arthroplasty.
    Vertullo CJ; Easley ME; Scott WN; Insall JN
    J Am Acad Orthop Surg; 2001; 9(6):355-64. PubMed ID: 11730328
    [TBL] [Abstract][Full Text] [Related]  

  • 59. Modifications of femoral component design in multi-radius total knee arthroplasty lead to higher lateral posterior femoro-tibial translation.
    Pfitzner T; Moewis P; Stein P; Boeth H; Trepczynski A; von Roth P; Duda GN
    Knee Surg Sports Traumatol Arthrosc; 2018 Jun; 26(6):1645-1655. PubMed ID: 28656456
    [TBL] [Abstract][Full Text] [Related]  

  • 60. In vivo kinematic analysis of a mobile bearing total knee prosthesis.
    Stiehl JB; Dennis DA; Komistek RD; Keblish PA
    Clin Orthop Relat Res; 1997 Dec; (345):60-6. PubMed ID: 9418622
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 11.