BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

145 related articles for article (PubMed ID: 12621758)

  • 1. [Pseudoaneurysm of arteriovenous fistula for haemodialysis].
    Kade G; Zagrodzka M; Prokopiuk M; Wierzbicki P; Dziekiewicz M; Wańkowicz Z
    Pol Merkur Lekarski; 2002 Nov; 13(77):399-402. PubMed ID: 12621758
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [New diagnostic and therapeutic methods in pseudoaneurysm of arterio-venous fistula for hemodialysis--case report].
    Kade G; Wierzbicki P; Prokopiuk-Wierzbicka M; Jaroń B; Zagrodzka M; Włodarski J
    Pol Merkur Lekarski; 2004 Aug; 17(98):148-50. PubMed ID: 15603324
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Emergency ultrasound diagnosis of a pseudoaneurysm associated with an arteriovenous fistula.
    Arshad FH; Sutijono D; Moore CL
    Acad Emerg Med; 2010 Jun; 17(6):e43-5. PubMed ID: 20491681
    [No Abstract]   [Full Text] [Related]  

  • 4. Venous pseudoaneurysm as a late complication of hemodialysis.
    Radmili O; Vasic D; Vranes M; Banzic I; Cvetic V; Davidovic L
    Am Surg; 2012 May; 78(5):E270-2. PubMed ID: 22546102
    [No Abstract]   [Full Text] [Related]  

  • 5. Giant pseudoaneurysm of an autologous arteriovenous fistula in the forearm: surgical repair.
    González López MT; González González S; Muñoz García RJ; Ramos Frendo B; Aranda Granados PJ; Gutiérrez de Loma J
    Nefrologia; 2011; 31(4):499-500. PubMed ID: 21738259
    [No Abstract]   [Full Text] [Related]  

  • 6. Successful ultrasonographically guided compression repair of a dialysis fistula pseudoaneurysm.
    Zehnder T; Chatterjee T; Mahler F; Do DD
    J Ultrasound Med; 2000 May; 19(5):329-31. PubMed ID: 10811406
    [No Abstract]   [Full Text] [Related]  

  • 7. Emergency brachial artery ligation for ruptured infected pseudoaneurysm of haemodialysis access is a possible option.
    Bishnoi AK; Rai G; Kamath GS; Vishnu R; Kumar V; Joshi H; Prabhu R; Soni LP; Nasser A
    J Vasc Access; 2019 Sep; 20(5):471-474. PubMed ID: 30486731
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Diagnosis of an Arteriovenous (AV) Graft Pseudoaneurysm by Bedside Ultrasound in the Emergency Department.
    Marx JT; Virkler J
    J Emerg Med; 2016 Feb; 50(2):330-2. PubMed ID: 26481782
    [No Abstract]   [Full Text] [Related]  

  • 9. Acute haemorrhage secondary to arteriovenous haemodialysis fistula pseudoaneurysm--the challenge of restoring a deformed upper limb.
    Salamon T; Safadi W; Izakson A
    BMJ Case Rep; 2015 Jul; 2015():. PubMed ID: 26153288
    [No Abstract]   [Full Text] [Related]  

  • 10. Pseudoaneurysm of an arteriovenous dialysis graft.
    Cook DT; Powell JT; Schofer JM; Sierzenski PR; Nomura JT
    J Emerg Med; 2012 Mar; 42(3):e65-6. PubMed ID: 20045602
    [No Abstract]   [Full Text] [Related]  

  • 11. [Angioradiology as diagnosis and treatment of a pseudoaneurysm in an internal arteriovenous fistula].
    Pou M; Saurina A; Falcó J; de las Cuevas X
    Nefrologia; 2004; 24(4):380-1. PubMed ID: 15455501
    [No Abstract]   [Full Text] [Related]  

  • 12. Brachial artery pseudoaneurysm: a rare complication after haemodialysis therapy.
    Yildirim S; Nursal TZ; Yildirim T; Tarim A; Caliskan K
    Acta Chir Belg; 2005 Apr; 105(2):190-3. PubMed ID: 15906913
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Arteriovenous fistula buttonhole cannulation: early experience in an Irish haemodialysis unit.
    Ward F; Holian J; Watson A
    Nephrol Dial Transplant; 2011 Nov; 26(11):3825; author reply 1825-6. PubMed ID: 21873344
    [No Abstract]   [Full Text] [Related]  

  • 14. Nonoperative salvage of an aneurysmal arteriovenous fistula.
    Shrikhande A; Muhs BE; Sergi MA; Brewster UC
    Semin Dial; 2009; 22(1):97-8. PubMed ID: 19175536
    [No Abstract]   [Full Text] [Related]  

  • 15. Salvaging the 'life-threatening life line': repair not recreate.
    Adnan AS; Khan YH; Sarriff A; Khan AH
    Br J Hosp Med (Lond); 2016 Apr; 77(4):252. PubMed ID: 27071436
    [No Abstract]   [Full Text] [Related]  

  • 16. [Brachial artery pseudoaneurysm: a rare but serious complication in hemodialysis patients with arteriovenous fistula].
    Mancini A; Castriotta G; Angelini P; Bozzi M; Giancaspro V; La Raia E; Nisi MT; Proscia AR; Tarantino G; Vitale O; Cuzzola C
    G Ital Nefrol; 2017 Jun; 34(3):44-53. PubMed ID: 28700182
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Arteriovenous fistulae for chronic haemodialysis. Report on 400 patients].
    Ribet M; Chambon JP; Duval G
    J Chir (Paris); 1982; 119(6-7):429-36. PubMed ID: 7119031
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Rupture of an infectious pseudoaneurysm of the aortic arch in an end-stage renal failure patient with chronic hemodialysis.
    Chung S; Choi DE; Na KR; Lee KW
    Clin Nephrol; 2015 Jul; 84(1):39-43. PubMed ID: 26042414
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A rare case of iatrogenic pseudoaneurysm of the left brachiocephalic vein after central venous catheterization treated with thrombin injection.
    Elsaadany AM; Alaeddin FH; Alsuhaibani HA
    Cardiovasc Intervent Radiol; 2014 Aug; 37(4):1083-6. PubMed ID: 24042960
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Giant true aneurysm of the radial artery following ligation of an arteriovenous fistula for haemodialysis.
    Feijoo-Cano C;
    Nefrologia; 2012 May; 32(3):404-6. PubMed ID: 22592432
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 8.