These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

127 related articles for article (PubMed ID: 12622370)

  • 21. Development and validation of a highly sensitive and robust LC-MS/MS with electrospray ionization method for quantification of rosuvastatin in small volume human plasma samples and its application to a clinical study.
    Kallem RR; Karthik A; Chakradhar L; Mullangi R; Srinivas NR
    Arzneimittelforschung; 2007; 57(11):705-11. PubMed ID: 18193692
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Fully-automated chip-based nanoelectrospray tandem mass spectrometry of gangliosides from human cerebellum.
    Zamfir A; Vukelić Z; Bindila L; Peter-Katalinić J; Almeida R; Sterling A; Allen M
    J Am Soc Mass Spectrom; 2004 Nov; 15(11):1649-57. PubMed ID: 15519233
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Chip-based quantitative capillary electrophoresis/mass spectrometry determination of drugs in human plasma.
    Deng Y; Zhang H; Henion J
    Anal Chem; 2001 Apr; 73(7):1432-9. PubMed ID: 11321291
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Verapamil quantification in human plasma by liquid chromatography coupled to tandem mass spectrometry. An application for bioequivalence study.
    do C Borges NC; Mendes GD; Barrientos-Astigarraga RE; Galvinas P; Oliveira CH; De Nucci G
    J Chromatogr B Analyt Technol Biomed Life Sci; 2005 Dec; 827(2):165-72. PubMed ID: 16203182
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Simultaneous quantification of cyclophosphamide, 4-hydroxycyclophosphamide, N,N',N"-triethylenethiophosphoramide (thiotepa) and N,N',N"-triethylenephosphoramide (tepa) in human plasma by high-performance liquid chromatography coupled with electrospray ionization tandem mass spectrometry.
    de Jonge ME; van Dam SM; Hillebrand MJ; Rosing H; Huitema AD; Rodenhuis S; Beijnen JH
    J Mass Spectrom; 2004 Mar; 39(3):262-71. PubMed ID: 15039933
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Investigation of an enhanced resolution triple quadrupole mass spectrometer for high-throughput liquid chromatography/tandem mass spectrometry assays.
    Yang L; Amad M; Winnik WM; Schoen AE; Schweingruber H; Mylchreest I; Rudewicz PJ
    Rapid Commun Mass Spectrom; 2002; 16(21):2060-6. PubMed ID: 12391581
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Increased productivity in quantitative bioanalysis using a monolithic column coupled with high-flow direct-injection liquid chromatography/tandem mass spectrometry.
    Huang MQ; Mao Y; Jemal M; Arnold M
    Rapid Commun Mass Spectrom; 2006; 20(11):1709-14. PubMed ID: 16676309
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Reliable and Easy-To-Use Liquid Chromatography-Tandem Mass Spectrometry Method for Simultaneous Analysis of Fluconazole, Isavuconazole, Itraconazole, Hydroxy-Itraconazole, Posaconazole, and Voriconazole in Human Plasma and Serum.
    Müller C; Gehlen D; Blaich C; Prozeller D; Liss B; Streichert T; Wiesen MHJ
    Ther Drug Monit; 2017 Oct; 39(5):505-513. PubMed ID: 28742650
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Systematic evaluation of supported liquid extraction in reducing matrix effect and improving extraction efficiency in LC-MS/MS based bioanalysis for 10 model pharmaceutical compounds.
    Jiang H; Cao H; Zhang Y; Fast DM
    J Chromatogr B Analyt Technol Biomed Life Sci; 2012 Apr; 891-892():71-80. PubMed ID: 22410088
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Reliable and easy-to-use LC-MS/MS-method for simultaneous determination of the antihypertensives metoprolol, amlodipine, canrenone and hydrochlorothiazide in patients with therapy-refractory arterial hypertension.
    Johannsen JO; Reuter H; Hoffmann F; Blaich C; Wiesen MHJ; Streichert T; Müller C
    J Pharm Biomed Anal; 2019 Feb; 164():373-381. PubMed ID: 30439665
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Development and validation of a rapid LC-MS/MS method to quantify letrozole in human plasma and its application to therapeutic drug monitoring.
    Shao R; Yu LY; Lou HG; Ruan ZR; Jiang B; Chen JL
    Biomed Chromatogr; 2016 Apr; 30(4):632-7. PubMed ID: 26317321
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Rapid, accurate and precise quantitative drug analysis: comparing liquid chromatography tandem mass spectrometry and chip-based nanoelectrospray ionisation mass spectrometry.
    Alfazema LN; Richards DS; Gélébart S; Mitchell JC; Snowden MJ
    Eur J Mass Spectrom (Chichester); 2005; 11(4):393-402. PubMed ID: 16204806
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Ultralow-volume fraction collection from NanoLC columns for mass spectrometric analysis of protein phosphorylation and glycosylation.
    Corso TN; Van Pelt CK; Li J; Ptak C; Huang X
    Anal Chem; 2006 Apr; 78(7):2209-19. PubMed ID: 16579599
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Development and validation of a liquid chromatography/tandem mass spectrometry assay for the simultaneous determination of D-amphetamine and diphenhydramine in beagle dog plasma and its application to a pharmacokinetic study.
    Wang C; Fan G; Lin M; Chen Y; Zhao W; Wu Y
    J Chromatogr B Analyt Technol Biomed Life Sci; 2007 Jul; 854(1-2):48-56. PubMed ID: 17452029
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Validation of an electrospray ionization LC-MS/MS method for quantitative analysis of raltegravir, etravirine, and 9 other antiretroviral agents in human plasma samples.
    Quaranta S; Woloch C; Paccou A; Giocanti M; Solas C; Lacarelle B
    Ther Drug Monit; 2009 Dec; 31(6):695-702. PubMed ID: 19865000
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Development and validation of a high-throughput method for the quantitative analysis of D-amphetamine in rat blood using liquid chromatography/MS3 on a hybrid triple quadrupole-linear ion trap mass spectrometer and its application to a pharmacokinetic study.
    Cesari N; Fontana S; Montanari D; Braggio S
    J Chromatogr B Analyt Technol Biomed Life Sci; 2010 Jan; 878(1):21-8. PubMed ID: 19945359
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Development of a low volume plasma sample precipitation procedure for liquid chromatography/tandem mass spectrometry assays used for drug discovery applications.
    Xu X; Zhou Q; Korfmacher WA
    Rapid Commun Mass Spectrom; 2005; 19(15):2131-6. PubMed ID: 15988723
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Quantitative analysis of the novel anticancer drug ABT-518, a matrix metalloproteinase inhibitor, plus the screening of six metabolites in human plasma using high-performance liquid chromatography coupled with electrospray tandem mass spectrometry.
    Stokvis E; Rosing H; Crul M; Rieser MJ; Heck AJ; Schellens JH; Beijnen JH
    J Mass Spectrom; 2004 Mar; 39(3):277-88. PubMed ID: 15039935
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Laser diode thermal desorption atmospheric pressure chemical ionization tandem mass spectrometry applied for the ultra-fast quantitative analysis of BKM120 in human plasma.
    Lanshoeft C; Heudi O; Leuthold LA; Schlotterbeck G; Elbast W; Picard F; Kretz O
    Anal Bioanal Chem; 2014 Sep; 406(22):5413-23. PubMed ID: 24958346
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Development and validation of a high-throughput and robust LC-MS/MS with electrospray ionization method for simultaneous quantitation of oseltamivir phosphate and its oseltamivir carboxylate metabolite in human plasma for pharmacokinetic studies.
    Kanneti R; Bhavesh D; Paramar D; R S; Bhatt PA
    Biomed Chromatogr; 2011 Jun; 25(6):727-33. PubMed ID: 20845365
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.