These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

178 related articles for article (PubMed ID: 12625866)

  • 1. Characterisation and evaluation of novel surfactant bacterial anti-adherent coatings for endotracheal tubes designed for the prevention of ventilator-associated pneumonia.
    Jones DS; McMeel S; Adair CG; Gorman SP
    J Pharm Pharmacol; 2003 Jan; 55(1):43-52. PubMed ID: 12625866
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Role of physiological conditions in the oropharynx on the adherence of respiratory bacterial isolates to endotracheal tube poly(vinyl chloride).
    Jones DS; McGovern JG; Woolfson AD; Gorman SP
    Biomaterials; 1997 Mar; 18(6):503-10. PubMed ID: 9111955
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hydrogel Antimicrobial Capture Coatings for Endotracheal Tubes: A Pharmaceutical Strategy Designed to Prevent Ventilator-Associated Pneumonia.
    Jones DS; McCoy CP; Andrews GP; McCrory RM; Gorman SP
    Mol Pharm; 2015 Aug; 12(8):2928-36. PubMed ID: 26111258
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Physicochemical characterization of hexetidine-impregnated endotracheal tube poly(vinyl chloride) and resistance to adherence of respiratory bacterial pathogens.
    Jones DS; McGovern JG; Woolfson AD; Adair CG; Gorman SP
    Pharm Res; 2002 Jun; 19(6):818-24. PubMed ID: 12134952
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The concomitant development of poly(vinyl chloride)-related biofilm and antimicrobial resistance in relation to ventilator-associated pneumonia.
    Gorman SP; McGovern JG; Woolfson AD; Adair CG; Jones DS
    Biomaterials; 2001 Oct; 22(20):2741-7. PubMed ID: 11545308
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Co-immobilization of Ciprofloxacin and Chlorhexidine as a Broad-Spectrum Antimicrobial Dual-Drug Coating for Poly(vinyl chloride) (PVC)-Based Endotracheal Tubes.
    Alves DF; Pereira MO; Lopes SP
    ACS Appl Mater Interfaces; 2024 Apr; 16(13):16861-16879. PubMed ID: 38507790
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Activity of a silver-coated endotracheal tube in preclinical models of ventilator-associated pneumonia and a study after extubation.
    Rello J; Afessa B; Anzueto A; Arroliga AC; Olson ME; Restrepo MI; Talsma SS; Bracken RL; Kollef MH
    Crit Care Med; 2010 Apr; 38(4):1135-40. PubMed ID: 20081533
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biofilm formation on three different endotracheal tubes: a prospective clinical trial.
    Thorarinsdottir HR; Kander T; Holmberg A; Petronis S; Klarin B
    Crit Care; 2020 Jun; 24(1):382. PubMed ID: 32600373
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Silver-coated endotracheal tubes and incidence of ventilator-associated pneumonia: the NASCENT randomized trial.
    Kollef MH; Afessa B; Anzueto A; Veremakis C; Kerr KM; Margolis BD; Craven DE; Roberts PR; Arroliga AC; Hubmayr RD; Restrepo MI; Auger WR; Schinner R;
    JAMA; 2008 Aug; 300(7):805-13. PubMed ID: 18714060
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Sphingosine-coating of plastic surfaces prevents ventilator-associated pneumonia.
    Seitz AP; Schumacher F; Baker J; Soddemann M; Wilker B; Caldwell CC; Gobble RM; Kamler M; Becker KA; Beck S; Kleuser B; Edwards MJ; Gulbins E
    J Mol Med (Berl); 2019 Aug; 97(8):1195-1211. PubMed ID: 31222488
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Implications and emerging control strategies for ventilator-associated infections.
    Loo CY; Lee WH; Young PM; Cavaliere R; Whitchurch CB; Rohanizadeh R
    Expert Rev Anti Infect Ther; 2015 Mar; 13(3):379-93. PubMed ID: 25632800
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Adhesion of Pseudomonas aeruginosa strains to untreated and oxygen-plasma treated poly(vinyl chloride) (PVC) from endotracheal intubation devices.
    Triandafillu K; Balazs DJ; Aronsson BO; Descouts P; Tu Quoc P; van Delden C; Mathieu HJ; Harms H
    Biomaterials; 2003 Apr; 24(8):1507-18. PubMed ID: 12527292
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Preclinical testing of a broad-spectrum antimicrobial endotracheal tube coated with an innate immune synthetic mimic.
    Hashemi MM; Rovig J; Bateman J; Holden BS; Modelzelewski T; Gueorguieva I; von Dyck M; Bracken R; Genberg C; Deng S; Savage PB
    J Antimicrob Chemother; 2018 Jan; 73(1):143-150. PubMed ID: 29029265
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Polyurethane cuffed endotracheal tubes to prevent early postoperative pneumonia after cardiac surgery: a pilot study.
    Poelaert J; Depuydt P; De Wolf A; Van de Velde S; Herck I; Blot S
    J Thorac Cardiovasc Surg; 2008 Apr; 135(4):771-6. PubMed ID: 18374755
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A rapid method of impregnating endotracheal tubes and urinary catheters with gendine: a novel antiseptic agent.
    Chaiban G; Hanna H; Dvorak T; Raad I
    J Antimicrob Chemother; 2005 Jan; 55(1):51-6. PubMed ID: 15574478
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Inhibition of bacterial adhesion on PVC endotracheal tubes by RF-oxygen glow discharge, sodium hydroxide and silver nitrate treatments.
    Balazs DJ; Triandafillu K; Wood P; Chevolot Y; van Delden C; Harms H; Hollenstein C; Mathieu HJ
    Biomaterials; 2004 May; 25(11):2139-51. PubMed ID: 14741629
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Cost-effectiveness analysis of a silver-coated endotracheal tube to reduce the incidence of ventilator-associated pneumonia.
    Shorr AF; Zilberberg MD; Kollef M
    Infect Control Hosp Epidemiol; 2009 Aug; 30(8):759-63. PubMed ID: 19538095
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Coating polyvinylchloride surface for improved antifouling property.
    Wen X; Almousa R; Anderson G; Na S; Xie D
    J Biomater Sci Polym Ed; 2019 Mar; 30(4):322-336. PubMed ID: 30688167
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Superhydrophobic, nanotextured polyvinyl chloride films for delaying Pseudomonas aeruginosa attachment to intubation tubes and medical plastics.
    Loo CY; Young PM; Lee WH; Cavaliere R; Whitchurch CB; Rohanizadeh R
    Acta Biomater; 2012 May; 8(5):1881-90. PubMed ID: 22330278
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Antimicrobial Coating Prevents Ventilator-Associated Pneumonia in a 72 hour Large Animal Model.
    Seitz A; Baker JE; Levinsky NC; Morris MC; Edwards MJ; Gulbins E; Blakeman TC; Rodriquez D; Branson RD; Goodman M
    J Surg Res; 2021 Nov; 267():424-431. PubMed ID: 34229130
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.