These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
194 related articles for article (PubMed ID: 12630749)
1. Reply to 'Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry''. MacDougall ND; Pitchford WG; Smith MA Phys Med Biol; 2003 Feb; 48(4):L19-22. PubMed ID: 12630749 [No Abstract] [Full Text] [Related]
2. Comment on 'A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and fricke MRI gel dosimetry'. De Deene Y; De Wagter C; Baldock C Phys Med Biol; 2003 Feb; 48(3):L15-8. PubMed ID: 12608618 [No Abstract] [Full Text] [Related]
3. A systematic review of the precision and accuracy of dose measurements in photon radiotherapy using polymer and Fricke MRI gel dosimetry. MacDougall ND; Pitchford WG; Smith MA Phys Med Biol; 2002 Oct; 47(20):R107-21. PubMed ID: 12433119 [TBL] [Abstract][Full Text] [Related]
4. Spatial resolution of magnetic resonance imaging Fricke-gel dosimetry is improved with a honeycomb phantom. Silva NA; Nicolucci P; Baffa O Med Phys; 2003 Jan; 30(1):17-20. PubMed ID: 12557973 [TBL] [Abstract][Full Text] [Related]
5. Heterogeneity phantoms for visualization of 3D dose distributions by MRI-based polymer gel dosimetry. Watanabe Y; Mooij R; Perera GM; Maryanski MJ Med Phys; 2004 May; 31(5):975-84. PubMed ID: 15191281 [TBL] [Abstract][Full Text] [Related]
6. Dose response evaluation of a low-density normoxic polymer gel dosimeter using MRI. Haraldsson P; Karlsson A; Wieslander E; Gustavsson H; Bäck SA Phys Med Biol; 2006 Feb; 51(4):919-28. PubMed ID: 16467587 [TBL] [Abstract][Full Text] [Related]
7. Use of BANG polymer gel for dose measurements in a 68 MeV proton beam. Heufelder J; Stiefel S; Pfaender M; Lüdemann L; Grebe G; Heese J Med Phys; 2003 Jun; 30(6):1235-40. PubMed ID: 12852548 [TBL] [Abstract][Full Text] [Related]
8. Effects of phantom volume and shape on the accuracy of MRI BANG gel dosimetry using BANG3. MacDougall ND; Miquel ME; Keevil SF Br J Radiol; 2008 Jan; 81(961):46-50. PubMed ID: 17998279 [TBL] [Abstract][Full Text] [Related]
9. Optimization of multiple spin-echo sequences for 3D polymer gel dosimetry. De Deene Y; Baldock C Phys Med Biol; 2002 Sep; 47(17):3117-41. PubMed ID: 12361214 [TBL] [Abstract][Full Text] [Related]
10. Study of the relative dose-response of BANG-3 polymer gel dosimeters in epithermal neutron irradiation. Uusi-Simola J; Savolainen S; Kangasmäki A; Heikkinen S; Perkiö J; Abo Ramadan U; Seppälä T; Karila J; Serén T; Kotiluoto P; Sorvari P; Auterinen I Phys Med Biol; 2003 Sep; 48(17):2895-906. PubMed ID: 14516107 [TBL] [Abstract][Full Text] [Related]
11. Photon beam quality specification by narrow-beam transmission measurements. Nyström H; Karlsson M Phys Med Biol; 1994 Aug; 39(8):1231-45. PubMed ID: 15551564 [TBL] [Abstract][Full Text] [Related]
12. Performance of a commercial optical CT scanner and polymer gel dosimeters for 3-D dose verification. Xu Y; Wuu CS; Maryanski MJ Med Phys; 2004 Nov; 31(11):3024-33. PubMed ID: 15587656 [TBL] [Abstract][Full Text] [Related]
13. Introducing gel dosimetry in a clinical environment: customization of polymer gel composition and magnetic resonance imaging parameters used for 3D dose verifications in radiosurgery and intensity modulated radiotherapy. Crescenti RA; Scheib SG; Schneider U; Gianolini S Med Phys; 2007 Apr; 34(4):1286-97. PubMed ID: 17500460 [TBL] [Abstract][Full Text] [Related]
14. Low-density gel dosimeter for measurement of the electron return effect in an MR-linac. McDonald BA; Lee HJ; Ibbott GS Phys Med Biol; 2019 Oct; 64(20):205016. PubMed ID: 31505483 [TBL] [Abstract][Full Text] [Related]
15. Polymer gel dosimetry using a three-dimensional MRI acquisition technique. Baras P; Seimenis I; Kipouros P; Papagiannis P; Angelopoulos A; Sakelliou L; Pappas E; Baltas D; Karaiskos P; Sandilos P; Vlachos L Med Phys; 2002 Nov; 29(11):2506-16. PubMed ID: 12462715 [TBL] [Abstract][Full Text] [Related]
16. The microdosimetry of low-energy photons in radiotherapy. Reniers B; Verhaegen F Radiat Prot Dosimetry; 2006; 122(1-4):401-3. PubMed ID: 17287204 [TBL] [Abstract][Full Text] [Related]
17. Dose-response curve slope improvement and result reproducibility of ferrous-sulphate-doped gels analysed by NMR imaging. Gambarini G; Arrigoni S; Cantone MC; Molho N; Facchielli L; Sichirollo AE Phys Med Biol; 1994 Apr; 39(4):703-17. PubMed ID: 15552079 [TBL] [Abstract][Full Text] [Related]
18. MAGIC-type polymer gel for three-dimensional dosimetry: intensity-modulated radiation therapy verification. Gustavsson H; Karlsson A; Bäck SA; Olsson LE; Haraldsson P; Engström P; Nyström H Med Phys; 2003 Jun; 30(6):1264-71. PubMed ID: 12852552 [TBL] [Abstract][Full Text] [Related]
19. An automated fast MR-imaging method for localized measurements of dose distributions using NMR-Fricke gel dosimetry. Evaluation of influences on the measurement accuracy. Reichl B; Matthaei D; Richter J; Haase A Strahlenther Onkol; 1996 Jun; 172(6):312-9. PubMed ID: 8677503 [TBL] [Abstract][Full Text] [Related]
20. Evaluation of radiochromic gel dosimetry and polymer gel dosimetry in a clinical dose verification. Vandecasteele J; De Deene Y Phys Med Biol; 2013 Sep; 58(18):6241-62. PubMed ID: 23965800 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]