205 related articles for article (PubMed ID: 12631516)
1. Improving spatial resolution in SPECT with the combination of PSPMT based detector and iterative reconstruction algorithms.
Loudos GK; Nikita KS; Uzunoglu NK; Giokaris ND; Papanicolas CN; Archimandritis SC; Varvarigou D; Maintas D
Comput Med Imaging Graph; 2003; 27(4):307-13. PubMed ID: 12631516
[TBL] [Abstract][Full Text] [Related]
2. Quantification and reduction of the collimator-detector response effect in SPECT by applying a system model during iterative image reconstruction: a simulation study.
Kalantari F; Rajabi H; Saghari M
Nucl Med Commun; 2012 Mar; 33(3):228-38. PubMed ID: 22134173
[TBL] [Abstract][Full Text] [Related]
3. Iterative three-dimensional expectation maximization restoration of single photon emission computed tomography images: application in striatal imaging.
Gantet P; Payoux P; Celler A; Majorel C; Gourion D; Noll D; Esquerré JP
Med Phys; 2006 Jan; 33(1):52-60. PubMed ID: 16485409
[TBL] [Abstract][Full Text] [Related]
4. Characterization of ordered-subsets expectation maximization with 3D post-reconstruction Gauss filtering and comparison with filtered backprojection in 99mTc SPECT.
Brambilla M; Cannillo B; Dominietto M; Leva L; Secco C; Inglese E
Ann Nucl Med; 2005 Apr; 19(2):75-82. PubMed ID: 15909485
[TBL] [Abstract][Full Text] [Related]
5. Fast 3D iterative image reconstruction for SPECT with rotating slat collimators.
Holen RV; Vandenberghe S; Staelens S; De Beenhouwer J; Lemahieu I
Phys Med Biol; 2009 Feb; 54(3):715-29. PubMed ID: 19131666
[TBL] [Abstract][Full Text] [Related]
6. Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT.
Jaszczak RJ; Li J; Wang H; Zalutsky MR; Coleman RE
Phys Med Biol; 1994 Mar; 39(3):425-37. PubMed ID: 15551591
[TBL] [Abstract][Full Text] [Related]
7. ALBIRA: a small animal PET∕SPECT∕CT imaging system.
Sánchez F; Orero A; Soriano A; Correcher C; Conde P; González A; Hernández L; Moliner L; Rodríguez-Alvarez MJ; Vidal LF; Benlloch JM; Chapman SE; Leevy WM
Med Phys; 2013 May; 40(5):051906. PubMed ID: 23635276
[TBL] [Abstract][Full Text] [Related]
8. Correction of photon attenuation and collimator response for a body-contouring SPECT/CT imaging system.
Seo Y; Wong KH; Sun M; Franc BL; Hawkins RA; Hasegawa BH
J Nucl Med; 2005 May; 46(5):868-77. PubMed ID: 15872362
[TBL] [Abstract][Full Text] [Related]
9. A new reconstruction strategy for image improvement in pinhole SPECT.
Zeniya T; Watabe H; Aoi T; Kim KM; Teramoto N; Hayashi T; Sohlberg A; Kudo H; Iida H
Eur J Nucl Med Mol Imaging; 2004 Aug; 31(8):1166-72. PubMed ID: 15029462
[TBL] [Abstract][Full Text] [Related]
10. Performance evaluation of OSEM reconstruction algorithm incorporating three-dimensional distance-dependent resolution compensation for brain SPECT: a simulation study.
Yokoi T; Shinohara H; Onishi H
Ann Nucl Med; 2002 Feb; 16(1):11-8. PubMed ID: 11922203
[TBL] [Abstract][Full Text] [Related]
11. The influence of resolution recovery by using collimator detector response during 3D OSEM image reconstruction on (99m)Tc-ECD brain SPET images.
Kalantari F; Rajabi H; Ay MR; Razavi-Ratki SK; Fard-Esfahani A; Beiki D; Eftekhari M; Fallahi B; Sadeghian L; Emami-Ardekani A
Hell J Nucl Med; 2012; 15(2):92-7. PubMed ID: 22741145
[TBL] [Abstract][Full Text] [Related]
12. Analytic and iterative reconstruction algorithms in SPECT.
Bruyant PP
J Nucl Med; 2002 Oct; 43(10):1343-58. PubMed ID: 12368373
[TBL] [Abstract][Full Text] [Related]
13. Comparison of a noise-weighted filtered backprojection algorithm with the Standard MLEM algorithm for poisson noise.
Zeng GL
J Nucl Med Technol; 2013 Dec; 41(4):283-8. PubMed ID: 24159012
[TBL] [Abstract][Full Text] [Related]
14. Pediatric 99mTc-DMSA SPECT performed by using iterative reconstruction with isotropic resolution recovery: improved image quality and reduced radiopharmaceutical activity.
Sheehy N; Tetrault TA; Zurakowski D; Vija AH; Fahey FH; Treves ST
Radiology; 2009 May; 251(2):511-6. PubMed ID: 19304919
[TBL] [Abstract][Full Text] [Related]
15. Accelerated 3D-OSEM image reconstruction using a Beowulf PC cluster for pinhole SPECT.
Zeniya T; Watabe H; Sohlberg A; Iida H
Ann Nucl Med; 2007 Nov; 21(9):537-43. PubMed ID: 18030588
[TBL] [Abstract][Full Text] [Related]
16. Resolution-recovery-embedded image reconstruction for a high-resolution animal SPECT system.
Zeraatkar N; Sajedi S; Farahani MH; Arabi H; Sarkar S; Ghafarian P; Rahmim A; Ay MR
Phys Med; 2014 Nov; 30(7):774-81. PubMed ID: 24986422
[TBL] [Abstract][Full Text] [Related]
17. Iterative reconstruction of fluorine-18 SPECT using geometric point response correction.
Zeng GL; Gullberg GT; Bai C; Christian PE; Trisjono F; Di Bella EV; Tanner JW; Morgan HT
J Nucl Med; 1998 Jan; 39(1):124-30. PubMed ID: 9443751
[TBL] [Abstract][Full Text] [Related]
18. Is iterative reconstruction an alternative to filtered backprojection in routine processing of dopamine transporter SPECT studies?
Koch W; Hamann C; Welsch J; Pöpperl G; Radau PE; Tatsch K
J Nucl Med; 2005 Nov; 46(11):1804-11. PubMed ID: 16269593
[TBL] [Abstract][Full Text] [Related]
19. Comparison of different types of commercial filtered backprojection and ordered-subset expectation maximization SPECT reconstruction software.
Seret A; Forthomme J
J Nucl Med Technol; 2009 Sep; 37(3):179-87. PubMed ID: 19726808
[TBL] [Abstract][Full Text] [Related]
20. Interest of the ordered subsets expectation maximization (OS-EM) algorithm in pinhole single-photon emission tomography reconstruction: a phantom study.
Vanhove C; Defrise M; Franken PR; Everaert H; Deconinck F; Bossuyt A
Eur J Nucl Med; 2000 Feb; 27(2):140-6. PubMed ID: 10755718
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]