BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

379 related articles for article (PubMed ID: 12632114)

  • 1. Clinical evaluation of a new intracranial pressure monitoring device.
    Stendel R; Heidenreich J; Schilling A; Akhavan-Sigari R; Kurth R; Picht T; Pietilä T; Suess O; Kern C; Meisel J; Brock M
    Acta Neurochir (Wien); 2003 Mar; 145(3):185-93; discussion 193. PubMed ID: 12632114
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Camino intracranial pressure device in clinical practice. Assessment in a 1000 cases.
    Gelabert-González M; Ginesta-Galan V; Sernamito-García R; Allut AG; Bandin-Diéguez J; Rumbo RM
    Acta Neurochir (Wien); 2006 Apr; 148(4):435-41. PubMed ID: 16374566
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Clinical evaluation of a new multiparameter neuromonitoring device: measurement of brain tissue oxygen, brain temperature, and intracranial pressure.
    Huschak G; Hoell T; Hohaus C; Kern C; Minkus Y; Meisel HJ
    J Neurosurg Anesthesiol; 2009 Apr; 21(2):155-60. PubMed ID: 19295395
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Bench test assessment of the new Raumedic Neurovent-P ICP sensor: a technical report by the BrainIT group.
    Citerio G; Piper I; Cormio M; Galli D; Cazzaniga S; Enblad P; Nilsson P; Contant C; Chambers I;
    Acta Neurochir (Wien); 2004 Nov; 146(11):1221-6. PubMed ID: 15338335
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Assessment of zero drift in the Codman intracranial pressure monitor: a study from 2 neurointensive care units.
    Al-Tamimi YZ; Helmy A; Bavetta S; Price SJ
    Neurosurgery; 2009 Jan; 64(1):94-8; discussion 98-9. PubMed ID: 19145157
    [TBL] [Abstract][Full Text] [Related]  

  • 6. The Camino intracranial pressure device in clinical practice: reliability, handling characteristics and complications.
    Münch E; Weigel R; Schmiedek P; Schürer L
    Acta Neurochir (Wien); 1998; 140(11):1113-9; discussion 1119-20. PubMed ID: 9870055
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Risk factors and complications of intracranial pressure monitoring with a fiberoptic device.
    Bekar A; Doğan S; Abaş F; Caner B; Korfali G; Kocaeli H; Yilmazlar S; Korfali E
    J Clin Neurosci; 2009 Feb; 16(2):236-40. PubMed ID: 19071023
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Relevance of ICP and ptiO2 for indication and timing of decompressive craniectomy in patients with malignant brain edema.
    Reithmeier T; Löhr M; Pakos P; Ketter G; Ernestus RI
    Acta Neurochir (Wien); 2005 Sep; 147(9):947-51; discussion 952. PubMed ID: 15912256
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Value of serial CT scanning and intracranial pressure monitoring for detecting new intracranial mass effect in severe head injury patients showing lesions type I-II in the initial CT scan].
    Lobato RD; Alen JF; Perez-Nuñez A; Alday R; Gómez PA; Pascual B; Lagares A; Miranda P; Arrese I; Kaen A
    Neurocirugia (Astur); 2005 Jun; 16(3):217-34. PubMed ID: 16007322
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Continuous EEG-SEP monitoring in severe brain injury.
    Amantini A; Fossi S; Grippo A; Innocenti P; Amadori A; Bucciardini L; Cossu C; Nardini C; Scarpelli S; Roma V; Pinto F
    Neurophysiol Clin; 2009 Apr; 39(2):85-93. PubMed ID: 19467438
    [TBL] [Abstract][Full Text] [Related]  

  • 11. ICP measurement accuracy: the effect of temperature drift. Design of a laboratory test for assessment of ICP transducers.
    Morgalla MH; Mettenleiter H; Katzenberger T
    J Med Eng Technol; 1999; 23(1):10-4. PubMed ID: 10202697
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Intracranial pressure telemetry: first experience of an experimental in vivo study using a new device.
    Orakcioglu B; Beynon C; Kentar MM; Eymann R; Kiefer M; Sakowitz OW
    Acta Neurochir Suppl; 2012; 114():105-10. PubMed ID: 22327673
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [The Spiegelberg device for epidural registration of the ICP].
    Schwarz N; Matuschka H; Meznik A
    Unfallchirurg; 1992 Mar; 95(3):113-7. PubMed ID: 1553562
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Camino intracranial pressure sensor: is it optimal technology? An internal audit with a review of current intracranial pressure monitoring technologies.
    Piper I; Barnes A; Smith D; Dunn L
    Neurosurgery; 2001 Nov; 49(5):1158-64; discussion 1164-5. PubMed ID: 11846910
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Complications of intracranial pressure monitoring in children with head trauma.
    Anderson RC; Kan P; Klimo P; Brockmeyer DL; Walker ML; Kestle JR
    J Neurosurg; 2004 Aug; 101(1 Suppl):53-8. PubMed ID: 16206972
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Preliminary experience with controlled lumbar drainage in medically refractory intracranial hypertension].
    Tömösvári A; Mencser Z; Futó J; Hortobágyi A; Bodosi M; Barzó P
    Orv Hetil; 2005 Jan; 146(4):159-64. PubMed ID: 15751510
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fiberoptic intraparenchymal brain pressure monitoring with the Camino V420 monitor: reflections on our experience in 163 severely head-injured patients.
    Poca MA; Sahuquillo J; Arribas M; Báguena M; Amorós S; Rubio E
    J Neurotrauma; 2002 Apr; 19(4):439-48. PubMed ID: 11990350
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Predictable reduction of intracranial hypertension with hypertonic saline hydroxyethyl starch: a prospective clinical trial in critically ill patients with subarachnoid haemorrhage.
    Bentsen G; Breivik H; Lundar T; Stubhaug A
    Acta Anaesthesiol Scand; 2004 Oct; 48(9):1089-95. PubMed ID: 15352953
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Cardiac uncoupling and heart rate variability are associated with intracranial hypertension and mortality: a study of 145 trauma patients with continuous monitoring.
    Mowery NT; Norris PR; Riordan W; Jenkins JM; Williams AE; Morris JA
    J Trauma; 2008 Sep; 65(3):621-7. PubMed ID: 18784576
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Barbiturate therapy for patients with refractory intracranial hypertension following severe traumatic brain injury: its effects on tissue oxygenation, brain temperature and autoregulation.
    Thorat JD; Wang EC; Lee KK; Seow WT; Ng I
    J Clin Neurosci; 2008 Feb; 15(2):143-8. PubMed ID: 17997313
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]