  • 21. Characterization of uniformity and reproducibility of photoresist nanomasks fabricated by near-field scanning optical nanolithography.
    Kwon S; Jeong Y; Jeong S
    J Nanosci Nanotechnol; 2006 Nov; 6(11):3647-51. PubMed ID: 17252829
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Apertureless near-field scanning Raman microscopy using reflection scattering geometry.
    Sun WX; Shen ZX
    Ultramicroscopy; 2003 Apr; 94(3-4):237-44. PubMed ID: 12524194
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Tip-enhanced near-field Raman spectroscopy with a scanning tunneling microscope and side-illumination optics.
    Yi KJ; He XN; Zhou YS; Xiong W; Lu YF
    Rev Sci Instrum; 2008 Jul; 79(7):073706. PubMed ID: 18681707
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Optical characteristics of atomic force microscopy tips for single-molecule fluorescence applications.
    Gaiduk A; Kühnemuth R; Antonik M; Seidel CA
    Chemphyschem; 2005 May; 6(5):976-83. PubMed ID: 15884085
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Laser fabrication of gold nanoparticle clustered tips for use in apertureless near-field scanning optical microscopy.
    Park KD; Park JS; Park JH; Ahn TK; Lee YH; Jeong MS
    J Nanosci Nanotechnol; 2014 Aug; 14(8):5961-4. PubMed ID: 25936036
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Implementation of a short-tip tapping-mode tuning fork near-field scanning optical microscope.
    Lu NH; Huang CW; Chen CY; Yu CF; Kao TS; Fu YH; Tsai DP
    J Microsc; 2003 Mar; 209(Pt 3):205-8. PubMed ID: 12641763
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Calibrating a tuning fork for use as a scanning probe microscope force sensor.
    Qin Y; Reifenberger R
    Rev Sci Instrum; 2007 Jun; 78(6):063704. PubMed ID: 17614613
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Fabrication and characterization of probes for combined scanning electrochemical/optical microscopy experiments.
    Lee Y; Bard AJ
    Anal Chem; 2002 Aug; 74(15):3626-33. PubMed ID: 12175146
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Design of metal-cladded near-field fiber probes with a dispersive body-of-revolution finite-difference time-domain method.
    Liu L; He S
    Appl Opt; 2005 Jun; 44(17):3429-37. PubMed ID: 16007838
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Improving the lateral resolution of quartz tuning fork-based sensors in liquid by integrating commercial AFM tips into the fiber end.
    Gonzalez L; Martínez-Martín D; Otero J; de Pablo PJ; Puig-Vidal M; Gómez-Herrero J
    Sensors (Basel); 2015 Jan; 15(1):1601-10. PubMed ID: 25594596
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Scanning Near-Field Ellipsometry Microscopy: imaging nanomaterials with resolution below the diffraction limit.
    Tranchida D; Diaz J; Schön P; Schönherr H; Vancso GJ
    Nanoscale; 2011 Jan; 3(1):233-9. PubMed ID: 21042630
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Parallel scanning near-field photolithography: the snomipede.
    ul Haq E; Liu Z; Zhang Y; Ahmad SA; Wong LS; Armes SP; Hobbs JK; Leggett GJ; Micklefield J; Roberts CJ; Weaver JM
    Nano Lett; 2010 Nov; 10(11):4375-80. PubMed ID: 20945880
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Simulation of a metallic SNOM tip illuminated by a parabolic mirror.
    Mihaljevic J; Hafner C; Meixner AJ
    Opt Express; 2013 Nov; 21(22):25926-43. PubMed ID: 24216819
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Shape control of near-field probes using dynamic meniscus etching.
    Haber LH; Schaller RD; Johnson JC; Saykally RJ
    J Microsc; 2004 Apr; 214(Pt 1):27-35. PubMed ID: 15049865
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Transmission and reflection characteristics of metal-coated optical fiber tip pairs.
    Decombe JB; Bryche JF; Motte JF; Chevrier J; Huant S; Fick J
    Appl Opt; 2013 Sep; 52(26):6620-5. PubMed ID: 24085141
    [TBL] [Abstract][Full Text] [Related]  

  • 36. C-V measurements of micron diameter metal-oxide-semiconductor capacitors using a scanning-electron-microscope-based nanoprobe.
    Zheng T; Jia H; Wallace RM; Gnade BE
    Rev Sci Instrum; 2007 Oct; 78(10):104702. PubMed ID: 17979444
    [TBL] [Abstract][Full Text] [Related]  

  • 37. High-resolution constant-height imaging with apertured silicon cantilever probes.
    Dziomba T; Danzebrink HU; Lehrer C; Frey L; Sulzbach T; Ohlsson O
    J Microsc; 2001 Apr; 202(Pt 1):22-7. PubMed ID: 11298864
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Optical field characteristics of nanofocusing by conical metal-coated dielectric probe.
    Tanaka K; Katayama K; Tanaka M
    Opt Express; 2011 Oct; 19(21):21028-37. PubMed ID: 21997111
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Near-field microscopy by elastic light scattering from a tip.
    Keilmann F; Hillenbrand R
    Philos Trans A Math Phys Eng Sci; 2004 Apr; 362(1817):787-805. PubMed ID: 15306494
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Effects of asymmetric surface corrugations on fully metal-coated scanning near field optical microscopy tips.
    Lotito V; Sennhauser U; Hafner C
    Opt Express; 2010 Apr; 18(8):8722-34. PubMed ID: 20588716
    [TBL] [Abstract][Full Text] [Related]  