  • 1. Composite resorbable polymer/hydroxylapatite composite screws for fixation of osteochondral osteotomies.
    Lewandrowski KU; Bondre SP; Shea M; Untch CM; Hayes WC; Hile DD; Wise DL; Trantolo DJ
    Biomed Mater Eng; 2002; 12(4):423-38. PubMed ID: 12652036
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Composite poly(lactide)/hydroxylapatite screws for fixation of osteochondral osteotomies. A morphometric, histologic and radiographic study in sheep.
    Lewandrowski KU; Bondre SP; Shea M; Untch CM; Hayes WC; Hile DD; Wise DL; Trantolo DJ
    J Biomater Sci Polym Ed; 2002; 13(11):1241-58. PubMed ID: 12518802
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Healing of osteochondral osteotomies after fixation with a hydroxyapatite-buffered polylactide. A histomorphometric and radiographic study in rabbits.
    Lewandrowski KU; Bondre SP; Wise DL; Trantolo DJ
    Biomed Mater Eng; 2002; 12(3):259-70. PubMed ID: 12446941
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effect of implant overlap on the mechanical properties of the femur.
    Harris T; Ruth JT; Szivek J; Haywood B
    J Trauma; 2003 May; 54(5):930-5. PubMed ID: 12777906
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Biomechanical comparison of two side plate fixation techniques in an unstable intertrochanteric osteotomy model: Sliding Hip Screw and Percutaneous Compression Plate.
    Krischak GD; Augat P; Beck A; Arand M; Baier B; Blakytny R; Gebhard F; Claes L
    Clin Biomech (Bristol, Avon); 2007 Dec; 22(10):1112-8. PubMed ID: 17900766
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Prospective evaluation of patellar tendon graft fixation in anterior cruciate ligament reconstruction comparing composite bioabsorbable and allograft interference screws.
    Tecklenburg K; Burkart P; Hoser C; Rieger M; Fink C
    Arthroscopy; 2006 Sep; 22(9):993-9. PubMed ID: 16952730
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The tissue-implant interface during degradation of absorbable polyglycolide fracture fixation screws in the rabbit femur.
    Böstman OM; Päivärinta U; Partio E; Manninen M; Vasenius J; Majola A; Rokkanen P
    Clin Orthop Relat Res; 1992 Dec; (285):263-72. PubMed ID: 1332836
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical analysis of distal femur fracture fixation: fixed-angle screw-plate construct versus condylar blade plate.
    Higgins TF; Pittman G; Hines J; Bachus KN
    J Orthop Trauma; 2007 Jan; 21(1):43-6. PubMed ID: 17211268
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Computerized analysis of resorbable polymer plates and screws for the rigid fixation of mandibular angle fractures.
    Cox T; Kohn MW; Impelluso T
    J Oral Maxillofac Surg; 2003 Apr; 61(4):481-7; discussion 487-8. PubMed ID: 12684967
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Coronal fractures of the distal femoral condyle: a biomechanical evaluation of four internal fixation constructs.
    Hak DJ; Nguyen J; Curtiss S; Hazelwood S
    Injury; 2005 Sep; 36(9):1103-6. PubMed ID: 15982653
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Polyaxial locking plate fixation in distal femur fractures: a biomechanical comparison.
    Wilkens KJ; Curtiss S; Lee MA
    J Orthop Trauma; 2008 Oct; 22(9):624-8. PubMed ID: 18827592
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Increasing nail-cortical contact to increase fixation stability and decrease implant strain in antegrade locked nailing of distal femoral fractures: a biomechanical study.
    Huang SC; Lin CC; Lin J
    J Trauma; 2009 Feb; 66(2):436-42. PubMed ID: 19065112
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pedicle screw surface coatings improve fixation in nonfusion spinal constructs.
    Upasani VV; Farnsworth CL; Tomlinson T; Chambers RC; Tsutsui S; Slivka MA; Mahar AT; Newton PO
    Spine (Phila Pa 1976); 2009 Feb; 34(4):335-43. PubMed ID: 19182704
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Fixation of HA-coated unicortical locking screws in a sheep gap model: a comparative biomechanical study.
    Moroni A; Pegreffi F; Hoang-Kim A; Tesei F; Giannini S; Wippermann B
    J Orthop Trauma; 2008 Jan; 22(1):37-42. PubMed ID: 18176163
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Fixation of the femoral condyles: a mechanical comparison of small and large fragment screw fixation.
    Khalafi A; Hazelwood S; Curtiss S; Wolinsky P
    J Trauma; 2008 Mar; 64(3):740-4. PubMed ID: 18332817
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Primary stability of hamstring graft fixation with biodegradable suspension versus interference screws.
    Weimann A; Rodieck M; Zantop T; Hassenpflug J; Petersen W
    Arthroscopy; 2005 Mar; 21(3):266-74. PubMed ID: 15756178
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Repair of an intercalated long bone defect with a synthetic biodegradable bone-inducing implant.
    Yoneda M; Terai H; Imai Y; Okada T; Nozaki K; Inoue H; Miyamoto S; Takaoka K
    Biomaterials; 2005 Sep; 26(25):5145-52. PubMed ID: 15792541
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Development of a multi-component fiber-reinforced composite implant for load-sharing conditions.
    Zhao DS; Moritz N; Laurila P; Mattila R; Lassila LV; Strandberg N; Mäntylä T; Vallittu PK; Aro HT
    Med Eng Phys; 2009 May; 31(4):461-9. PubMed ID: 19109047
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Fixation of osteotomies using bioabsorbable screws in the canine femur.
    An YH; Friedman RJ; Powers DL; Draughn RA; Latour RA
    Clin Orthop Relat Res; 1998 Oct; (355):300-11. PubMed ID: 9917616
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Resorbable fillers reduce stress risers from empty screw holes.
    Alford JW; Bradley MP; Fadale PD; Crisco JJ; Moore DC; Ehrlich MG
    J Trauma; 2007 Sep; 63(3):647-54. PubMed ID: 18073615
    [TBL] [Abstract][Full Text] [Related]  