1. Effects of hemolysis on serum chemistry analytes in ratites. Andreasen CB; Andreasen JR; Thomas JS Vet Clin Pathol; 1997; 26(4):165-171. PubMed ID: 12658578 [TBL] [Abstract][Full Text] [Related]
2. The effects of haemolysis on serum chemistry measurements in poultry. Andreasen JR; Andreasen CB; Sonn AB; Robeson DC Avian Pathol; 1996 Sep; 25(3):519-36. PubMed ID: 18645876 [TBL] [Abstract][Full Text] [Related]
3. Assessing the influence of true hemolysis occurring in patient samples on emergency clinical biochemistry tests results using the VITROS Liu S; Li J; Ning L; Wu D; Wei D Biomed Rep; 2021 Nov; 15(5):91. PubMed ID: 34631046 [TBL] [Abstract][Full Text] [Related]
4. Influence of hemolysis on clinical chemistry parameters determined with Beckman Coulter tests - detection of clinically significant interference. Perović A; Dolčić M Scand J Clin Lab Invest; 2019 May; 79(3):154-159. PubMed ID: 30767593 [TBL] [Abstract][Full Text] [Related]
6. Method comparison and generation of plasma biochemistry RIs for the White rhinoceros on a point-of-care and wet chemistry analyzer. Hooijberg EH; Steenkamp G; Buss P; Goddard A Vet Clin Pathol; 2017 Jun; 46(2):287-298. PubMed ID: 28419525 [TBL] [Abstract][Full Text] [Related]
7. Effects of the hemolytic index on the test results of a dry chemistry analyzer and a verification of the hemolytic interference threshold. Yang Q; Huang S; Han R; Lin B; Liu Q; Duan X; Ma Z; Zhang H; Shou H; Zhang S Ann Palliat Med; 2022 Apr; 11(4):1381-1390. PubMed ID: 35523746 [TBL] [Abstract][Full Text] [Related]
8. Effects of hemolysis interferences on routine biochemistry parameters. Koseoglu M; Hur A; Atay A; Cuhadar S Biochem Med (Zagreb); 2011; 21(1):79-85. PubMed ID: 22141211 [TBL] [Abstract][Full Text] [Related]
9. PAIRED BIOCHEMICAL ANALYSIS OF PIGMENTED PLASMA SAMPLES FROM ZOO-KEPT AMERICAN FLAMINGOS ( Gancz AY; Eshar D; Beaufrère H J Zoo Wildl Med; 2019 Sep; 50(3):619-626. PubMed ID: 33517631 [TBL] [Abstract][Full Text] [Related]
10. Comparison of two dry chemistry analyzers and a wet chemistry analyzer using canine serum. Lanevschi A; Kramer JW Vet Clin Pathol; 1996; 25(1):10-13. PubMed ID: 12660981 [TBL] [Abstract][Full Text] [Related]
11. Hemolysis indexes for biochemical tests and immunoassays on Roche analyzers: determination of allowable interference limits according to different calculation methods. Monneret D; Mestari F; Atlan G; Corlouer C; Ramani Z; Jaffre J; Dever S; Fressart V; Alkouri R; Lamari F; Devilliers C; Imbert-Bismut F; Bonnefont-Rousselot D Scand J Clin Lab Invest; 2015 Apr; 75(2):162-9. PubMed ID: 25608598 [TBL] [Abstract][Full Text] [Related]
12. Effects of hemolysis on plasma electrolyte and chemistry values in the common green iguana (Iguana iguana). Benson KG; Paul-Murphy J; MacWilliams P J Zoo Wildl Med; 1999 Sep; 30(3):413-5. PubMed ID: 10572866 [TBL] [Abstract][Full Text] [Related]
13. Hemolysis as a factor in clinical chemistry and hematology of the dog. O'Neill SL; Feldman BF Vet Clin Pathol; 1989; 18(3):58-68. PubMed ID: 15156513 [TBL] [Abstract][Full Text] [Related]
14. Evaluation of Sensitive Analytes to Hemolysis Interference on an Automated Chemistry Analyzer. Marakankadavu Parambu M; Bush V J Appl Lab Med; 2024 May; 9(3):558-564. PubMed ID: 38300631 [TBL] [Abstract][Full Text] [Related]
15. Comparison of avian biochemical test results with Abaxis VetScan and Hitachi 911 analyzers. Greenacre CB; Flatland B; Souza MJ; Fry MM J Avian Med Surg; 2008 Dec; 22(4):291-9. PubMed ID: 19216256 [TBL] [Abstract][Full Text] [Related]
16. [Hemolysis influence on twenty-two biochemical parameters measurement]. Ali D; Sacchetto E; Dumontet E; Le Carrer D; Orsonneau JL; Delaroche O; Bigot-Corbel E Ann Biol Clin (Paris); 2014; 72(3):297-311. PubMed ID: 24876141 [TBL] [Abstract][Full Text] [Related]
17. The degree of acceptability of swine blood values at increasing levels of hemolysis evaluated through visual inspection versus automated quantification. Di Martino G; Stefani AL; Lippi G; Gagliazzo L; McCormick W; Gabai G; Bonfanti L J Vet Diagn Invest; 2015 May; 27(3):306-12. PubMed ID: 26038480 [TBL] [Abstract][Full Text] [Related]
18. Relationship between separation time of plasma from heparinized whole blood on plasma biochemical analytes of loggerhead sea turtles (Caretta caretta). Eisenhawer E; Courtney CH; Raskin RE; Jacobson E J Zoo Wildl Med; 2008 Jun; 39(2):208-15. PubMed ID: 18634211 [TBL] [Abstract][Full Text] [Related]
19. Icteric human samples: Icterus index and method of estimating an interference-free value for 16 biochemical analyses. Nicolay A; Lorec AM; Gomez G; Portugal H J Clin Lab Anal; 2018 Feb; 32(2):. PubMed ID: 28397988 [TBL] [Abstract][Full Text] [Related]