These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

128 related articles for article (PubMed ID: 12662227)

  • 1. Retrospective study of the utility of nuclear scintigraphic-labelled red cell scanning for lower gastrointestinal bleeding.
    Levy R; Barto W; Gani J
    ANZ J Surg; 2003 Apr; 73(4):205-9. PubMed ID: 12662227
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accurate localization and surgical management of active lower gastrointestinal hemorrhage with technetium-labeled erythrocyte scintigraphy.
    Suzman MS; Talmor M; Jennis R; Binkert B; Barie PS
    Ann Surg; 1996 Jul; 224(1):29-36. PubMed ID: 8678614
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Value of scintigraphic localization of obscure gastrointestinal bleeding.
    Ohri SK; Desa LA; Lee H; Patel T; Jackson J; Lavender JP; Spencer J
    J R Coll Surg Edinb; 1992 Oct; 37(5):328-32. PubMed ID: 1282552
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The clinical utility of nuclear medicine imaging for the detection of occult gastrointestinal haemorrhage.
    Howarth DM; Tang K; Lees W
    Nucl Med Commun; 2002 Jun; 23(6):591-4. PubMed ID: 12029216
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Localization of lower gastrointestinal bleeding using in vivo technetium-99m-labelled red blood cell scintigraphy.
    Nicholson ML; Neoptolemos JP; Sharp JF; Watkin EM; Fossard DP
    Br J Surg; 1989 Apr; 76(4):358-61. PubMed ID: 2541861
    [TBL] [Abstract][Full Text] [Related]  

  • 6. [Improved detection of gastrointestinal bleeding sites with 99mTc market autologous erythrocytes and continuous dynamic scintigraphy with cine-mode display].
    Meller J; Schönborn E; Conrad M; Horstmann O; Raddatz D; Becker W
    Chirurg; 2000 Mar; 71(3):292-9. PubMed ID: 10789046
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Technetium-labelled red blood cell scintigraphy: is it useful in acute lower gastrointestinal bleeding?
    Rantis PC; Harford FJ; Wagner RH; Henkin RE
    Int J Colorectal Dis; 1995; 10(4):210-5. PubMed ID: 8568406
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of technetium-labeled red blood cell scintigraphy in the detection and management of gastrointestinal hemorrhage.
    Voeller GR; Bunch G; Britt LG
    Surgery; 1991 Oct; 110(4):799-804. PubMed ID: 1925969
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The yield of bleeding scans in acute lower gastrointestinal hemorrhage.
    Olds GD; Cooper GS; Chak A; Sivak MV; Chitale AA; Wong RC
    J Clin Gastroenterol; 2005 Apr; 39(4):273-7. PubMed ID: 15758618
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Localization of obscure gastrointestinal bleeding by technetium 99m-labeled red blood cell scintigraphy.
    Wang CS; Tzen KY; Huang MJ; Wang JY; Chen MF
    J Formos Med Assoc; 1992 Jan; 91(1):63-8. PubMed ID: 1352337
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Does hemodynamic instability predict positive technetium-labeled red blood cell scintigraphy in patients with acute lower gastrointestinal bleeding? A review of 50 patients.
    Feingold DL; Caliendo FJ; Chinn BT; Notaro JR; Oliver GC; Salvati EP; Wilkins KB; Eisenstat TE
    Dis Colon Rectum; 2005 May; 48(5):1001-4. PubMed ID: 15793644
    [TBL] [Abstract][Full Text] [Related]  

  • 12. 99mTechnetium-labelled red blood cell scintigraphy as an alternative to angiography in the investigation of gastrointestinal bleeding: clinical experience in a district general hospital.
    Bearn P; Persad R; Wilson N; Flanagan J; Williams T
    Ann R Coll Surg Engl; 1992 May; 74(3):192-9. PubMed ID: 1319696
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The accuracy of technetium-99m-labeled red cell scintigraphy in localizing gastrointestinal bleeding.
    Dusold R; Burke K; Carpentier W; Dyck WP
    Am J Gastroenterol; 1994 Mar; 89(3):345-8. PubMed ID: 8122642
    [TBL] [Abstract][Full Text] [Related]  

  • 14. [Scintigraphy of bleeding. The diagnostic value based on a 10-year period].
    Linnet J; Abrahamsen J
    Ugeskr Laeger; 1995 Sep; 157(39):5373-7. PubMed ID: 7483048
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Negative endoscopy and MSCT findings in patients with acute lower gastrointestinal hemorrhage. Value of (99m)Tc erythrocyte scintigraphy].
    Diehl SJ; Ko HS; Dominguez E; Kaare Tesdal I; Kähler G; Böhm C; Düber C
    Radiologe; 2007 Jan; 47(1):64-70. PubMed ID: 17096110
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Single-photon emission computed tomography enhanced Tc-99m-pertechnetate disodium-labelled red blood cell scintigraphy in the localization of small intestine bleeding: a single-centre twelve-year study.
    Dolezal J; Vizda J; Kopacova M
    Digestion; 2011; 84(3):207-11. PubMed ID: 21757912
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Localization of lower gastrointestinal hemorrhage. Experience with red blood cells labeled in vitro with technetium Tc 99m.
    Orecchia PM; Hensley EK; McDonald PT; Lull RJ
    Arch Surg; 1985 May; 120(5):621-4. PubMed ID: 3872653
    [TBL] [Abstract][Full Text] [Related]  

  • 18. The role of labelled red blood cell scintigraphy in the detection of acute gastrointestinal bleeding.
    Khan O; Singh P; Archibald A; Maharaj P
    West Indian Med J; 2000 Dec; 49(4):298-301. PubMed ID: 11211539
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The role of tagged red blood cell imaging in the localization of gastrointestinal bleeding.
    Bentley DE; Richardson JD
    Arch Surg; 1991 Jul; 126(7):821-4. PubMed ID: 1854241
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Red blood cell scintigraphy in children with acute massive gastrointestinal bleeding.
    Lee J; Lai MW; Chen CC; Chen SY; Chao HC; Chan SC; Kong MS
    Pediatr Int; 2008 Apr; 50(2):199-203. PubMed ID: 18353059
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.