157 related articles for article (PubMed ID: 12663175)
1. Sampling and analysis of gas-phase methylmercury in ambient air.
Lee YH; Wängberg I; Munthe J
Sci Total Environ; 2003 Mar; 304(1-3):107-13. PubMed ID: 12663175
[TBL] [Abstract][Full Text] [Related]
2. Development and application of a sensitive method to determine concentrations of acrolein and other carbonyls in ambient air.
Cahill TM; Charles MJ; Seaman VY;
Res Rep Health Eff Inst; 2010 May; (149):3-46. PubMed ID: 20608023
[TBL] [Abstract][Full Text] [Related]
3. Field evaluation of nanofilm detectors for measuring acidic particles in indoor and outdoor air.
Cohen BS; Heikkinen MS; Hazi Y; Gao H; Peters P; Lippmann M
Res Rep Health Eff Inst; 2004 Sep; (121):1-35; discussion 37-46. PubMed ID: 15553489
[TBL] [Abstract][Full Text] [Related]
4. Tandem capillary column gas chromatography-mass spectrometric determination of the organophosphonate nerve agent surrogate dimethyl methylphosphonate in gaseous phase.
McDaniel LN; Romero NA; Boyd J; Coimbatore G; Cobb GP
Talanta; 2010 Jun; 81(4-5):1568-71. PubMed ID: 20441940
[TBL] [Abstract][Full Text] [Related]
5. Improved accuracy in the determination of polycyclic aromatic hydrocarbons in air using 24 h sampling on a mixed bed followed by thermal desorption capillary gas chromatography-mass spectrometry.
Wauters E; Van Caeter P; Desmet G; David F; Devos C; Sandra P
J Chromatogr A; 2008 May; 1190(1-2):286-93. PubMed ID: 18359031
[TBL] [Abstract][Full Text] [Related]
6. Optimization of headspace solid-phase microextraction gas chromatography-atomic emission detection analysis of monomethylmercury.
Geerdink RB; Breidenbach R; Epema OJ
J Chromatogr A; 2007 Dec; 1174(1-2):7-12. PubMed ID: 17904566
[TBL] [Abstract][Full Text] [Related]
7. A sensitive method for the quantification of acrolein and other volatile carbonyls in ambient air.
Seaman VY; Charles MJ; Cahill TM
Anal Chem; 2006 Apr; 78(7):2405-12. PubMed ID: 16579627
[TBL] [Abstract][Full Text] [Related]
8. Analysis of low concentration reduced sulfur compounds (RSCs) in air: storage issues and measurement by gas chromatography with sulfur chemiluminescence detection.
Khan MA; Whelan ME; Rhew RC
Talanta; 2012 Jan; 88():581-6. PubMed ID: 22265544
[TBL] [Abstract][Full Text] [Related]
9. Size-separated sampling and analysis of isocyanates in workplace aerosols. Part I. Denuder--cascade impactor sampler.
Dahlin J; Spanne M; Karlsson D; Dalene M; Skarping G
Ann Occup Hyg; 2008 Jul; 52(5):361-74. PubMed ID: 18458354
[TBL] [Abstract][Full Text] [Related]
10. A kinetic study on the abiotic methylation of divalent mercury in the aqueous phase.
Gårdfeldt K; Munthe J; Strömberg D; Lindqvist O
Sci Total Environ; 2003 Mar; 304(1-3):127-36. PubMed ID: 12663177
[TBL] [Abstract][Full Text] [Related]
11. Simultaneous sampling and analysis for vapor mercury in ambient air using needle trap coupled with gas chromatography-mass spectrometry.
Cai J; Ouyang G; Gong Y; Pawliszyn J
J Chromatogr A; 2008 Dec; 1213(1):19-24. PubMed ID: 18829037
[TBL] [Abstract][Full Text] [Related]
12. Measurements of dissolved methylmercury in natural waters using diffusive gradients in thin film (DGT).
Clarisse O; Hintelmann H
J Environ Monit; 2006 Dec; 8(12):1242-7. PubMed ID: 17133281
[TBL] [Abstract][Full Text] [Related]
13. Improvements of reliability for methylmercury determination in environmental samples.
Yang DY; Truong HY; Chen YW; Belzile N
Anal Chim Acta; 2009 Feb; 633(2):157-64. PubMed ID: 19166718
[TBL] [Abstract][Full Text] [Related]
14. Determination of decamethylcyclopentasiloxane in air using commercial solid phase extraction cartridges.
Kierkegaard A; McLachlan MS
J Chromatogr A; 2010 May; 1217(21):3557-60. PubMed ID: 20399438
[TBL] [Abstract][Full Text] [Related]
15. Simultaneous determination of airborne carbonyls and aromatic hydrocarbons using mixed sorbent collection and thermal desorption-gas chromatography/mass spectrometric analysis.
Chien YC; Yin KG
J Environ Monit; 2009 May; 11(5):1013-9. PubMed ID: 19436859
[TBL] [Abstract][Full Text] [Related]
16. Development of a miniaturized diffusive sampler for true breathing-zone sampling and thermal desorption gas chromatographic analysis.
Lindahl R; Levin JO; Sundgren M
J Environ Monit; 2009 Jul; 11(7):1340-4. PubMed ID: 20449222
[TBL] [Abstract][Full Text] [Related]
17. Methylmercury determination in biota by solid-phase microextraction matrix effect evaluation.
Carrasco L; Díez S; Bayona JM
J Chromatogr A; 2007 Dec; 1174(1-2):2-6. PubMed ID: 17936289
[TBL] [Abstract][Full Text] [Related]
18. [Collecting of trichloroaniline in the air by micropore filter membrane and determination by gas chromatography].
Wang X; Sheng J; Ye M; Huang X
Wei Sheng Yan Jiu; 2001 Jan; 30(1):20-2. PubMed ID: 11255754
[TBL] [Abstract][Full Text] [Related]
19. Evaluation of a fluorometric method for measuring low concentrations of ammonia in ambient air.
Groves WA; Agarwal D; Chandra MJ; Reynolds SJ
J Environ Monit; 2005 Feb; 7(2):163-8. PubMed ID: 15690098
[TBL] [Abstract][Full Text] [Related]
20. Sampling, storage, and analysis of C2-C7 non-methane hydrocarbons from the US National Oceanic and Atmospheric Administration Cooperative Air Sampling Network glass flasks.
Pollmann J; Helmig D; Hueber J; Plass-Dülmer C; Tans P
J Chromatogr A; 2008 Apr; 1188(2):75-87. PubMed ID: 18355832
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]