161 related articles for article (PubMed ID: 12666776)
1. Relative movements between Kinemax Plus tibial inserts and the tibial base-plates.
Ash HE; Scholes SC; Parkin R; Unsworth A
Proc Inst Mech Eng H; 2003; 217(2):99-104. PubMed ID: 12666776
[TBL] [Abstract][Full Text] [Related]
2. Long-term results for Kinemax and Kinematic knee bearings on a six-station knee wear simulator.
Ash HE; Burgess IC; Unsworth A
Proc Inst Mech Eng H; 2000; 214(5):437-47. PubMed ID: 11109851
[TBL] [Abstract][Full Text] [Related]
3. The influence of design, materials and kinematics on the in vitro wear of total knee replacements.
McEwen HM; Barnett PI; Bell CJ; Farrar R; Auger DD; Stone MH; Fisher J
J Biomech; 2005 Feb; 38(2):357-65. PubMed ID: 15598464
[TBL] [Abstract][Full Text] [Related]
4. Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics.
Benson LC; DesJardins JD; LaBerge M
J Biomed Mater Res; 2001; 58(5):496-504. PubMed ID: 11505423
[TBL] [Abstract][Full Text] [Related]
5. Backside wear of modular ultra-high molecular weight polyethylene tibial inserts.
Conditt MA; Ismaily SK; Alexander JW; Noble PC
J Bone Joint Surg Am; 2004 May; 86(5):1031-7. PubMed ID: 15118049
[TBL] [Abstract][Full Text] [Related]
6. A new method of in vitro wear assessment of the UHMWPE tibial insert in total knee replacement.
Affatato S; Cristofolini L; Leardini W; Erani P; Zavalloni M; Tigani D; Viceconti M
Artif Organs; 2008 Dec; 32(12):942-8. PubMed ID: 19133022
[TBL] [Abstract][Full Text] [Related]
7. Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator.
Benson LC; DesJardins JD; Harman MK; LaBerge M
Proc Inst Mech Eng H; 2002; 216(6):409-18. PubMed ID: 12502005
[TBL] [Abstract][Full Text] [Related]
8. Development of a six station knee wear simulator and preliminary wear results.
Burgess IC; Kolar M; Cunningham JL; Unsworth A
Proc Inst Mech Eng H; 1997; 211(1):37-47. PubMed ID: 9141889
[TBL] [Abstract][Full Text] [Related]
9. Metrology to quantify wear and creep of polyethylene tibial knee inserts.
Muratoglu OK; Perinchief RS; Bragdon CR; O'Connor DO; Konrad R; Harris WH
Clin Orthop Relat Res; 2003 May; (410):155-64. PubMed ID: 12771826
[TBL] [Abstract][Full Text] [Related]
10. Analysis of wear asymmetry in a series of 94 retrieved polyethylene tibial bearings.
Currier JH; Bill MA; Mayor MB
J Biomech; 2005 Feb; 38(2):367-75. PubMed ID: 15598465
[TBL] [Abstract][Full Text] [Related]
11. Compliant layer bearings in artificial joints. Part 2: simulator and fatigue testing to assess the durability of the interface between an elastomeric layer and a rigid substrate.
Jones E; Scholes SC; Burgess IC; Ash HE; Unsworth A
Proc Inst Mech Eng H; 2009 Jan; 223(1):1-12. PubMed ID: 19239063
[TBL] [Abstract][Full Text] [Related]
12. Wear of contemporary total knee replacements--a knee simulator study of six current designs.
Utzschneider S; Harrasser N; Schroeder C; Mazoochian F; Jansson V
Clin Biomech (Bristol, Avon); 2009 Aug; 24(7):583-8. PubMed ID: 19450910
[TBL] [Abstract][Full Text] [Related]
13. Micro-wear patterns on UHMWPE tibial inserts in total knee joint simulation.
Tamura J; Clarke IC; Kawanabe K; Akagi M; Good VD; Williams PA; Masaoka T; Schroeder D; Oonishi H
J Biomed Mater Res; 2002 Aug; 61(2):218-25. PubMed ID: 12007202
[TBL] [Abstract][Full Text] [Related]
14. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty.
Wasielewski RC; Galante JO; Leighty RM; Natarajan RN; Rosenberg AG
Clin Orthop Relat Res; 1994 Feb; (299):31-43. PubMed ID: 8119035
[TBL] [Abstract][Full Text] [Related]
15. Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: a knee simulator study.
Kretzer JP; Jakubowitz E; Reinders J; Lietz E; Moradi B; Hofmann K; Sonntag R
Acta Biomater; 2011 Feb; 7(2):710-5. PubMed ID: 20883831
[TBL] [Abstract][Full Text] [Related]
16. The effect of valgus/varus malalignment on load distribution in total knee replacements.
Werner FW; Ayers DC; Maletsky LP; Rullkoetter PJ
J Biomech; 2005 Feb; 38(2):349-55. PubMed ID: 15598463
[TBL] [Abstract][Full Text] [Related]
17. Effect of head size on wear properties of metal-on-metal bearings of hip prostheses, and comparison with wear properties of metal-on-polyethylene bearings using hip simulator.
Okazaki Y
J Mech Behav Biomed Mater; 2014 Mar; 31():152-63. PubMed ID: 24290355
[TBL] [Abstract][Full Text] [Related]
18. Third-body abrasive wear of tibial polyethylene inserts combined with metallic and ceramic femoral components in a knee simulator study.
Zietz C; Bergschmidt P; Lange R; Mittelmeier W; Bader R
Int J Artif Organs; 2013 Jan; 36(1):47-55. PubMed ID: 23335379
[TBL] [Abstract][Full Text] [Related]
19. Crosslink Density Is Reduced and Oxidation Is Increased in Retrieved Highly Crosslinked Polyethylene TKA Tibial Inserts.
Liu T; Esposito CI; Burket JC; Wright TM
Clin Orthop Relat Res; 2017 Jan; 475(1):128-136. PubMed ID: 27084716
[TBL] [Abstract][Full Text] [Related]
20. Elasto-plastic contact analysis of an ultra-high molecular weight polyethylene tibial component based on geometrical measurement from a retrieved knee prosthesis.
Cho CH; Murakami T; Sawae Y; Sakai N; Miura H; Kawano T; Iwamoto Y
Proc Inst Mech Eng H; 2004; 218(4):251-9. PubMed ID: 15376727
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]