BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

161 related articles for article (PubMed ID: 12666776)

  • 1. Relative movements between Kinemax Plus tibial inserts and the tibial base-plates.
    Ash HE; Scholes SC; Parkin R; Unsworth A
    Proc Inst Mech Eng H; 2003; 217(2):99-104. PubMed ID: 12666776
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Long-term results for Kinemax and Kinematic knee bearings on a six-station knee wear simulator.
    Ash HE; Burgess IC; Unsworth A
    Proc Inst Mech Eng H; 2000; 214(5):437-47. PubMed ID: 11109851
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The influence of design, materials and kinematics on the in vitro wear of total knee replacements.
    McEwen HM; Barnett PI; Bell CJ; Farrar R; Auger DD; Stone MH; Fisher J
    J Biomech; 2005 Feb; 38(2):357-65. PubMed ID: 15598464
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematics.
    Benson LC; DesJardins JD; LaBerge M
    J Biomed Mater Res; 2001; 58(5):496-504. PubMed ID: 11505423
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Backside wear of modular ultra-high molecular weight polyethylene tibial inserts.
    Conditt MA; Ismaily SK; Alexander JW; Noble PC
    J Bone Joint Surg Am; 2004 May; 86(5):1031-7. PubMed ID: 15118049
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A new method of in vitro wear assessment of the UHMWPE tibial insert in total knee replacement.
    Affatato S; Cristofolini L; Leardini W; Erani P; Zavalloni M; Tigani D; Viceconti M
    Artif Organs; 2008 Dec; 32(12):942-8. PubMed ID: 19133022
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulator.
    Benson LC; DesJardins JD; Harman MK; LaBerge M
    Proc Inst Mech Eng H; 2002; 216(6):409-18. PubMed ID: 12502005
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Development of a six station knee wear simulator and preliminary wear results.
    Burgess IC; Kolar M; Cunningham JL; Unsworth A
    Proc Inst Mech Eng H; 1997; 211(1):37-47. PubMed ID: 9141889
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Metrology to quantify wear and creep of polyethylene tibial knee inserts.
    Muratoglu OK; Perinchief RS; Bragdon CR; O'Connor DO; Konrad R; Harris WH
    Clin Orthop Relat Res; 2003 May; (410):155-64. PubMed ID: 12771826
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Analysis of wear asymmetry in a series of 94 retrieved polyethylene tibial bearings.
    Currier JH; Bill MA; Mayor MB
    J Biomech; 2005 Feb; 38(2):367-75. PubMed ID: 15598465
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Compliant layer bearings in artificial joints. Part 2: simulator and fatigue testing to assess the durability of the interface between an elastomeric layer and a rigid substrate.
    Jones E; Scholes SC; Burgess IC; Ash HE; Unsworth A
    Proc Inst Mech Eng H; 2009 Jan; 223(1):1-12. PubMed ID: 19239063
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Wear of contemporary total knee replacements--a knee simulator study of six current designs.
    Utzschneider S; Harrasser N; Schroeder C; Mazoochian F; Jansson V
    Clin Biomech (Bristol, Avon); 2009 Aug; 24(7):583-8. PubMed ID: 19450910
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Micro-wear patterns on UHMWPE tibial inserts in total knee joint simulation.
    Tamura J; Clarke IC; Kawanabe K; Akagi M; Good VD; Williams PA; Masaoka T; Schroeder D; Oonishi H
    J Biomed Mater Res; 2002 Aug; 61(2):218-25. PubMed ID: 12007202
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Wear patterns on retrieved polyethylene tibial inserts and their relationship to technical considerations during total knee arthroplasty.
    Wasielewski RC; Galante JO; Leighty RM; Natarajan RN; Rosenberg AG
    Clin Orthop Relat Res; 1994 Feb; (299):31-43. PubMed ID: 8119035
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Wear analysis of unicondylar mobile bearing and fixed bearing knee systems: a knee simulator study.
    Kretzer JP; Jakubowitz E; Reinders J; Lietz E; Moradi B; Hofmann K; Sonntag R
    Acta Biomater; 2011 Feb; 7(2):710-5. PubMed ID: 20883831
    [TBL] [Abstract][Full Text] [Related]  

  • 16. The effect of valgus/varus malalignment on load distribution in total knee replacements.
    Werner FW; Ayers DC; Maletsky LP; Rullkoetter PJ
    J Biomech; 2005 Feb; 38(2):349-55. PubMed ID: 15598463
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of head size on wear properties of metal-on-metal bearings of hip prostheses, and comparison with wear properties of metal-on-polyethylene bearings using hip simulator.
    Okazaki Y
    J Mech Behav Biomed Mater; 2014 Mar; 31():152-63. PubMed ID: 24290355
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Third-body abrasive wear of tibial polyethylene inserts combined with metallic and ceramic femoral components in a knee simulator study.
    Zietz C; Bergschmidt P; Lange R; Mittelmeier W; Bader R
    Int J Artif Organs; 2013 Jan; 36(1):47-55. PubMed ID: 23335379
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Crosslink Density Is Reduced and Oxidation Is Increased in Retrieved Highly Crosslinked Polyethylene TKA Tibial Inserts.
    Liu T; Esposito CI; Burket JC; Wright TM
    Clin Orthop Relat Res; 2017 Jan; 475(1):128-136. PubMed ID: 27084716
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Elasto-plastic contact analysis of an ultra-high molecular weight polyethylene tibial component based on geometrical measurement from a retrieved knee prosthesis.
    Cho CH; Murakami T; Sawae Y; Sakai N; Miura H; Kawano T; Iwamoto Y
    Proc Inst Mech Eng H; 2004; 218(4):251-9. PubMed ID: 15376727
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.