These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

297 related articles for article (PubMed ID: 12674241)

  • 1. Dosimetric characteristics of a linear array of gamma or beta-emitting seeds in intravascular irradiation: Monte Carlo studies for the AAPM TG-43/60 formalism.
    Ye SJ; Parsai EI; Feldmeier JJ
    Med Phys; 2003 Mar; 30(3):403-14. PubMed ID: 12674241
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Monte Carlo calculated TG-43 dosimetry parameters for the SeedLink 125Iodine brachytherapy system.
    Medich DC; Munro JJ
    Med Phys; 2003 Sep; 30(9):2503-8. PubMed ID: 14528972
    [TBL] [Abstract][Full Text] [Related]  

  • 3. AAPM TG-43 formalism for brachytherapy dose calculation of a 137Cs tube source.
    Zhang P; Beddar AS; Sibata CH
    Med Phys; 2004 Apr; 31(4):755-9. PubMed ID: 15124992
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Monte Carlo dose characterization of a new 90Sr/90Y source with balloon for intravascular brachytherapy.
    Wang R; Li XA; Lobdell J
    Med Phys; 2003 Jan; 30(1):27-33. PubMed ID: 12557975
    [TBL] [Abstract][Full Text] [Related]  

  • 5. A new treatment planning formalism for catheter-based beta sources used in intravascular brachytherapy.
    Patel NS; Chiu-Tsao ST; Tsao HS; Harrison LB
    Cardiovasc Radiat Med; 2001; 2(3):157-64. PubMed ID: 11786322
    [TBL] [Abstract][Full Text] [Related]  

  • 6. A semi-analytic approach to determine dose rate constant of brachytherapy sources in compliance with AAPM TG 60 formalism.
    Selvam TP; Nagarajan PS; Rajan KN; Sethulakshmi P; Bhatt BC
    Australas Phys Eng Sci Med; 2003 Dec; 26(4):179-84. PubMed ID: 14995063
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Monte carlo investigation of the dosimetric properties of the new 103Pd BrachySeedPd-103 Model Pd-1 source.
    Chan GH; Prestwich WV
    Med Phys; 2002 Sep; 29(9):1984-90. PubMed ID: 12349919
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The use of cylindrical coordinates for treatment planning parameters of an elongated 192Ir source.
    Patel NS; Chiu-Tsao ST; Fan P; Tsao HS; Liprie SF; Harrison LB
    Int J Radiat Oncol Biol Phys; 2001 Nov; 51(4):1093-102. PubMed ID: 11704334
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dosimetric accuracy of a deterministic radiation transport based 192Ir brachytherapy treatment planning system. Part I: single sources and bounded homogeneous geometries.
    Zourari K; Pantelis E; Moutsatsos A; Petrokokkinos L; Karaiskos P; Sakelliou L; Georgiou E; Papagiannis P
    Med Phys; 2010 Feb; 37(2):649-61. PubMed ID: 20229874
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Dosimetry of 192Ir wires for LDR interstitial brachytherapy following the AAPM TG-43 dosimetric formalism.
    Karaiskos P; Papagiannis P; Angelopoulos A; Sakelliou L; Baltas D; Sandilos P; Vlachos L
    Med Phys; 2001 Feb; 28(2):156-66. PubMed ID: 11243338
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Monte Carlo dosimetry of 60Co HDR brachytherapy sources.
    Papagiannis P; Angelopoulos A; Pantelis E; Sakelliou L; Karaiskos P; Shimizu Y
    Med Phys; 2003 Apr; 30(4):712-21. PubMed ID: 12722823
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A segmented 32P source Monte Carlo model to derive AAPM TG-60 dosimetric parameters used for intravascular brachytherapy.
    Mourtada F; Soares CG; Horton JL
    Med Phys; 2004 Mar; 31(3):602-8. PubMed ID: 15070260
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Update of AAPM Task Group No. 43 Report: A revised AAPM protocol for brachytherapy dose calculations.
    Rivard MJ; Coursey BM; DeWerd LA; Hanson WF; Huq MS; Ibbott GS; Mitch MG; Nath R; Williamson JF
    Med Phys; 2004 Mar; 31(3):633-74. PubMed ID: 15070264
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Technical note: fitted dosimetric parameters of high dose-rate 192Ir sources according to the AAPM TG43 formalism.
    Lliso F; Pérez-Calatayud J; Carmona V; Ballester F; Puchades V; Granero D
    Med Phys; 2003 Apr; 30(4):651-4. PubMed ID: 12722817
    [TBL] [Abstract][Full Text] [Related]  

  • 15. A Monte Carlo calculation of dosimetric parameters of 90Sr/90Y and 192Ir SS sources for intravascular brachytherapy.
    Wang R; Li XA
    Med Phys; 2000 Nov; 27(11):2528-35. PubMed ID: 11128305
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy assessment of the superposition principle for evaluating dose distributions of elongated and curved 103Pd and 192Ir brachytherapy sources.
    Bannon EA; Yang Y; Rivard MJ
    Med Phys; 2011 Jun; 38(6):2957-63. PubMed ID: 21815369
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Monte Carlo calculated TG-60 dosimetry parameters for the beta- emitter 153Sm brachytherapy source.
    Sadeghi M; Taghdiri F; Hosseini SH; Tenreiro C
    Med Phys; 2010 Oct; 37(10):5370-5. PubMed ID: 21089772
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Monte Carlo and thermoluminescence dosimetry of the new IsoSeed model I25.S17 125I interstitial brachytherapy seed.
    Lymperopoulou G; Papagiannis P; Sakelliou L; Karaiskos P; Sandilos P; Przykutta A; Baltas D
    Med Phys; 2005 Nov; 32(11):3313-7. PubMed ID: 16370418
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of GPUMCD for low-energy brachytherapy seed dosimetry.
    Hissoiny S; Ozell B; Després P; Carrier JF
    Med Phys; 2011 Jul; 38(7):4101-7. PubMed ID: 21859010
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measured TG-60 dosimetric parameters of the Novoste Beta-Cath 90Sr/Y source trains for intravascular brachytherapy.
    Roa DE; Song H; Yue N; D'Errico F; Nath R
    Cardiovasc Radiat Med; 2002; 3(3-4):199-204. PubMed ID: 12974374
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 15.