BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

135 related articles for article (PubMed ID: 12675337)

  • 1. A new analytical procedure for assay of lysozyme in human tear and saliva with immobilized reagents in flow injection chemiluminescence system.
    Song ZH; Hou S
    Anal Sci; 2003 Mar; 19(3):347-52. PubMed ID: 12675337
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A new green analytical procedure for monitoring sub-nanogram amounts of chlorpyrifos on fruits using flow injection chemiluminescence with immobilized reagents.
    Song Z; Hou S; Zhang N
    J Agric Food Chem; 2002 Jul; 50(16):4468-74. PubMed ID: 12137462
    [TBL] [Abstract][Full Text] [Related]  

  • 3. In vitro monitoring sub-nanogram amounts analgin in human urine by its inhibitory of the luminol-periodate chemiluminescence reaction using reagent immobilization release technique.
    Song Z; Zhang N
    Bioorg Med Chem; 2002 Jul; 10(7):2091-7. PubMed ID: 11983504
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Chemiluminescence investigation of detection of rutin in medicine and human urine using controlled-reagent-release technology.
    Song Z; Wang L
    J Agric Food Chem; 2001 Dec; 49(12):5697-701. PubMed ID: 11743749
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Chemiluminescence flow-through sensor for the determination of vitamin B2 using controlled-reagent-release technology.
    Wang L; Song ZH
    Yao Xue Xue Bao; 2002 Oct; 37(10):793-7. PubMed ID: 12567864
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Determination of picomole amounts of thiamine through flow-injection analysis based on the suppression of luminol-KIO(4) chemiluminescence system.
    Song Z; Hou S
    J Pharm Biomed Anal; 2002 May; 28(3-4):683-91. PubMed ID: 12008148
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Chemiluminescence assay for uric acid in human serum and urine using flow-injection with immobilized reagents technology.
    Song ZH; Hou S
    Anal Bioanal Chem; 2002 Jan; 372(2):327-32. PubMed ID: 11936107
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sensitive determination of sub-nanogram amounts of rutin by its inhibition on chemiluminescence with immobilized reagents.
    Song Z; Hou S
    Talanta; 2002 Apr; 57(1):59-67. PubMed ID: 18968605
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Chemiluminescence flow sensor for berberine with immobilized reagents.
    Song Z; Zhao T; Wang L; Xiao Z
    Bioorg Med Chem; 2001 Jul; 9(7):1701-5. PubMed ID: 11425570
    [TBL] [Abstract][Full Text] [Related]  

  • 10. An automatic chemiluminescence method based on the multi-pumping flow system coupled with the fluidized reactor and direct-injection detector: Determination of uric acid in saliva samples.
    Vakh C; Koronkiewicz S; Kalinowski S; Moskvin L; Bulatov A
    Talanta; 2017 May; 167():725-732. PubMed ID: 28340785
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Rapid determination of clindamycin in medicine with myoglobin-luminol chemiluminescence system.
    Shao X; Xie X; Liu Y; Song Z
    J Pharm Biomed Anal; 2006 May; 41(2):667-70. PubMed ID: 16439092
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Continuous, quantitative monitoring of roxithromycin in human saliva by flow injection chemiluminescence analysis.
    Tan X; Song Z
    Appl Spectrosc; 2013 Jan; 67(1):54-8. PubMed ID: 23317671
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Ultrasensitive assay of clindamycin in medicine and bio-fluids with chemiluminescence detection.
    Wei G; Dang G; Li H
    Luminescence; 2007; 22(6):534-9. PubMed ID: 17768707
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ultrasensitive assay of azithromycin in medicine and bio-fluids based on its enhanced luminol-H(2)O(2) chemiluminescence reaction using flow injection technique.
    Song Z; Wang C
    Bioorg Med Chem; 2003 Dec; 11(24):5375-80. PubMed ID: 14642581
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Reagentless chemiluminescence flow sensor for the determination of riboflavin in pharmaceutical preparations and human urine.
    Song Z; Wang L
    Analyst; 2001 Aug; 126(8):1393-8. PubMed ID: 11534612
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Chemiluminescence flow sensor for folic acid with immobilized reagents.
    Song Z; Zhou X
    Spectrochim Acta A Mol Biomol Spectrosc; 2001 Nov; 57(13):2567-74. PubMed ID: 11765783
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Flow injection chemiluninescence for detecting picogram amounts of dobesilate in human urine.
    Song Z; Yue Q; Wang C
    Spectrochim Acta A Mol Biomol Spectrosc; 2004 Aug; 60(10):2377-82. PubMed ID: 15249028
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Chemiluminescence sensor for isoniazid with controlled-reagent-release technology.
    Song Z; Lü J; Zhao T
    Talanta; 2001 Mar; 53(6):1171-7. PubMed ID: 18968210
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Sensitive determination of gentiopicroside in medicine and bio-fluids using luminol-myoglobin chemiluminescence combined with flow injection technique.
    He X; Xie X; Shao X; Song Z
    Luminescence; 2010; 25(5):384-8. PubMed ID: 19743525
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Chemiluminescence flow system for vanadium(v) with immobilized reagents.
    Qin W; Zhang Z; Zhang C
    Analyst; 1997 Jul; 122(7):685-8. PubMed ID: 9330039
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.