BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

149 related articles for article (PubMed ID: 12698728)

  • 21. Variability in time delay between two models of pulse oximeters for deriving the photoplethysmographic signals.
    Foo JY; Wilson SJ; Dakin C; Williams G; Harris MA; Cooper D
    Physiol Meas; 2005 Aug; 26(4):531-44. PubMed ID: 15886446
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Reflectance pulse oximetry from core body in neonates and infants: comparison to arterial blood oxygen saturation and to transmission pulse oximetry.
    Kugelman A; Wasserman Y; Mor F; Goldinov L; Geller Y; Bader D
    J Perinatol; 2004 Jun; 24(6):366-71. PubMed ID: 15057251
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Pulse oximetry: evolution and directions.
    Middleton PM; Henry JA
    Int J Clin Pract; 2000 Sep; 54(7):438-44. PubMed ID: 11070568
    [TBL] [Abstract][Full Text] [Related]  

  • 24. New-generation pulse oximetry in the care of critically ill patients.
    Giuliano KK; Higgins TL
    Am J Crit Care; 2005 Jan; 14(1):26-37; quiz 38-9. PubMed ID: 15608106
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Wavelength selection for low-saturation pulse oximetry.
    Mannheimer PD; Casciani JR; Fein ME; Nierlich SL
    IEEE Trans Biomed Eng; 1997 Mar; 44(3):148-58. PubMed ID: 9216128
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Meconium-stained amniotic fluid and fetal oxygen saturation measured by pulse oximetry during labour.
    Grignaffini A; Soncini E; Ronzoni E; Piazza E; Anfuso S; Vadora E
    Acta Biomed; 2004; 75 Suppl 1():45-52. PubMed ID: 15301290
    [TBL] [Abstract][Full Text] [Related]  

  • 27. False alarms and sensitivity of conventional pulse oximetry versus the Masimo SET technology in the pediatric postanesthesia care unit.
    Malviya S; Reynolds PI; Voepel-Lewis T; Siewert M; Watson D; Tait AR; Tremper K
    Anesth Analg; 2000 Jun; 90(6):1336-40. PubMed ID: 10825316
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Detection of a systolic pressure threshold for reliable readings in pulse oximetry.
    Hinkelbein J; Genzwuerker HV; Fiedler F
    Resuscitation; 2005 Mar; 64(3):315-9. PubMed ID: 15733760
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Clinical evaluation of a prototype motion artifact resistant pulse oximeter in the recovery room.
    Dumas C; Wahr JA; Tremper KK
    Anesth Analg; 1996 Aug; 83(2):269-72. PubMed ID: 8694304
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The OxiMax System. Nellcor's new platform for pulse oximetry.
    Mannheimer PD; Bebout DE
    Minerva Anestesiol; 2002 Apr; 68(4):236-9. PubMed ID: 12024089
    [TBL] [Abstract][Full Text] [Related]  

  • 31. [A comparative study of five pulse oximeters].
    Shitikov II; Flerov EV; Arsen'ev SB
    Med Tekh; 1993; (1):21-4. PubMed ID: 8502136
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Masimo signal extraction pulse oximetry.
    Goldman JM; Petterson MT; Kopotic RJ; Barker SJ
    J Clin Monit Comput; 2000; 16(7):475-83. PubMed ID: 12580205
    [TBL] [Abstract][Full Text] [Related]  

  • 33. "Motion-resistant" pulse oximetry: a comparison of new and old models.
    Barker SJ
    Anesth Analg; 2002 Oct; 95(4):967-72, table of contents. PubMed ID: 12351278
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of oesophageal reflectance pulse oximetry in major burns patients.
    Pal SK; Kyriacou PA; Kumaran S; Fadheel S; Emamdee R; Langford RM; Jones DP
    Burns; 2005 May; 31(3):337-41. PubMed ID: 15774290
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Principles and limitations of pulse oximetry in patient monitoring.
    Allen K
    Nurs Times; 2004 Oct 12-18; 100(41):34-7. PubMed ID: 15517733
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Design and validation of a pulse oximeter calibrator.
    Hornberger C; Matz H; Konecny E; Frankenberger H; Bonk R; Avgerinos J; Benekos K; Valais J; Ikiades A; Gil-Rodriguez J; Wouters P; Meyfroidt G; Ponz L; Gehring H
    Anesth Analg; 2002 Jan; 94(1 Suppl):S8-12. PubMed ID: 11900044
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Pulse oximetry theory and calibration for low saturations.
    Zonios G; Shankar U; Iyer VK
    IEEE Trans Biomed Eng; 2004 May; 51(5):818-22. PubMed ID: 15132508
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Advantages of new technology pulse oximetry with adults in extremis.
    Durbin CG; Rostow SK
    Anesth Analg; 2002 Jan; 94(1 Suppl):S81-3. PubMed ID: 11900045
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Continuous pulse oximetry in the general surgical ward: Nellcor N-200 versus Nellcor N-3000.
    Christensen M; Lie C; Rosenberg J
    Anaesthesia; 1999 Mar; 54(3):253-7. PubMed ID: 10364861
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Pulse oximeters.
    Cowan T
    Prof Nurse; 1997 Jul; 12(10):744-8, 750. PubMed ID: 9248457
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.