BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 12701891)

  • 1. CT calibration for two-dimensional scaling of proton pencil beams.
    Szymanowski H; Oelfke U
    Phys Med Biol; 2003 Apr; 48(7):861-74. PubMed ID: 12701891
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A generalized 2D pencil beam scaling algorithm for proton dose calculation in heterogeneous slab geometries.
    Westerly DC; Mo X; Tomé WA; Mackie TR; DeLuca PM
    Med Phys; 2013 Jun; 40(6):061706. PubMed ID: 23718585
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Improved calibration of mass stopping power in low density tissue for a proton pencil beam algorithm.
    Warren DR; Partridge M; Hill MA; Peach K
    Phys Med Biol; 2015 Jun; 60(11):4243-61. PubMed ID: 25973866
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Dosimetric comparison of stopping power calibration with dual-energy CT and single-energy CT in proton therapy treatment planning.
    Zhu J; Penfold SN
    Med Phys; 2016 Jun; 43(6):2845-2854. PubMed ID: 27277033
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Accurate proton treatment planning for pencil beam crossing titanium fixation implants.
    Righetto R; Clemens LP; Lorentini S; Fracchiolla F; Algranati C; Tommasino F; Dionisi F; Cianchetti M; Schwarz M; Farace P
    Phys Med; 2020 Feb; 70():28-38. PubMed ID: 31954210
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Two-dimensional pencil beam scaling: an improved proton dose algorithm for heterogeneous media.
    Szymanowski H; Oelfke U
    Phys Med Biol; 2002 Sep; 47(18):3313-30. PubMed ID: 12375823
    [TBL] [Abstract][Full Text] [Related]  

  • 7. A fourier analysis on the maximum acceptable grid size for discrete proton beam dose calculation.
    Li HS; Romeijn HE; Dempsey JF
    Med Phys; 2006 Sep; 33(9):3508-18. PubMed ID: 17022247
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Experimental evaluation of a spatial resampling technique to improve the accuracy of pencil-beam dose calculation in proton therapy.
    Egashira Y; Nishio T; Matsuura T; Kameoka S; Uesaka M
    Med Phys; 2012 Jul; 39(7):4104-14. PubMed ID: 22830743
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Assessing the effect of electron density in photon dose calculations.
    Seco J; Evans PM
    Med Phys; 2006 Feb; 33(2):540-52. PubMed ID: 16532961
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Regularised patient-specific stopping power calibration for proton therapy planning based on proton radiographic images.
    Krah N; Patera V; Rit S; Schiavi A; Rinaldi I
    Phys Med Biol; 2019 Mar; 64(6):065008. PubMed ID: 30708365
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optimization of the stopping-power-ratio to Hounsfield-value calibration curve in proton and heavy ion therapy.
    Witt M; Weber U; Kellner D; Engenhart-Cabillic R; Zink K
    Z Med Phys; 2015 Sep; 25(3):251-63. PubMed ID: 25497583
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Validation of the proton range accuracy and optimization of CT calibration curves utilizing range probing.
    Meijers A; Free J; Wagenaar D; Deffet S; Knopf AC; Langendijk JA; Both S
    Phys Med Biol; 2020 Feb; 65(3):03NT02. PubMed ID: 31896099
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A pencil beam algorithm for magnetic resonance image-guided proton therapy.
    Padilla-Cabal F; Georg D; Fuchs H
    Med Phys; 2018 May; 45(5):2195-2204. PubMed ID: 29532490
    [TBL] [Abstract][Full Text] [Related]  

  • 14. A stoichiometric calibration method for dual energy computed tomography.
    Bourque AE; Carrier JF; Bouchard H
    Phys Med Biol; 2014 Apr; 59(8):2059-88. PubMed ID: 24694786
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Commissioning an in-room mobile CT for adaptive proton therapy with a compact proton system.
    Oliver JA; Zeidan O; Meeks SL; Shah AP; Pukala J; Kelly P; Ramakrishna NR; Willoughby TR
    J Appl Clin Med Phys; 2018 May; 19(3):149-158. PubMed ID: 29682879
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Monte Carlo proton dose calculations using a radiotherapy specific dual-energy CT scanner for tissue segmentation and range assessment.
    Almeida IP; Schyns LEJR; Vaniqui A; van der Heyden B; Dedes G; Resch AF; Kamp F; Zindler JD; Parodi K; Landry G; Verhaegen F
    Phys Med Biol; 2018 May; 63(11):115008. PubMed ID: 29616662
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Correction of CT artifacts and its influence on Monte Carlo dose calculations.
    Bazalova M; Beaulieu L; Palefsky S; Verhaegena F
    Med Phys; 2007 Jun; 34(6):2119-32. PubMed ID: 17654915
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Application of the pencil-beam redefinition algorithm in heterogeneous media for proton beam therapy.
    Egashira Y; Nishio T; Hotta K; Kohno R; Uesaka M
    Phys Med Biol; 2013 Feb; 58(4):1169-84. PubMed ID: 23370731
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Comparison of proton therapy treatment planning for head tumors with a pencil beam algorithm on dual and single energy CT images.
    Hudobivnik N; Schwarz F; Johnson T; Agolli L; Dedes G; Tessonnier T; Verhaegen F; Thieke C; Belka C; Sommer WH; Parodi K; Landry G
    Med Phys; 2016 Jan; 43(1):495. PubMed ID: 26745942
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Dose to 'water-like' media or dose to tissue in MV photons radiotherapy treatment planning: still a matter of debate.
    Andreo P
    Phys Med Biol; 2015 Jan; 60(1):309-37. PubMed ID: 25503312
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.