These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

112 related articles for article (PubMed ID: 12701894)

  • 41. A pencil beam dose calculation model for CyberKnife system.
    Liang B; Li Y; Liu B; Zhou F; Xu S; Wu Q
    Med Phys; 2016 Oct; 43(10):5380. PubMed ID: 27782698
    [TBL] [Abstract][Full Text] [Related]  

  • 42. Characterization of megavoltage electron beams delivered through a photon multi-leaf collimator (pMLC).
    du Plessis FC; Leal A; Stathakis S; Xiong W; Ma CM
    Phys Med Biol; 2006 Apr; 51(8):2113-29. PubMed ID: 16585849
    [TBL] [Abstract][Full Text] [Related]  

  • 43. Monte Carlo simulation of beam characteristics from small fields based on TrueBeam flattening-filter-free mode.
    Feng Z; Yue H; Zhang Y; Wu H; Cheng J; Su X
    Radiat Oncol; 2016 Feb; 11():30. PubMed ID: 26921246
    [TBL] [Abstract][Full Text] [Related]  

  • 44. Modelling lateral beam quality variations in pencil kernel based photon dose calculations.
    Nyholm T; Olofsson J; Ahnesjö A; Karlsson M
    Phys Med Biol; 2006 Aug; 51(16):4111-8. PubMed ID: 16885628
    [TBL] [Abstract][Full Text] [Related]  

  • 45. [Electron fields in clinical application. A comparison of pencil beam and Monte Carlo algorithm].
    Treutwein M; Bogner L
    Strahlenther Onkol; 2007 Aug; 183(8):454-8. PubMed ID: 17680226
    [TBL] [Abstract][Full Text] [Related]  

  • 46. Electron beam collimation with a photon MLC for standard electron treatments.
    Mueller S; Fix MK; Henzen D; Frei D; Frauchiger D; Loessl K; Stampanoni MFM; Manser P
    Phys Med Biol; 2018 Jan; 63(2):025017. PubMed ID: 29214984
    [TBL] [Abstract][Full Text] [Related]  

  • 47. Modeling the truebeam linac using a CAD to Geant4 geometry implementation: dose and IAEA-compliant phase space calculations.
    Constantin M; Perl J; LoSasso T; Salop A; Whittum D; Narula A; Svatos M; Keall PJ
    Med Phys; 2011 Jul; 38(7):4018-24. PubMed ID: 21858999
    [TBL] [Abstract][Full Text] [Related]  

  • 48. Determining the incident electron fluence for Monte Carlo-based photon treatment planning using a standard measured data set.
    Keall PJ; Siebers JV; Libby B; Mohan R
    Med Phys; 2003 Apr; 30(4):574-82. PubMed ID: 12722809
    [TBL] [Abstract][Full Text] [Related]  

  • 49. A Monte Carlo based source model for dose calculation of endovaginal TARGIT brachytherapy with INTRABEAM and a cylindrical applicator.
    Clausen S; Schneider F; Jahnke L; Fleckenstein J; Hesser J; Glatting G; Wenz F
    Z Med Phys; 2012 Sep; 22(3):197-204. PubMed ID: 22739321
    [TBL] [Abstract][Full Text] [Related]  

  • 50. Influence of initial electron beam parameters on Monte Carlo calculated absorbed dose distributions for radiotherapy photon beams.
    Tzedakis A; Damilakis JE; Mazonakis M; Stratakis J; Varveris H; Gourtsoyiannis N
    Med Phys; 2004 Apr; 31(4):907-13. PubMed ID: 15125009
    [TBL] [Abstract][Full Text] [Related]  

  • 51. An inhomogeneity correction algorithm for irregular fields of high-energy photon beams based on Clarkson integration and the 3D beam subtraction method.
    Stathakis S; Kappas C; Theodorou K; Papanikolaou N; Rosenwald JC
    J Appl Clin Med Phys; 2006; 7(1):1-13. PubMed ID: 16518312
    [TBL] [Abstract][Full Text] [Related]  

  • 52. Preliminary testing of GaN-based dosimeters for electron beam radiotherapy.
    Ismail A; Wang R; Chaikh A; Pittet P; Balosso J
    Radiat Prot Dosimetry; 2015 Jul; 165(1-4):488-91. PubMed ID: 25813482
    [TBL] [Abstract][Full Text] [Related]  

  • 53. Clinical implementation of an empirical method for electron output factor determination.
    Johnson DA; Ahmad S
    J Xray Sci Technol; 2010; 18(3):309-18. PubMed ID: 20714088
    [TBL] [Abstract][Full Text] [Related]  

  • 54. Dosimetric characteristics of backscattered electrons in lead.
    Pérez-Calatayudt J; Ballester F; Serrano MA; Lluch JL; Casal E; Carmona V
    Phys Med Biol; 2000 Jul; 45(7):1841-9. PubMed ID: 10943922
    [TBL] [Abstract][Full Text] [Related]  

  • 55. A method of scaling the 3D electron pencil-beam dose calculation to obtain accurate monitor units for irregularly-shaped electron beams.
    McNutt TR; Tomé WA
    Med Dosim; 2002; 27(3):209-13. PubMed ID: 12374377
    [TBL] [Abstract][Full Text] [Related]  

  • 56. Dose accuracy check of the 3D electron beam algorithm in a treatment planning system.
    Samuelsson A; Hyödynmaa S; Johansson KA
    Phys Med Biol; 1998 Jun; 43(6):1529-44. PubMed ID: 9651023
    [TBL] [Abstract][Full Text] [Related]  

  • 57. Numerical calculation of energy deposition by high-energy electron beams: III. Three-dimensional heterogeneous media.
    Janssen JJ; Riedeman DE; Morawska-Kaczyńska M; Storchi PR; Huizenga H
    Phys Med Biol; 1994 Sep; 39(9):1351-66. PubMed ID: 15552109
    [TBL] [Abstract][Full Text] [Related]  

  • 58. Accuracy of the phase space evolution dose calculation model for clinical 25 MeV electron beams.
    Korevaar EW; Akhiat A; Heijmen BJ; Huizenga H
    Phys Med Biol; 2000 Oct; 45(10):2931-45. PubMed ID: 11049181
    [TBL] [Abstract][Full Text] [Related]  

  • 59. A sector-integration method for calculating the output factors of irregularly shaped electron fields.
    Jursinic PA; Mueller R
    Med Phys; 1997 Nov; 24(11):1765-9. PubMed ID: 9394283
    [TBL] [Abstract][Full Text] [Related]  

  • 60. Calculation of electron and isotopes dose point kernels with FLUKA Monte Carlo code for dosimetry in nuclear medicine therapy.
    Botta F; Mairani A; Battistoni G; Cremonesi M; Di Dia A; Fassò A; Ferrari A; Ferrari M; Paganelli G; Pedroli G; Valente M
    Med Phys; 2011 Jul; 38(7):3944-54. PubMed ID: 21858991
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.