These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

117 related articles for article (PubMed ID: 12701913)

  • 1. Portable pilot plant for evaluating marine biofouling growth and control in heat exchangers-condensers.
    Casanueva JF; Sánchez J; García-Morales JL; Casanueva-Robles T; López JA; Portela JR; Nebot E; Sales D
    Water Sci Technol; 2003; 47(5):99-104. PubMed ID: 12701913
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Combined monitor for direct and indirect measurement of biofouling.
    Eguía E; Trueba A; Río-Calonge B; Girón A; Amieva JJ; Bielva C
    Biofouling; 2008; 24(2):75-86. PubMed ID: 18167032
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Mitigation of biofouling using electromagnetic fields in tubular heat exchangers-condensers cooled by seawater.
    Trueba A; García S; Otero FM
    Biofouling; 2014 Jan; 30(1):95-103. PubMed ID: 24266611
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Optimisation of biocide dose as a function of residual biocide in a heat exchanger pilot plant effluent.
    Eguía E; Trueba A; Girón A; Río-Calonge B; Otero F; Bielva C
    Biofouling; 2007; 23(3-4):231-47. PubMed ID: 17653933
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Investigation of biocide efficacy by photoacoustic biofilm monitoring.
    Schmid T; Panne U; Adams J; Niessner R
    Water Res; 2004 Mar; 38(5):1189-96. PubMed ID: 14975652
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Study of the activity of quaternary ammonium compounds in the mitigation of biofouling in heat exchangers-condensers cooled by seawater.
    Trueba A; Otero FM; González JA; Vega LM; García S
    Biofouling; 2013; 29(9):1139-51. PubMed ID: 24067104
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Impact of the surface roughness of AISI 316L stainless steel on biofilm adhesion in a seawater-cooled tubular heat exchanger-condenser.
    García S; Trueba A; Vega LM; Madariaga E
    Biofouling; 2016 Nov; 32(10):1185-1193. PubMed ID: 27744709
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Efficacy of different antifouling treatments for seawater cooling systems.
    López-Galindo C; Casanueva JF; Nebot E
    Biofouling; 2010 Nov; 26(8):923-30. PubMed ID: 21038152
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Biofouling assessment using an infrared monitor.
    Tinham P; Bott TR
    Water Sci Technol; 2003; 47(5):39-43. PubMed ID: 12701904
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The impact of fouling on the process performance of the thermal treatment of pig slurry using tubular heat exchangers.
    Cunault C; Burton CH; Pourcher AM
    J Environ Manage; 2013 Mar; 117():253-62. PubMed ID: 23376308
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mitigation of marine biofouling on tubes of open rack vaporizers using electromagnetic fields.
    Trueba A; Vega LM; García S; Otero FM; Madariaga E
    Water Sci Technol; 2016; 73(5):1221-9. PubMed ID: 26942546
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Effects of operating conditions on the adhesive strength of Pseudomonas fluorescens biofilms in tubes.
    Chen MJ; Zhang Z; Bott TR
    Colloids Surf B Biointerfaces; 2005 Jun; 43(2):61-71. PubMed ID: 15913966
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Role and levels of real-time monitoring for successful anti-fouling strategies--an overview.
    Flemming HC
    Water Sci Technol; 2003; 47(5):1-8. PubMed ID: 12701899
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of calcium ions on the evolution of biofouling by Bacillus subtilis in plate heat exchangers simulating the heat pump system used with treated sewage in the 2008 Olympic Village.
    Tian L; Chen XD; Yang QP; Chen JC; Shi L; Li Q
    Colloids Surf B Biointerfaces; 2012 Jun; 94():309-16. PubMed ID: 22391321
    [TBL] [Abstract][Full Text] [Related]  

  • 15. On-line monitoring of biofilm formation in a brewery water pipeline system with a fibre optical device.
    Tamachkiarow L; Flemming HC
    Water Sci Technol; 2003; 47(5):19-24. PubMed ID: 12701901
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A new predictive dynamic model describing the effect of the ambient temperature and the convective heat transfer coefficient on bacterial growth.
    Ben Yaghlene H; Leguerinel I; Hamdi M; Mafart P
    Int J Food Microbiol; 2009 Jul; 133(1-2):48-61. PubMed ID: 19447512
    [TBL] [Abstract][Full Text] [Related]  

  • 17. On-line biofilm monitoring by "BIOX" electrochemical probe.
    Mollica A; Cristiani P
    Water Sci Technol; 2003; 47(5):45-9. PubMed ID: 12701905
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Experimental investigation of interactions between the temperature field and biofouling in a synthetic treated sewage stream.
    Yang Q; Wilson DI; Chen X; Shi L
    Biofouling; 2013; 29(5):513-23. PubMed ID: 23668358
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The effect of electromagnetic fields on biofouling in a heat exchange system using seawater.
    Trueba A; García S; Otero FM; Vega LM; Madariaga E
    Biofouling; 2015; 31(1):19-26. PubMed ID: 25567299
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Biofouling in water systems--cases, causes and countermeasures.
    Flemming HC
    Appl Microbiol Biotechnol; 2002 Sep; 59(6):629-40. PubMed ID: 12226718
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.