These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
119 related articles for article (PubMed ID: 12708219)
1. [Use of a Cook-type tube exchanger in extubation in a patient with difficult intubation]. Aragonès N; Torres-Bahí S; Metje T; Navarro-Egea M Rev Esp Anestesiol Reanim; 2003 Mar; 50(3):163-4. PubMed ID: 12708219 [No Abstract] [Full Text] [Related]
2. Use of the Cook airway exchange catheter in "bridging" the potentially difficult extubation: a case report. Moyers G; McDougle L AANA J; 2002 Aug; 70(4):275-8. PubMed ID: 12242925 [TBL] [Abstract][Full Text] [Related]
3. Utility of the Portex introducer, ivory type, as a tube exchanger. Sanuki T; Son H; Kishimoto N; Kotani J J Oral Maxillofac Surg; 2009 Aug; 67(8):1615-8. PubMed ID: 19615572 [TBL] [Abstract][Full Text] [Related]
4. Use of a tracheal tube exchanger for submento-tracheal intubation. Malhotra N Anaesthesia; 2005 Aug; 60(8):828. PubMed ID: 16029252 [No Abstract] [Full Text] [Related]
5. A secure method of nasal endotracheal tube stabilization with suture and rubber tube. Ota Y; Karakida K; Aoki T; Yamazaki H; Arai I; Mori Y; Nakatogawa N; Suzuki T Tokai J Exp Clin Med; 2001 Dec; 26(4-6):119-22. PubMed ID: 12030440 [TBL] [Abstract][Full Text] [Related]
6. [Utilization of continuous airflow in a case of air loss in the internal cuff of the endotracheal tube after a difficult intubation]. Suárez Artamendi JR; Gutiérrez Fernández MJ; Bermejo González JC; Bronte Borraz E; García-Miguel Sánchez C; Pelegrín Arenillas A Rev Esp Anestesiol Reanim; 1998; 45(6):257-8. PubMed ID: 9719728 [No Abstract] [Full Text] [Related]
7. [Extubation of the difficult airway]. de la Linde Valverde CM Rev Esp Anestesiol Reanim; 2005 Nov; 52(9):557-70; quiz 570, 582. PubMed ID: 16363303 [TBL] [Abstract][Full Text] [Related]
8. The Airway Scope for difficult double-lumen tube intubation. Poon KH; Liu EH J Clin Anesth; 2008 Jun; 20(4):319. PubMed ID: 18617138 [No Abstract] [Full Text] [Related]
9. [Airway access using an endotracheal tube changer for safe extubation in an infant with a difficult airway]. Kira S; Miyakawa H; Mori M; Hidaka S; Noguchi T; Fujisawa H Masui; 2008 Feb; 57(2):167-70. PubMed ID: 18277563 [TBL] [Abstract][Full Text] [Related]
10. GlideScope-assisted double-lumen endobronchial tube placement in a patient with an unanticipated difficult airway. Chen A; Lai HY; Lin PC; Chen TY; Shyr MH J Cardiothorac Vasc Anesth; 2008 Feb; 22(1):170-2. PubMed ID: 18249357 [No Abstract] [Full Text] [Related]
14. [Exchanging and maintaining the airway in hyoid surgery: using a flexible exchanger during new surgical treatments for obstructive sleep apnea syndrome]. Longás Valién J; Martínez Ubieto J; Muñoz Rodríguez L; Ortega Lucea S; Guerrero Pardos LM; Vicente González E; Quesada Gimeno N Rev Esp Anestesiol Reanim; 2005 Mar; 52(3):149-53. PubMed ID: 15850302 [TBL] [Abstract][Full Text] [Related]
15. Successful airway management of a patient with a known difficult airway with the Direct Coupler Interface Video Laryngoscope. Hagberg CA; Vogt-Harenkamp CC; Iannucci DG J Clin Anesth; 2007 Dec; 19(8):629-31. PubMed ID: 18083480 [TBL] [Abstract][Full Text] [Related]
16. [Difficulties in extubation--example of an extubation hindrance caused by a stomach tube]. Kulka P; Rommelsheim K Anasth Intensivther Notfallmed; 1987 Feb; 22(1):37-8. PubMed ID: 3578722 [TBL] [Abstract][Full Text] [Related]