These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 12710320)

  • 1. The defibrillation efficacy of high frequency alternating current sinusoidal waveforms in guinea pigs.
    Roberts SJ; Guan D; Malkin R
    Pacing Clin Electrophysiol; 2003 Feb; 26(2 Pt 1):599-604. PubMed ID: 12710320
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Large sample test of defibrillation waveform sensitivity.
    Malkin RA
    J Cardiovasc Electrophysiol; 2002 Apr; 13(4):361-70. PubMed ID: 12033353
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The effects of phase duration on defibrillation success of dual time constant biphasic waveforms.
    Shan Y; Ristagno G; Fuller M; Sun S; Li Y; Weil MH; Russell J; Tang W
    Resuscitation; 2010 Feb; 81(2):236-41. PubMed ID: 19945206
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Defibrillation using a high-frequency series of monophasic rectangular pulses: observations and model predictions.
    Sweeney RJ; Gill RM; Jones JL; Reid PR
    J Cardiovasc Electrophysiol; 1996 Feb; 7(2):134-43. PubMed ID: 8853023
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Experimental verification of theoretical predictions concerning the optimum defibrillation waveform.
    Malkin RA; Jackson SR; Nguyen J; Yang Z; Guan D
    IEEE Trans Biomed Eng; 2006 Aug; 53(8):1492-8. PubMed ID: 16916083
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Analysis of the defibrillation efficacy for 5-ms waveforms.
    Guan D; Malkin R
    J Cardiovasc Electrophysiol; 2004 Apr; 15(4):447-54. PubMed ID: 15089995
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Strength-duration and probability of success curves for defibrillation with biphasic waveforms.
    Feeser SA; Tang AS; Kavanagh KM; Rollins DL; Smith WM; Wolf PD; Ideker RE
    Circulation; 1990 Dec; 82(6):2128-41. PubMed ID: 2242537
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Ventricular defibrillation using biphasic waveforms: the importance of phasic duration.
    Tang AS; Yabe S; Wharton JM; Dolker M; Smith WM; Ideker RE
    J Am Coll Cardiol; 1989 Jan; 13(1):207-14. PubMed ID: 2909569
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Relative efficacy of monophasic and biphasic waveforms for transthoracic defibrillation after short and long durations of ventricular fibrillation.
    Walcott GP; Melnick SB; Chapman FW; Jones JL; Smith WM; Ideker RE
    Circulation; 1998 Nov; 98(20):2210-5. PubMed ID: 9815877
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A prospective randomized evaluation of biphasic versus monophasic waveform pulses on defibrillation efficacy in humans.
    Bardy GH; Ivey TD; Allen MD; Johnson G; Mehra R; Greene HL
    J Am Coll Cardiol; 1989 Sep; 14(3):728-33. PubMed ID: 2768721
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biphasic waveforms for ventricular defibrillation: optimization of total pulse and second phase durations.
    Matula MH; Brooks MJ; Pan Q; Pless BD; Province RA; Echt DS
    Pacing Clin Electrophysiol; 1997 Sep; 20(9 Pt 1):2154-62. PubMed ID: 9309738
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optimizing defibrillation waveforms for ICDs.
    Kroll MW; Swerdlow CD
    J Interv Card Electrophysiol; 2007 Apr; 18(3):247-63. PubMed ID: 17541815
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Low-tilt monophasic and biphasic waveforms compared with standard biphasic waveforms in the transvenous defibrillation of ventricular fibrillation.
    Bennett JR; Darragh KM; Walsh SJ; Allen DJ; Scott M; Stevenson M; Adgey JA; Anderson JM; Manoharan G
    Pacing Clin Electrophysiol; 2014 Mar; 37(3):279-89. PubMed ID: 24102186
    [TBL] [Abstract][Full Text] [Related]  

  • 14. External exponential biphasic versus monophasic shock waveform: efficacy in ventricular fibrillation of longer duration.
    Yamanouchi Y; Brewer JE; Donohoo AM; Mowrey KA; Wilkoff BL; Tchou PJ
    Pacing Clin Electrophysiol; 1999 Oct; 22(10):1481-7. PubMed ID: 10588150
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Average current is better than peak current as therapeutic dosage for biphasic waveforms in a ventricular fibrillation pig model of cardiac arrest.
    Chen B; Yu T; Ristagno G; Quan W; Li Y
    Resuscitation; 2014 Oct; 85(10):1399-404. PubMed ID: 25010783
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Internal cardioversion of atrial fibrillation in sheep.
    Cooper RA; Alferness CA; Smith WM; Ideker RE
    Circulation; 1993 May; 87(5):1673-86. PubMed ID: 8491023
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Strength-duration curves of fixed pulse width variable tilt truncated exponential waveforms for nonthoracotomy internal defibrillation in dogs.
    Chapman PD; Wetherbee JN; Vetter JW; Troup P; Souza J
    Pacing Clin Electrophysiol; 1988 Jul; 11(7):1045-50. PubMed ID: 2457883
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Improved defibrillation thresholds with large contoured epicardial electrodes and biphasic waveforms.
    Dixon EG; Tang AS; Wolf PD; Meador JT; Fine MJ; Calfee RV; Ideker RE
    Circulation; 1987 Nov; 76(5):1176-84. PubMed ID: 3665001
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Is the second phase of a biphasic defibrillation waveform the defibrillating phase?
    Hillsley RE; Walker RG; Swanson DK; Rollins DL; Wolf PD; Smith WM; Ideker RE
    Pacing Clin Electrophysiol; 1993 Jul; 16(7 Pt 1):1401-11. PubMed ID: 7689206
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Increasing fibrillation duration enhances relative asymmetrical biphasic versus monophasic defibrillator waveform efficacy.
    Jones JL; Swartz JF; Jones RE; Fletcher R
    Circ Res; 1990 Aug; 67(2):376-84. PubMed ID: 2376078
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.