2. Development of a slurry introduction method for multi-element analysis of antibiotics by inductively coupled plasma atomic emission spectrometry using various types of spray chamber and nebulizer configurations. Zachariadis GA; Michos CE J Pharm Biomed Anal; 2007 Feb; 43(3):951-8. PubMed ID: 17045773 [TBL] [Abstract][Full Text] [Related]
3. A microwave-powered thermospray nebulizer for liquid sample introduction in inductively coupled plasma atomic emission spectrometry. Bordera L; Todolí JL; Mora J; Canals A; Hernandis V Anal Chem; 1997 Sep; 69(17):3578-86. PubMed ID: 21639282 [TBL] [Abstract][Full Text] [Related]
4. [Analytical figures of merit of Hildebrand grid and ultrasonic nebulizations in inductively coupled plasma atomic emission]. Tian M; Han XY; Zhuo SJ; Zhang RR Guang Pu Xue Yu Guang Pu Fen Xi; 2012 May; 32(5):1376-80. PubMed ID: 22827093 [TBL] [Abstract][Full Text] [Related]
5. Determination of impurities in highly pure platinum by inductively coupled plasma-atomic emission spectrometry. Zhang X; Li H; Yang Y Talanta; 1995 Dec; 42(12):1959-63. PubMed ID: 18966438 [TBL] [Abstract][Full Text] [Related]
12. A simple and demountable capillary microflow nebulizer with a tapered tip for inductively coupled plasma mass spectrometry. Cheng H; Yin X; Xu Z; Wang X; Shen H Talanta; 2011 Jul; 85(1):794-9. PubMed ID: 21645775 [TBL] [Abstract][Full Text] [Related]
14. Development of a rapid multi-element method of analysis of antitussive syrups by inductively coupled plasma atomic emission spectrometry and direct sample introduction. Zachariadis GA; Kapsimali DC J Pharm Biomed Anal; 2006 Jun; 41(4):1212-9. PubMed ID: 16621409 [TBL] [Abstract][Full Text] [Related]
15. Determination of metal impurities in advanced lead zirconate titanate ceramics by axial view mode inductively coupled plasma optical emission spectrometry. Villanueva Tagle ME; Larrea Marín MT; Martin Gavilán O; Durruthy Rodríguez MD; Calderón Piñar F; Pomares Alfonso MS Talanta; 2012 May; 94():50-7. PubMed ID: 22608413 [TBL] [Abstract][Full Text] [Related]
17. Comparison of several spray chambers operating at very low liquid flow rates in inductively coupled plasma atomic emission spectrometry. Todolí JL; Maestre S; Mora J; Canals A; Hernandis V Fresenius J Anal Chem; 2000 Dec; 368(8):773-9. PubMed ID: 11227562 [TBL] [Abstract][Full Text] [Related]
18. Inductively coupled plasma-mass spectrometry as an element-specific detector for field-flow fractionation particle separation. Taylor HE; Garbarino JR; Murphy DM; Beckett R Anal Chem; 1992 Sep; 64(18):2036-41. PubMed ID: 19518039 [TBL] [Abstract][Full Text] [Related]
19. [Adaptability of Different Nebulizer Systems to Different Silicon Chemical Forms for Gasoline in Inductively Coupled Plasma Optical Emission Spectrometry]. Zhao Y; Chen XY; Xu DY; Zhang SY; Liao J Guang Pu Xue Yu Guang Pu Fen Xi; 2016 Oct; 36(10):3303-7. PubMed ID: 30246970 [TBL] [Abstract][Full Text] [Related]
20. Determination of trace impurities in uranium, thorium and plutonium matrices by solvent extraction and inductively coupled plasma atomic emission spectrometry. Gopalkrishnan M; Radhakrishnan K; Dhami PS; Kulkarni VT; Joshi MV; Patwardhan AB; Ramanujam A; Mathur JN Talanta; 1997 Feb; 44(2):169-76. PubMed ID: 18966731 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]