273 related articles for article (PubMed ID: 12728033)
1. Cyclic loading of olecranon fracture fixation constructs.
Hutchinson DT; Horwitz DS; Ha G; Thomas CW; Bachus KN
J Bone Joint Surg Am; 2003 May; 85(5):831-7. PubMed ID: 12728033
[TBL] [Abstract][Full Text] [Related]
2. Olecranon fractures repaired with FiberWire or metal wire tension banding: a biomechanical comparison.
Carofino BC; Santangelo SA; Kabadi M; Mazzocca AD; Browner BD
Arthroscopy; 2007 Sep; 23(9):964-70. PubMed ID: 17868835
[TBL] [Abstract][Full Text] [Related]
3. Transcortical screw fixation of the olecranon shows equivalent strength and improved stability compared with tension band fixation.
Jones TB; Karenz AR; Weinhold PS; Dahners LE
J Orthop Trauma; 2014 Mar; 28(3):137-42. PubMed ID: 23681413
[TBL] [Abstract][Full Text] [Related]
4. Displaced olecranon fractures in children: a biomechanical analysis of fixation methods.
Parent S; Wedemeyer M; Mahar AT; Anderson M; Faro F; Steinman S; Lalonde F; Newton P
J Pediatr Orthop; 2008 Mar; 28(2):147-51. PubMed ID: 18388706
[TBL] [Abstract][Full Text] [Related]
5. Biomechanical comparison of fixation methods in transverse olecranon fractures: a cadaveric study.
Prayson MJ; Williams JL; Marshall MP; Scilaris TA; Lingenfelter EJ
J Orthop Trauma; 1997 Nov; 11(8):565-72. PubMed ID: 9415862
[TBL] [Abstract][Full Text] [Related]
6. Biomechanical evaluation of the tension band wiring principle. A comparison between two different techniques for transverse patella fracture fixation.
Zderic I; Stoffel K; Sommer C; Höntzsch D; Gueorguiev B
Injury; 2017 Aug; 48(8):1749-1757. PubMed ID: 28622833
[TBL] [Abstract][Full Text] [Related]
7. Is the novel olecranon tension plate a valid alternative to tension band wiring of olecranon fractures? A biomechanical study on cadaver bones.
Gruszka D; Arand C; Greenfield J; Nowak TE; Kuechle R; Kuhn S; Rommens PM
Arch Orthop Trauma Surg; 2017 Dec; 137(12):1651-1658. PubMed ID: 28864862
[TBL] [Abstract][Full Text] [Related]
8. Biomechanical comparison of tension band suture fixation and tension band wiring in olecranon fractures.
Vesterby L; Haugaard AM; Adjal J; Muhudin HI; Sert K; Thomsen MG; Ban I; Ohrt-Nissen S
Injury; 2023 Aug; 54(8):110919. PubMed ID: 37441859
[TBL] [Abstract][Full Text] [Related]
9. The effect of Ding's screws and tension band wiring for treatment of olecranon fractures: a biomechanical study.
Zhao Y; Tian H; Yin N; Du L; Pan M; Ding L
Sci Rep; 2024 May; 14(1):9999. PubMed ID: 38693300
[TBL] [Abstract][Full Text] [Related]
10. Biomechanical comparison of tension band wiring and plate fixation with locking screws in transverse olecranon fractures.
Midtgaard KS; Søreide E; Brattgjerd JE; Moatshe G; Madsen JE; Flugsrud GB
J Shoulder Elbow Surg; 2020 Jun; 29(6):1242-1248. PubMed ID: 32139286
[TBL] [Abstract][Full Text] [Related]
11. Biomechanical Comparison of Olecranon Sled Versus Intramedullary Screw Tension Banding for Olecranon Osteotomies.
Kia C; Dukas AG; Marshall ST; Voss A; Obopilwe E; Browner BD; Mazzocca AD
Orthop J Sports Med; 2018 Dec; 6(12):2325967118816075. PubMed ID: 30574518
[TBL] [Abstract][Full Text] [Related]
12. A new all-suture tension band tape fixation technique for simple olecranon fractures versus conventional tension band wire fixation: a comparative biomechanics study.
Ernstbrunner L; Rupasinghe HS; Almond M; Jo OI; Zbeda RM; Oppy A; Treseder T; Pullen C; Ek ET; Ackland DC
J Shoulder Elbow Surg; 2022 Jul; 31(7):1376-1384. PubMed ID: 35167913
[TBL] [Abstract][Full Text] [Related]
13. Olecranon fractures: A biomechanical comparison of three tension band wiring fixation methods on bone models.
Calisal E; Uğur L
J Orthop Surg (Hong Kong); 2023; 31(3):10225536231223109. PubMed ID: 38115708
[TBL] [Abstract][Full Text] [Related]
14. Is intramedullary screw fixation biomechanically superior to locking plate fixation and/or tension band wiring in transverse olecranon fractures? A cadaveric biomechanical comparison study.
Hahn A; O'Hara NN; Koh K; Zhang LQ; O'Toole RV; Andrew Eglseder W
Injury; 2020 Apr; 51(4):850-855. PubMed ID: 32173084
[TBL] [Abstract][Full Text] [Related]
15. Evaluation of methods of internal fixation of transverse patella fractures: a biomechanical study.
Burvant JG; Thomas KA; Alexander R; Harris MB
J Orthop Trauma; 1994; 8(2):147-53. PubMed ID: 8207572
[TBL] [Abstract][Full Text] [Related]
16. [A biomechanical study on internal fixation of proximal ulna combined with olecranon fracture].
Teng L; Zhong G; Liu G; Xiao C; Liu G; Huang F
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2012 Jan; 26(1):10-3. PubMed ID: 22332509
[TBL] [Abstract][Full Text] [Related]
17. Biomechanical analysis of tension band fixation for olecranon fracture treatment.
Kozin SH; Berglund LJ; Cooney WP; Morrey BF; An KN
J Shoulder Elbow Surg; 1996; 5(6):442-8. PubMed ID: 8981269
[TBL] [Abstract][Full Text] [Related]
18. Tension band wiring of the olecranon: is it really a dynamic principle of osteosynthesis?
Brink PR; Windolf M; de Boer P; Brianza S; Braunstein V; Schwieger K
Injury; 2013 Apr; 44(4):518-22. PubMed ID: 23062670
[TBL] [Abstract][Full Text] [Related]
19. [Treatment of isolated fractures of the olecranon: percutaneous double-screw fixation versus conventional tension band wiring].
Uhlmann M; Barg A; Valderrabano V; Weber O; Wirtz DC; Pagenstert G
Unfallchirurg; 2014 Jul; 117(7):614-23. PubMed ID: 23754551
[TBL] [Abstract][Full Text] [Related]
20. Dynamic biomechanical analysis of different olecranon fracture fixation devices--tension band wiring versus two intramedullary nail systems: an in-vitro cadaveric study.
Nowak TE; Mueller LP; Burkhart KJ; Sternstein W; Reuter M; Rommens PM
Clin Biomech (Bristol, Avon); 2007 Jul; 22(6):658-64. PubMed ID: 17449153
[TBL] [Abstract][Full Text] [Related]