These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

76 related articles for article (PubMed ID: 12730922)

  • 1. Instrumentation pitfalls: you just can't go on autopilot!
    Laskin RS
    J Arthroplasty; 2003 Apr; 18(3 Suppl 1):18-22. PubMed ID: 12730922
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Rotational alignment of femoral component with computed-assisted surgery (CAS) during total knee arthroplasty].
    Michaut M; Beaufils P; Galaud B; Abadie P; Boisrenoult P; Fallet L
    Rev Chir Orthop Reparatrice Appar Mot; 2008 Oct; 94(6):580-4. PubMed ID: 18929753
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Geometric analysis of potential error in using femoral intramedullary guides in total knee arthroplasty.
    Novotny J; Gonzalez MH; Amirouche FM; Li YC
    J Arthroplasty; 2001 Aug; 16(5):641-7. PubMed ID: 11503125
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Improved tibial cutting accuracy in knee arthroplasty.
    Macdonald W; Styf J; Carlsson LV; Jacobsson CM
    Med Eng Phys; 2004 Nov; 26(9):807-12. PubMed ID: 15564118
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Determining the rotational alignment of the femoral component in total knee arthroplasty using the epicondylar axis.
    Berger RA; Rubash HE; Seel MJ; Thompson WH; Crossett LS
    Clin Orthop Relat Res; 1993 Jan; (286):40-7. PubMed ID: 8425366
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Seven cuts to the perfect total knee.
    Brooks P
    Orthopedics; 2009 Sep; 32(9):. PubMed ID: 19751004
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The extramedullary guide of the proximal tibia resection should be seen straight in front during total knee arthroplasty.
    Nagamine R; Matsunobu T; Takayama M; Miura H; Matsuda S; Iwamoto Y
    Fukuoka Igaku Zasshi; 2006 May; 97(5):146-52. PubMed ID: 16898636
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Alignment of resection planes in total knee replacement obtained with the conventional technique, as assessed by a modern computer-based navigation system.
    Belvedere C; Ensini A; Leardini A; Bianchi L; Catani F; Giannini S
    Int J Med Robot; 2007 Jun; 3(2):117-24. PubMed ID: 17619241
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [A cadaveric study of relationships among rotational alignment reference axes of distal femur and tibial mechanical axis].
    Zhao BH; Chen BC; Shao DC; Wang F; Gao SJ; Lu B
    Zhonghua Wai Ke Za Zhi; 2008 Jul; 46(14):1085-7. PubMed ID: 19094537
    [TBL] [Abstract][Full Text] [Related]  

  • 10. "Grand piano sign," a marker for proper femoral component rotation during total knee arthroplasty.
    Moyad TF; Hughes RE; Urquhart A
    Am J Orthop (Belle Mead NJ); 2011 Jul; 40(7):348-52. PubMed ID: 22013571
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A navigated 8-in-1 femoral cutting guide for total knee arthroplasty technical development and cadaveric evaluation.
    Kendoff DO; Moreau-Gaudry A; Plaskos C; Granchi C; Sculco TP; Pearle AD
    J Arthroplasty; 2010 Jan; 25(1):138-45. PubMed ID: 19106033
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The variability of intramedullary alignment of the femoral component during total knee arthroplasty.
    Mihalko WM; Boyle J; Clark LD; Krackow KA
    J Arthroplasty; 2005 Jan; 20(1):25-8. PubMed ID: 15660056
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Intramedullary versus extramedullary tibial alignment guides in total knee arthroplasty.
    Yang SH; Liu TK
    J Formos Med Assoc; 1998 Aug; 97(8):564-8. PubMed ID: 9747068
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Bone landmarks are more reliable than tensioned gaps in TKA component alignment.
    Hanada H; Whiteside LA; Steiger J; Dyer P; Naito M
    Clin Orthop Relat Res; 2007 Sep; 462():137-42. PubMed ID: 17563704
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Linkage guide for rotational alignment during total knee arthroplasty.
    Yamada K; Imaizumi T; Takada N
    J Orthop Sci; 2003; 8(5):643-7. PubMed ID: 14557929
    [TBL] [Abstract][Full Text] [Related]  

  • 16. [Total knee arthroplasty by lateral parapatellar approach for valgus knee].
    Zhou DG; Zhang B; Kou BL; Lü HS
    Zhonghua Yi Xue Za Zhi; 2007 Jul; 87(27):1885-9. PubMed ID: 17923009
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Bone morphing system for rotational alignment in total knee arthroplasty].
    Wu H; van Driessche S; Goutallier D
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2008 Jan; 22(1):12-5. PubMed ID: 18361228
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Relationship between anatomy of knee collateral ligament and geometry of posterior femoral condylar articular surface].
    Zhou D; Lv H; Fang J
    Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2006 Jun; 20(6):594-7. PubMed ID: 16827379
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Total knee arthroplasty using computer-assisted navigation in patients with deformities of the femur and tibia.
    Klein GR; Austin MS; Smith EB; Hozack WJ
    J Arthroplasty; 2006 Feb; 21(2):284-8. PubMed ID: 16520220
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The effect of posterior tibial slope on range of motion after total knee arthroplasty.
    Kansara D; Markel DC
    J Arthroplasty; 2006 Sep; 21(6):809-13. PubMed ID: 16950031
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 4.