These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

381 related articles for article (PubMed ID: 12731600)

  • 1. Three-dimensional analysis of dual-arch impression trays.
    Cayouette MJ; Burgess JO; Jones RE; Yuan CH
    Quintessence Int; 2003 Mar; 34(3):189-98. PubMed ID: 12731600
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of a reformulated fast-set vinyl polysiloxane impression material using dual-arch trays.
    Kang AH; Johnson GH; Lepe X; Wataha JC
    J Prosthet Dent; 2009 May; 101(5):332-41. PubMed ID: 19410067
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Dimensional accuracy of dental casts: influence of tray material, impression material, and time.
    Thongthammachat S; Moore BK; Barco MT; Hovijitra S; Brown DT; Andres CJ
    J Prosthodont; 2002 Jun; 11(2):98-108. PubMed ID: 12087547
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The effects of custom tray material on the accuracy of master casts.
    Shafa S; Zaree Z; Mosharraf R
    J Contemp Dent Pract; 2008 Sep; 9(6):49-56. PubMed ID: 18784859
    [TBL] [Abstract][Full Text] [Related]  

  • 5. The effect of using custom or stock trays on the accuracy of gypsum casts.
    Rueda LJ; Sy-Muñoz JT; Naylor WP; Goodacre CJ; Swartz ML
    Int J Prosthodont; 1996; 9(4):367-73. PubMed ID: 8957875
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy of casts generated from dual-arch impressions.
    Breeding LC; Dixon DL
    J Prosthet Dent; 2000 Oct; 84(4):403-7. PubMed ID: 11044846
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy of complete dental arch impressions and stone casts using a three-dimensional measurement system. Effects on accuracy of rubber impression materials and trays.
    Ishida K
    Dent Jpn (Tokyo); 1990; 27(1):73-9. PubMed ID: 2099294
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Accuracy of second pour casts using dual-arch impressions.
    Schwartz RS; Davis RD
    Am J Dent; 1992 Aug; 5(4):192-4. PubMed ID: 1290607
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Dimensional accuracy of resultant casts made by a monophase, one-step and two-step, and a novel two-step putty/light-body impression technique: an in vitro study.
    Caputi S; Varvara G
    J Prosthet Dent; 2008 Apr; 99(4):274-81. PubMed ID: 18395537
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Effect of subgingival depth of implant placement on the dimensional accuracy of the implant impression: an in vitro study.
    Lee H; Ercoli C; Funkenbusch PD; Feng C
    J Prosthet Dent; 2008 Feb; 99(2):107-13. PubMed ID: 18262011
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Clinical trial investigating success rates for polyether and vinyl polysiloxane impressions made with full-arch and dual-arch plastic trays.
    Johnson GH; Mancl LA; Schwedhelm ER; Verhoef DR; Lepe X
    J Prosthet Dent; 2010 Jan; 103(1):13-22. PubMed ID: 20105676
    [TBL] [Abstract][Full Text] [Related]  

  • 12. The effect of impression volume and double-arch trays on the registration of maximum intercuspation.
    Hahn SM; Millstein PL; Kinnunen TH; Wright RF
    J Prosthet Dent; 2009 Dec; 102(6):362-7. PubMed ID: 19961994
    [TBL] [Abstract][Full Text] [Related]  

  • 13. An evaluation of three implant level impression techniques for single tooth implant.
    Daoudi MF; Setchell DJ; Searson LJ
    Eur J Prosthodont Restor Dent; 2004 Mar; 12(1):9-14. PubMed ID: 15058176
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Implant cast accuracy as a function of impression techniques and impression material viscosity.
    Walker MP; Ries D; Borello B
    Int J Oral Maxillofac Implants; 2008; 23(4):669-74. PubMed ID: 18807563
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Accuracy of open tray implant impressions: an in vitro comparison of stock versus custom trays.
    Burns J; Palmer R; Howe L; Wilson R
    J Prosthet Dent; 2003 Mar; 89(3):250-5. PubMed ID: 12644799
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of 2 impression techniques for ITI implants.
    Akça K; Cehreli MC
    Int J Oral Maxillofac Implants; 2004; 19(4):517-23. PubMed ID: 15346748
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Digitization of simulated clinical dental impressions: virtual three-dimensional analysis of exactness.
    Persson AS; Odén A; Andersson M; Sandborgh-Englund G
    Dent Mater; 2009 Jul; 25(7):929-36. PubMed ID: 19264353
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of a new ring-opening metathesis elastomeric dental impression material with spray and immersion disinfection.
    Kronström MH; Johnson GH; Hompesch RW
    J Prosthet Dent; 2010 Jan; 103(1):23-30. PubMed ID: 20105678
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dual-arch and custom tray impression accuracy.
    Davis RD; Schwartz RS
    Am J Dent; 1991 Apr; 4(2):89-92. PubMed ID: 1854447
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The use of a 3D laser scanner using superimpositional software to assess the accuracy of impression techniques.
    Shah S; Sundaram G; Bartlett D; Sherriff M
    J Dent; 2004 Nov; 32(8):653-8. PubMed ID: 15476960
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 20.